24 — The frontier

What changes next, and what does not.

+ The questionWhat will change in omics over the next decade, and what is still unsolved?

A rule for reading the future

On 8 October 2026 a developer of single-molecule protein sequencing announced that it had detected 19 of the 20 amino acids in its development program, three weeks after announcing 18 with a developmental kit (Chapter 9). Both announcements were the company's own statements about work in development. Claims about the future of omics arrive faster than evidence, and they look alike: a press release announcing a shipment reads much like one announcing a plan.

The most useful habit this chapter can offer is therefore a sorting rule. For any claim, the first question is which of four columns it belongs in: in routine use; available and in early use; demonstrated in research; or announced, projected or under review. The claim is then read with the evidence that column carries, and the plate below applies the rule to the developments discussed in this guide, as of October 2026.

50 — Demonstrated, available, announced
ROUTINE USE short-read genome and exome sequencing cfDNA prenatal screening newborn screening by tandem MS clinical MS assays AVAILABLE, EARLY USE long-read clinical sequencing — Class III registration in China, 2025, described by its maker as the first clearance spatial whole-transcriptome imaging blood-based colorectal cancer screening (FDA-approved 2016, 2024 and 2026) 5-base sequencing (2025): DNA + methylation in one read single-cell at millions of cells DEMONSTRATED IN RESEARCH nanopore telling apart synthetic protein strands single-EV multiplexed profiling multi-omics integration at cohort scale ANNOUNCED OR IN REVIEW multi-cancer blood test (PMA under FDA review, Oct 2026) single-molecule protein sequencing: 19 of 20 amino acids announced in October 2026 population proteomics of 600,000 samples (full data expected 2027) AI ‘virtual cell’ models — did not beat simple baselines in 2025 benchmarks published evidence to the left, announcements to the right
DNARNAProteinMetaboliteModificationFocal detail
Plate 50 — Much of what is called the future of omics is already routine; much of what is announced is not yet shown. Reading a claim well starts with placing it in the right column.

Sequencing: cheaper, longer, and read with its marks

The cost of reading DNA is likely to keep falling, though the easy gains have probably been taken (Chapter 5 traces the fall so far). The remaining costs are likely to lie increasingly in sample handling, analysis, storage and interpretation rather than in reagents. The larger changes are in what a read contains. Long reads are entering the clinic: in November 2025 a sequencer maker announced that its long-read system had received a Class III registration in China, the country's class for the highest-risk devices. The registration covers testing for thalassemia, an inherited blood disorder, and the maker called that registration the first regulatory clearance of a clinical long-read sequencer.

Methods that report methylation and sequence from the same library, launched in 2025, have begun to make the epigenome a by-product of reading the genome (Chapter 6). Pangenome references are beginning to supplement single references (Chapter 4). Population programs now include more than ten thousand long-read genomes alongside hundreds of thousands of short-read ones.

Proteins: population scale, and single molecules

Protein measurement is where the next decade will change most, because it starts furthest behind. Population proteomics will move from tens of thousands to hundreds of thousands of people, with the full data of the UK Biobank expansion expected in 2027 (Chapter 9). Mass spectrometers keep gaining speed, and the makers of the separation and sample-preparation systems that feed them report throughputs of hundreds of samples a day (Chapter 23). Single-molecule protein sequencing is the development to watch most carefully, because it attacks the limit set out in Chapter 2. It has moved from academic demonstration to shipping instruments with partial amino-acid coverage, and the 2026 announcements that open this chapter are development results. Reading a plasma proteome molecule by molecule, at depth and at cost, remains a goal rather than a result.

New platforms move physical limits more often than they remove them

It is tempting to treat every limit in omics as temporary, waiting for a better instrument, and some are. But copying and pairing, dynamic range, detection limits, the multiple-testing burden and the gap between association and utility are properties of molecules, samples and statistics, so new platforms move these limits, sometimes a long way, but rarely abolish them. A claim that one has should be read with that in mind.

Cells at atlas scale, and the models trained on them

Single-cell experiments have reached the scale of atlases. In October 2024 one maker stated that its droplet system can profile up to 2.5 million cells in a run, and a company's 2025 preprint described a dataset of about 100 million cells from 50 cancer cell lines exposed to drugs (Chapter 12). Much of that scale is being spent on perturbation atlases, which measure systematically how cells respond when each gene is switched off or each drug is applied. Spatial methods are converging on whole-transcriptome coverage at cellular resolution, and on measuring RNA, protein and chromatin in the same section. The limiting factors are shifting from chemistry to segmentation, the drawing of each cell's boundary in an image, and to data volume and cost per tissue area.

Machine learning has already changed one part of molecular biology decisively: protein structure prediction, which in 2024 was extended to complexes of proteins with nucleic acids and small molecules. One such model, AlphaFold 3, was described that year by Abramson and colleagues, who worked at Google DeepMind and Isomorphic Labs, the two companies that built it. Models that read long stretches of DNA sequence and predict regulatory activity, or score the likely effect of a variant, were published in 2025 and 2026. Google DeepMind described one of them, AlphaGenome, in a preprint in June 2025 and in Nature in January 2026. It reads up to a million bases at once and predicts about 5,900 human genomic signals, such as gene expression and splicing, and its authors report that it matched or beat earlier models in 25 of 26 tests of variant effects. Another, Evo 2, built by the Arc Institute with Stanford University and NVIDIA among others, was trained on 9.3 trillion DNA bases, and its authors report that it predicts the effects of variants without being trained for that task.

