+ Part II · The nucleic-acid layers

Reading by copying and pairing.

At the sequencing centers funded by the US National Human Genome Research Institute, the cost of producing a human genome sequence fell much faster once the centers moved to instruments that read millions of copied DNA fragments in parallel, and Chapter 5 gives the figures. The genome, the epigenome and the transcriptome can all be read on such instruments, because their molecules can be copied and recognized by pairing. This part shows how a genome is read in fragments and put back together against a reference, and why laboratories still run three generations of sequencer for three different questions. It then shows how chemistry and enzymes turn methylation into letters a sequencer can read, how an enzyme marks open chromatin for sequencing, and how counting the reads that land on each gene measures what a cell is using.

04 — Genomics

Reading a genome in fragments.

+ The questionHow are three billion letters read when no instrument reads a chromosome end to end?

Shatter, read, reassemble

Chromosome 1, the largest human chromosome, is a single DNA molecule about 250 million base pairs long. No sequencer reads anything close to that in one pass: the most common instruments read a few hundred bases at a time, and even the long-read machines described in Chapter 5 typically read tens of thousands. Every genome is therefore read the same way. The DNA is broken into pieces, an instrument reads the sequence of each piece, and software puts the pieces back in order. The sequence that an instrument reports for one piece is called a read.

The laboratory half of that process is called library preparation. A laboratory extracts DNA from cells, breaks it into fragments and fits each fragment with short synthetic sequences, called adapters, at both ends. The adapters are what the instrument grips and where the reading starts, so every fragment presents the same handle, whatever part of the genome it came from. The result is a library: hundreds of millions of fragments, each a random sample of the genome and each ready to be read.

The computational half turns the reads back into a genome. Most human sequencing uses alignment, in which software matches each read to the position it best fits in a reference genome, the agreed standard sequence that serves as a coordinate system. Where no suitable reference exists, software assembles the reads from scratch by finding the overlaps between them, the way a torn page can be reconstructed from overlapping scraps. Both approaches rely on the reads being long enough, and unique enough, to find their place.

Every base is read many times

A single read is not trusted, for two reasons. The first is error. Sequencers report a quality score for every base on a scale in which every 10 points is a tenfold step, so Q30 means an estimated one chance in a thousand that the base is wrong, and Q20 one chance in a hundred. Even at Q30, a genome read once would contain millions of errors. The second reason is sampling. Fragments land on the genome at random, so some positions are covered many times and some not at all, the same way raindrops leave some paving stones soaked and others dry.

The answer to both is coverage, the average number of reads covering each position. Genome laboratories also call it depth, a different sense of the word from that of Chapter 2, where depth is how scarce a molecule a method can still detect. A standard clinical or research genome is sequenced to about 30-fold coverage, written 30×. At that coverage, a position read by 28 reads, 14 showing one letter and 14 another, gives a confident call. A position that happens to be read by only 4 reads does not, which is why coverage is reported as a distribution and not just as an average.

Solved example: how many reads a 30× genome takes

The haploid human genome is about 3.1 billion bases long, so reading it to 30× coverage means reading 30 times that length, about 93 billion bases, or 9.3 × 10¹⁰. With reads of 150 bases each, 93 billion bases divided by 150 bases a read gives about 620 million reads. Instruments usually produce these reads in pairs, one from each end of a fragment, so a 30× genome takes about 310 million pairs. The total follows from three numbers, the genome's length, the coverage chosen and the read length, which means that doubling the coverage doubles the number of reads and doubling the read length halves it.

What a variant looks like in the data

Once the reads are stacked against the reference, differences stand out, and their pattern says what they are. A heterozygous variant, present on only one of the two parental copies of a chromosome, appears in roughly half the reads at that position, and a homozygous variant, present on both copies, appears in nearly all of them. A random sequencing error usually appears in one read and nowhere else, because such errors rarely repeat at the same position across independent fragments. Systematic errors can recur, for example in runs of a single base, in duplicated fragments or in reads misplaced in repeats. The software that makes the calls therefore also weighs duplicate reads and strand balance, which is whether the supporting reads come from both strands of the DNA. It also weighs mapping quality, the confidence with which each read was placed.

That is the logic of variant calling: a variant is a difference that recurs in many independent reads at the same position, at a proportion consistent with one or two copies. The software combines those checks with the number of supporting reads and their base qualities, and it reports each call with a confidence of its own. The output of genome sequencing is therefore not a text read from start to finish but a list of differences from the reference, each with a measure of how sure the software is.

07 — Reading a genome in fragments
REFERENCE G A T T A C A G C T T A G C C T A G G C A T C A READS T C T C T C G error: seen once 7× 0 COVERAGE coverage 30× across a whole genome: an average of 30 reads over each base variant: in about half the reads at this position schematic
DNAReadoutFocal detail
Plate 07 — No instrument reads a chromosome end to end. The genome is shattered, each fragment is read, and the reads are stacked against a reference. A true variant recurs in many reads at the same position; a random error usually appears in only one read.
A sequenced genome arrives as a list of differences

It is tempting to picture a sequenced genome as three billion letters read in order. What a laboratory actually delivers is a set of variant calls relative to a reference, each with a quality, plus regions where no call could be made because coverage was too thin or the reads could not be placed. Two laboratories using different references, software or thresholds can report different variant lists from the same DNA, so the list can be interpreted only alongside those choices.

