+ Part I · Foundations
What the genome cannot tell.
At typical levels in the plasma of a healthy adult, each molecule of the signaling protein interleukin-6 is outnumbered by about 2.5 billion molecules of albumin, and unlike a molecule of DNA, the rare protein cannot be copied to make it easier to find. This part builds the model that the later chapters rely on: why one genome can produce cells as different as a neuron and a liver cell, why DNA and RNA can be copied and recognized by pairing while proteins and metabolites cannot, and which few physical properties omics instruments read. Nothing in it assumes more than school biology.
One genome, many cell types.
+ The questionIf a neuron and a liver cell carry identical DNA, what makes them different?
The instruction set and the state
A human cell carries two copies of its genome, one inherited from each parent, and each copy is about 3.1 billion base pairs long. Somewhere around 20,000 stretches of that sequence are genes that encode proteins. Their protein-coding portions occupy less than 1.5 % of the total, and the rest includes the switches, spacers and structural sequence that control when and where those genes are used. With a handful of exceptions, every nucleated cell in the body carries essentially the same sequence. The exceptions are instructive rather than fatal to the rule: red blood cells discard their nucleus, immune cells cut and rejoin their receptor genes, eggs and sperm carry one copy instead of two, and every dividing cell slowly accumulates a few new mutations. None of these explains why a neuron is a neuron.
Direct evidence that a specialized cell can keep the information for other cell types came from frogs. At the Department of Zoology in Oxford, John Gurdon took nuclei from the cells lining the intestine of feeding tadpoles of Xenopus laevis and transplanted each one into an egg whose own nucleus had been destroyed by irradiation. Gurdon began the work as a graduate student of Michail Fischberg and published it in 1962. The donor cells were visibly specialized, with what his paper called "the striated border typical of cells having an absorptive function". Of 726 eggs in the first round of transfers, 10 grew into normal feeding tadpoles, and a genetic marker proved that those tadpoles had developed from the transplanted nucleus.
Ten tadpoles from 726 transfers is a small yield, and Gurdon stated his conclusion with care: the differentiation of a cell "cannot be dependent upon the incapacity of its nucleus to give rise to other types of differentiated cell". A nucleus taken from a cell built to absorb food still held what was needed to build a swimming, feeding tadpole, so the donor had kept the information for the whole animal, and what made it an intestinal cell was not written in its sequence. The experiment could not show where the difference was recorded, and each layer that omics measures is one place to look for it.
What differs between cells is which parts of the genome they use. A neuron is long, electrically excitable and packed with ion channels, while a liver cell is compact, stuffed with enzymes that detoxify drugs and make blood proteins, and has no use for an axon. Biologists count a few hundred distinct cell types in the human body, and every one of them is a different selection from the same genome. The genome is the instruction set: it constrains what a cell can become. What the cell actually is at a given moment is its state: which instructions it is using, how intensely, and with what result. Two cells with identical genomes can be in radically different states, and one cell can change state within minutes.
Reading is regulated at every step
The route from instruction to function has several steps, and the cell controls each one. DNA is packed around protein spools called nucleosomes, and chemical marks on the DNA and on the spools decide whether a gene is accessible at all. An accessible gene can be copied into RNA, a process called transcription, at a rate the cell sets. The RNA is edited, exported and eventually destroyed, and its lifetime is regulated too. A messenger RNA is read by a ribosome to build a protein, a process called translation, again at a controllable rate.
Biologists say that a gene is expressed when it is transcribed, and they usually measure its expression as the amount of its RNA, or of the protein made from it. The finished protein may be cut, folded, decorated with phosphate groups or sugars, sent out of the cell, or degraded. Many proteins are enzymes, and their activity determines which small molecules, the metabolites, are made and consumed.
Every one of those control points is a place where information enters that was not present in the step before. An accessible gene may be transcribed slowly or fast, so knowing that it is accessible does not reveal how much RNA is being made from it. The RNA level does not reveal how much protein exists, because translation rates and protein lifetimes vary by orders of magnitude between genes. The amount of an enzyme does not reveal how much chemistry it is doing either, because enzymes are switched on and off by modification and by the metabolites around them. These control points give the first answer to the central question. Each layer downstream of the genome records a decision the cell has made, and that decision is not written in the sequence.
A genome sets what a cell can do and what it is predisposed to, but it does not record what the cell is doing. Every other omics layer is a way of reading some part of that state.