A more ambitious goal is a "virtual cell", a model that predicts how any cell will respond to any perturbation, and it is announced rather than demonstrated. Independent benchmarks published in 2025 found that several large single-cell foundation models, models trained on many single-cell datasets at once, did not outperform simple linear baselines at predicting the effects of genetic perturbations. In one of those benchmarks, Ahlmann-Eltze, Huber and Anders tested five such models and two other deep-learning models on how the transcriptome changes after one or two genes are perturbed, and none beat the deliberately simple baselines. The three were academic researchers at EMBL and Heidelberg University when they published the benchmark.

The Arc Institute ran its first Virtual Cell Challenge as an open competition on the same task, with sponsorship from companies that include makers of single-cell and sequencing instruments. Teams predicted how human embryonic stem cells respond when single genes are knocked out, and when the winners were announced in December 2025, the winning models did not beat naive baselines on every metric either.

The 2025 results suggest that the binding constraint is data designed to answer the question rather than model size, which is why the perturbation atlases above matter. In October 2026 Shift Bioscience, a company that builds virtual-cell models, announced a study published with collaborators in Nature Biotechnology. The company stated that deep-learning models that predict the effects of perturbations can beat uninformative baselines once the metrics are calibrated, although a simple additive baseline remained hard to beat on the dataset with the fewest gene combinations in its training data.

Solved example: how much of the question one challenge covered

The Arc Institute's first Virtual Cell Challenge gave teams a dataset of 300,000 cells and 300 gene knockouts, all in one line of human embryonic stem cells. Dividing 300,000 cells by 300 knockouts gives about 1,000 cells measured for each knockout. Chapter 1 puts the number of human genes that encode proteins at roughly 20,000, and 300 knockouts amount to 1.5 % of that number, about one gene in seventy. A model that predicted every response in the challenge would therefore have shown its skill on about one gene in seventy and in one kind of cell, while a virtual cell is meant to cover any gene in any cell.

51 — What one challenge measured
ABOUT 20,000 PROTEIN-CODING GENES · EACH SQUARE 100 GENES 300 knockouts 1.5 % of the genes, about 1 in 70 300,000 cells / 300 knockouts = about 1,000 cells per knockout one cell type: H1 human embryonic stem cells challenge figures from the Arc Institute (June 2025); the gene count is a round figure; layout schematic
ReadoutFocal detail
Plate 51 — The first Virtual Cell Challenge measured about 1,000 cells for each of 300 knockouts, in one cell type: 300 knockouts are about 1.5 % of the genes a virtual cell would have to cover.

Liquid biopsy and vesicles

A blood test for many cancers at once is under review at the FDA, and its evidence will set the terms for the field. In May 2026 its maker presented the results of a randomized trial of the test among about 142,000 adults in England, and in September 2026 the trial's investigators published them in The New England Journal of Medicine. The trial missed its primary endpoint, a lower incidence of stage III or IV cancer. The rate of stage IV diagnoses, its key secondary endpoint, was 14 % lower in the screened group, but the confidence interval around that result reached the value that means no difference (Chapter 22). The maker funded the trial, and three of the paper's 13 authors were affiliated with the maker. As of October 2026 the FDA's decision on the test is pending (Chapter 25).

EV-based diagnostics are advancing more slowly, and the obstacle is largely metrological, a problem of measurement science, as Chapter 14 argued: calibrated detection limits, reference materials and reporting standards. Until all three are in place, counts of vesicles from different laboratories cannot be compared, whatever the biomarker.

What still needs to be solved

Most of the limits described in this guide are physical or statistical, rather than engineering problems waiting for the next platform, and naming them is the most durable part of any forecast.

  • The protein dynamic range. Protein concentrations in plasma span about ten orders of magnitude, and proteins can be neither copied nor read by pairing (Chapter 2). Enrichment, affinity and single-molecule methods each move the limit, but none has removed it.
  • Metabolite identification. One reanalysis of untargeted datasets from blood estimated that more than half of the compounds detected with high confidence are still unknown (Chapter 10).
  • Reproducibility across laboratories. Batch effects, platform differences and unreported processing choices still stop many results from transferring between sites (Chapter 18).
  • Detection limits for particles. Vesicle and nanoparticle measurements need calibrated, stated detection limits before their counts can be compared (Chapter 14).
  • Diversity of reference data. Variant interpretation remains weakest for populations underrepresented in reference cohorts, including many in South Asia (Chapter 4).
  • From validity to utility. Many signatures have analytical and clinical validity, and far fewer have evidence that acting on them improves outcomes (Chapter 22).
  • Interpretation and privacy. A 2015 review expected the cost of interpreting variants to fall more slowly than the cost of generating the sequence, so that the two would become comparable. In two hospital costing studies of genome sequencing, one from the United Kingdom published in 2019 and one from Canada published in 2020, sequencing reagents and other supplies made up the largest share of the cost, and neither study costed genetic counseling. Reagent prices have fallen since (Chapter 5). Genomic data also raise privacy questions that outlast any single study.
In practice

Write down the column and the evidence of every claim, the team's own included: routine, with guidelines and payment; available, with early users; demonstrated, with a publication; or announced, with a date. Keep the four apart in proposals, marketing and technical files. A reader who finds demonstrated and projected claims stated apart can check each against its own evidence.

+ What this chapter established
  • Every claim can be sorted into routine, available, demonstrated or announced, and weighed by its column.
  • Sequencing gains are shifting from cost to content: long reads, methylation read with the sequence, pangenomes.
  • Protein measurement will change most, with population scale now and single-molecule methods still emerging.
  • The hardest limits are physical and statistical, and platforms move them more often than they remove them.