Memory without changing the letters.
+ The questionHow does a cell remember what it is when its sequence never changes?
Identity has to survive division
When a sequencer that copies DNA reads the genome of a liver cell and of a neuron from the same person, it reports the same letters for both. It also misses the chemical marks on the DNA that tell the two cells apart, because the enzyme that copies DNA before sequencing copies a marked base as an ordinary one. Yet when a liver cell divides, both daughters are liver cells. The sequence was copied, but since the same sequence also makes a neuron, something else must have been copied too: the record of which genes this cell keeps available and which it keeps silent.
That record is the epigenome, from the Greek for "on top of" the genome. It consists of chemical marks and physical packaging that sit on the DNA without changing its letters, and that a dividing cell passes to its daughters. Three kinds of record matter most for measurement. The first is DNA methylation, a small methyl group attached to cytosine. In most cell types it sits almost always where a C is followed by a G, a site written CpG, and the human genome has about 28 million such sites. Neurons are a notable exception, carrying substantial methylation at other sites too.
Methylation is copied through division by an enzyme that reads the mark on the old strand and adds it to the new one, which is what makes it a memory. The second kind of record is chromatin accessibility. DNA is wound around the protein spools called nucleosomes (Chapter 1), and a gene wound tightly is hard for the transcription machinery to reach. The third is histone modification: chemical marks that recruit or repel the machinery, carried on the histones, the proteins that make up each spool. Together the three decide which parts of the genome a cell can read.
Methylation: turning a mark into a letter
Because the methyl mark is lost at the first copy made before sequencing, the classic methods convert the question into one a sequencer can answer. Bisulfite treatment chemically converts every unmethylated cytosine into uracil, which is copied as T, while methylated cytosines are protected and stay C. After sequencing, each CpG in each read shows either C, meaning it was methylated, or T, meaning it was not.
Bisulfite chemistry is harsh and fragments much of the DNA, which matters when the starting material is scarce, as with the cell-free DNA in blood described in Chapter 14. Enzymatic conversion methods do the same job with enzymes instead. In a 2021 bench comparison, Vaisvila and colleagues tested one enzymatic method against bisulfite on genomic DNA, cell-free DNA and DNA from preserved tissue, across a range of input amounts. All 20 authors worked for the company that sells the enzymatic kit, which also funded the study. The authors reported that the enzymatic method damaged the DNA less than bisulfite did and worked from as little as 100 pg of DNA.
Newer approaches read methylation alongside the ordinary sequence in one library, and long-read instruments detect methylated bases directly from the native molecule without any conversion (Chapter 5). The conversion methods share one built-in limit. Standard bisulfite and enzymatic conversion both protect a related mark, 5-hydroxymethylcytosine, as well as 5-methylcytosine, the ordinary methylated C, so they cannot tell the two marks apart without an extra chemical step.
The output of any of these methods is a methylation level: at each CpG, the fraction of reads that carried the mark. That fraction is a sampling estimate, and its precision depends on how many reads covered the site, because a fraction taken from 10 reads can move a long way by chance while a fraction taken from hundreds of reads moves much less.
At one CpG, 7 of 10 reads read C, so the methylation level is 7 divided by 10, or 70 %. The standard error of a proportion comes from three steps: the level times one minus the level, that product divided by the number of reads, and the square root of the result. Here 0.7 times 0.3 is 0.21, 0.21 divided by 10 is 0.021, and the square root of 0.021 is about 0.145. Multiplying by 1.96 for 95 % confidence gives roughly 70 % ± 28 points, and at so few reads even that simple interval is only a rough guide. With 100 reads the same calculation gives about ± 9 points. A difference between two samples at 60 % and 70 % methylation is therefore invisible at 10 reads and detectable at a few hundred.
A CpG measured at 50 % in a tissue can mean that every cell has one of its two copies methylated, that half the cells are fully methylated and half are not, or any mixture in between. Bulk measurements cannot tell these apart, and the difference is often the biology of interest, for example when a small population of tumor cells carries a pattern the surrounding tissue does not. Reading single molecules, as long reads do, or single cells, as Chapter 12 describes, is how the ambiguity is resolved.