The reference has blind spots

A reference genome is a coordinate system, and its gaps become blind spots. The reference used through most of the last two decades was missing about 8 % of the genome, mostly long repetitive regions that short reads could not assemble. In 2022 Nurk and colleagues of the Telomere-to-Telomere consortium published the first gapless human sequence, 3.055 billion base pairs long, which added roughly 200 million bases and nearly 2,000 predicted genes. The consortium assembled it from long reads of a single cell line rather than a person's cells, and its authors included staff of one maker of long-read instruments. The Y chromosome, which that sequence did not include, followed in 2023, when Rhie and colleagues of the consortium assembled it from a different person's DNA. In its statement of competing interests, the 2023 paper names one author as an employee of another maker of long-read instruments, and other authors as having received research support or travel funding from instrument makers.

A single reference also comes from very few people, so reads carrying DNA that the reference lacks either fail to align or align to the wrong place. The Human Pangenome Reference Consortium is building a reference from many people instead. In 2023 Liao and colleagues of the consortium published a first draft built from 47 individuals, and in May 2025 the consortium announced a second data release covering 232.

India has a project of its own. The Department of Biotechnology of the Government of India funded the GenomeIndia project. In January 2025 the government launched the project's data set and archived it in the Indian Biological Data Centre, India's national repository for biological data, through which researchers apply for access. In April 2025 Bhattacharyya and colleagues of the GenomeIndia Consortium described the data set in Nature Genetics as the whole genomes of 10,000 healthy, unrelated people from 83 Indian population groups. Their paper gives underrepresentation as the reason for the work, describing India as one of the highly underrepresented populations in global genomics.

Variant size decides what short reads can see

Variants come in sizes spanning more than eight orders of magnitude. A single-nucleotide variant changes one base, and small insertions and deletions change up to about 50. Structural variants, meaning deletions, duplications, inversions and insertions of more than 50 bases, can span thousands to millions of bases. Copy-number changes, and gains or losses of whole chromosomes, are larger still. A copy-number change alters how many copies of a long stretch of DNA a genome carries.

Short reads handle the smallest and the largest variants well. A single-base change sits comfortably inside a 150-base read, and a whole extra chromosome shows up as a proportional rise in coverage. The middle is hard. A structural variant several thousand bases long cannot be seen inside any one short read, so software has to infer it from indirect clues such as reads that align oddly or a change in coverage, and in repetitive regions the clues are often missing. Much of the reason long-read sequencing exists is to read across that middle range directly.

08 — Variant size against read length
VARIANTS 1 bp SNV 1–50 bp small indel deletion, duplication, inversion, insertion structural variants · 50 bp – 1 Mb >1 Mb to whole chromosome aneuploidy large copy-number change / 1 bp 10 bp 100 bp 1 kb 10 kb 100 kb 1 Mb 10 Mb READS short read · 100–300 bp long read (HiFi) · 15–20 kb typical maker's figure ultra-long nanopore reads >100 kb maker's record: millions of bases longer than a short read: detected indirectly, often missed
DNAReadoutFocal detail
Plate 08 — A variant is easiest to see when a single read spans it. Structural variants — thousands of bases long — sit beyond the reach of short reads, which is much of the reason long-read sequencing exists.

Genome, exome or panel

Not every question needs the whole genome. Less than 1.5 % of the genome encodes protein (Chapter 1). Sequencing just those regions, the exome, costs less and concentrates the reads where most known disease-causing variants sit. Targeted panels go further. A panel is a chosen set of tens to hundreds of genes read at very high coverage, often 500× to more than 1,000×, and that coverage is what lets a tumor panel find a mutation present in only a few percent of the cells in a biopsy. The trade is the usual one in omics, breadth against depth: a panel sees deeply into what it was designed for and nothing else, while a genome sees everything, less deeply.

In practice

In a sequencing request or specification, state at minimum the question, the variant classes that matter, and whether a genome, an exome or a panel is to be read. State the coverage as a minimum across target regions rather than an average, give the read length and the reference build, and set acceptance criteria for quality, such as the fraction of bases at Q30 or above, the duplicate rate and the mapping rate. A result delivered without those parameters cannot be compared with any other result, including a repeat of itself.

+ What this chapter established
  • Genomes are read by breaking DNA into fragments, reading each one, and aligning the reads to a reference or assembling them from their overlaps.
  • Every position is read many times, because coverage is what overcomes both random errors and the uneven sampling of fragments.
  • A true variant recurs across independent reads at one position, while a random error usually appears in a single read.
  • Structural variants several thousand bases long cannot be seen inside any one short read, and reading across them is much of the reason long reads exist.