Omics measures a whole set at once
The suffix -ome means the complete set: the genome is all of an organism's DNA sequence, and the proteome all of its proteins. Omics is the practice of measuring an entire set at once instead of one member at a time. An assay is a laboratory test for a substance in a sample, and a classical assay measures one substance at a time, so it asks a narrow question, such as how much of one protein a sample holds. An omics experiment asks a wide one, such as which of the thousands of proteins in a sample differ between two groups.
The width is both the strength and the cost. Measuring everything at once lets a study find molecules that no one knew to look for. A biomarker is a molecule whose level indicates a state of the body, such as a disease or a response to treatment, and many candidate biomarkers are now first found this way. But an instrument that measures twenty thousand things in one run cannot optimize itself for any one of them. Each individual measurement is typically less precise than a dedicated assay would be, and with twenty thousand measurements some will look interesting by chance alone. Both costs return later in this guide, the first in the chapters on individual layers and the second in Chapter 18.
Each layer changes at its own rate
The layers also differ in how fast they change, and that matters as much as what they record. The inherited sequence is fixed for life. Epigenetic marks range from modifications of the spool proteins, the histones, that can change within minutes to DNA methylation patterns that persist for years, and many are copied through cell division. Messenger RNAs in mammalian cells have lifetimes measured in hours, and proteins last longer. In a 2011 study at the Max Delbrück Center in Berlin, Schwanhäusser and colleagues labeled newly made RNA and protein in one line of mouse fibroblasts, a kind of connective-tissue cell, and measured the turnover of both for more than 5,000 genes. They found a median half-life, the time in which half of the molecules present are destroyed, of about 9 hours for messenger RNA and 46 hours, about two days, for protein. Many metabolites turn over in seconds to minutes.
The calculation takes the medians of Schwanhäusser and colleagues, about 9 hours for messenger RNA and 46 hours for protein, and assumes that every molecule has the same chance of being destroyed in each hour, which is what a single half-life implies. One day of 24 hours is about 2.7 half-lives for the median RNA. Two half-lives, 18 hours, leave a quarter of it and three, 27 hours, leave an eighth, so after 24 hours between an eighth and a quarter is left, and the exact calculation puts it at about 16 %. For the median protein, half of one half-life, 23 hours, leaves about 71 %, because two such halves make a whole half-life and 0.71 × 0.71 is about 0.5. Twenty-four hours is slightly longer, so a little under 71 %, about 70 %, of the protein is left. Within one day the median RNA is mostly replaced, while most of the median protein is still the protein that was present the day before.
Each layer therefore records a different span of time, much as a camera records a different interval at each shutter speed. The transcriptome reflects the last few hours of the cell's decisions, and the metabolome the last few minutes of its chemistry. That difference has an immediate practical consequence, because the faster a layer changes, the more it can change after the sample is taken. A blood tube left on a bench keeps metabolizing, and cells under stress during tissue collection start changing their RNA before anyone measures it. The further a layer sits from the genome, the more the handling of the sample becomes part of the result.
Before choosing a technology, name the layer that carries the signal the question needs. A question about susceptibility or inherited risk is a genome question. A question about what a tissue is doing now is a transcriptome, proteome or metabolome question, and it brings a sample-handling requirement with it: time to freeze, temperature, anticoagulant and storage. Those conditions belong in the protocol and the specification from the first draft, not as a later fix.
Twins as an experiment with the genome held constant
The design of the NASA Twins Study rests on the distinction between instruction set and state. One of a pair of identical twins spent 340 days aboard the International Space Station while his brother stayed on Earth, and research teams measured most of the molecular layers this guide covers in both men. Identical twins arise from a single fertilized egg, so the brother on the ground served as a genetically matched control. The pair is close to an ideal experiment for this guide's question, because the inherited genome is held constant. A difference between the twins, or between one twin before and after flight, therefore points to another layer, unless it is one of the few changes in DNA that cells acquire during life. Chapter 15 sets out the study's design and those acquired changes, and reads its results layer by layer once the guide has built the tools to interpret them.
The 7 % figure at the center of the opening came from this study's preliminary results. The inherited sequence had not changed: what had shifted, and in part stayed shifted, was the expression of a set of genes. Reading that change in state as a change in the code is the confusion this chapter exists to prevent.
- Nearly every cell carries the same genome, and Gurdon's frog experiments showed that a cell does not become specialized by losing the information for other cell types; cell types differ in which parts of the genome they use.
- Each step from DNA to function is regulated, so each layer carries information the previous one does not.
- Omics measures a whole layer at once, trading per-molecule precision for the chance to find the unexpected.
- Layers change at very different speeds, so the faster ones make sample handling part of the measurement.
Let's Talk