Accessibility: an enzyme does the measuring
Accessibility is measured by asking an enzyme to find it. In 2013 Buenrostro and colleagues at Stanford University introduced ATAC-seq. The method loads an engineered transposase, an enzyme that inserts DNA, with sequencing adapters. Added to cell nuclei, the transposase can reach only DNA that is not wrapped around nucleosomes or covered by other proteins, and wherever it can reach, it cuts the DNA and inserts adapters in the same step. When the resulting fragments are sequenced and stacked on the genome, they form peaks where the chromatin was open: at active promoters, where a gene's transcription starts, at enhancers, which raise a gene's activity from a distance, and at other regulatory switches.
ATAC-seq is a clear case of the measuring-by-proxy principle of Chapter 3. Nobody observes chromatin opening. What is counted is where an enzyme was able to act, and the inference is that those regions were available to the cell's own machinery too.
Marks on the spools, and the fold
Histone modifications are read with antibodies. In chromatin immunoprecipitation followed by sequencing, or ChIP-seq, the laboratory cross-links the chromatin, chemically fixing proteins to the DNA they touch, then fragments it, pulls it down with an antibody against a particular mark and sequences the recovered DNA. In 2019 Kaya-Okur and colleagues at the Fred Hutchinson Cancer Research Center published CUT&Tag, which instead uses the antibody to guide the adapter-inserting enzyme to the mark. They profiled one histone mark from as few as 60 cells, far fewer than ChIP-seq needs. Both methods inherit the strengths and weaknesses of binding: they find exactly the mark the antibody recognizes, and they are only as specific as the antibody.
The genome also has a three-dimensional shape, and regulatory switches often act on genes far away along the sequence but close in space. Chromosome conformation methods measure that shape. Lieberman-Aiden and colleagues at the Broad Institute and the University of Massachusetts Medical School introduced Hi-C in 2009. In Hi-C the laboratory cross-links DNA that is touching in the nucleus, cuts it, joins the cut ends that the cross-links hold together and sequences the junctions. The frequency of each junction shows how often two distant regions sit together.
Why methylation reaches beyond the cell
Methylation patterns differ between tissues and change in disease, and they survive in DNA fragments after cells die, which makes them useful far from the cell they came from. Each fragment of DNA in the blood carries the methylation of the tissue that released it. The methylation of many fragments read together is the basis of methods that estimate which tissues cell-free DNA came from, and of blood tests that look for the methylation signatures of cancer, patterns across many sites that mark the disease (Chapter 14).
Methylation at certain sites also changes steadily with age, and statistical models built on those sites, often called epigenetic clocks, estimate age from a blood sample. In 2013 Horvath, at the University of California, Los Angeles, published a clock that combines 353 sites and works across most tissues and cell types. He built and tested it on about 8,000 samples from 82 public methylation data sets, and in the test data its estimates had a median error of 3.6 years. As a competing interest, the paper declares a provisional patent application owned by the University of California, with Horvath as inventor. A clock gives an estimate, not a direct measurement of biological age.
Conversion-based methods need proof that conversion worked. Specify a control with a known answer, typically unmethylated DNA added to every sample, and an acceptance criterion for conversion, because incomplete conversion reads as false methylation. The ENCODE consortium's standard for whole-genome bisulfite sequencing, for example, asks for a conversion rate of at least 98 %. The consortium last updated that standard in June 2017, and as of October 2026 that version is still current. For low-input material such as cell-free DNA, weigh enzymatic conversion or direct long-read detection against bisulfite, and state the minimum read depth per CpG that the decision needs.
- The epigenome records which parts of the genome a cell keeps available, and the cell copies that record through division.
- The copying that sequencing relies on loses methylation, so methods either convert it into a letter a sequencer can read or read it from the native molecule.
- Accessibility is measured by where an enzyme can reach, and histone marks by where an antibody binds.
- A methylation level is a population fraction at one site, and its precision depends on read depth.
Let's Talk