+ Part VII · From signature to decision

From discovery to routine use.

In 2010 a set of cancer trials at Duke University was halted. The trials had used gene-expression signatures to assign patients to chemotherapy, and independent statisticians could not reproduce the results on which the signatures rested. Part VII asks what separates a signature like those from the omics tests that already inform decisions. Chapter 21 maps where omics decides today, from prenatal screening and cancer treatment to rare disease, prescribing and manufacturing, and Chapter 22 sets out the evidence a signature needs, from locked validation to proof that acting on it helps patients, before it becomes a test someone can act on.

21 — Omics in use today

Where omics already decides.

+ The questionWhere is omics already changing decisions, not just papers?

A working definition of "in use"

In September 2026 investigators reported that their randomized trial in England of a blood test for many cancers had missed its primary endpoint (Chapter 22). As of October 2026 the test is still awaiting a decision by the FDA, and it remains a candidate for use.

A technology is in use when a validated test built on it informs a decision routinely, is paid for, and appears in clinical guidelines or manufacturing specifications. By that definition, omics is further along than its reputation suggests in a few areas and further behind in most. The routine uses are also narrower than the word implies: none of them reports on a whole layer. Each reports a validated subset of one, chosen because it answers a specific question, even where a whole genome is sequenced, as in the rare-disease diagnosis this chapter describes.

44 — Where omics already decides
GENOME EPIGENOME (methylation) TRANSCRIPTOME PROTEOME METABOLOME METAGENOME Prenatal aneuploidy screening Cancer therapy selection Blood-based cancer screening Rare-disease diagnosis Newborn screening Infection diagnosis Drug–gene prescribing (pharmacogenomics) Biopharma process control Population cohorts routine since the late 1990s — omics before the word in routine clinical or industrial use available or at scale, not yet routine in validation, pilot or research blank: not a main route
DNARNAProteinMetaboliteModificationFocal detail
Plate 44 — Omics is already inside routine decisions — prenatal screening, therapy selection, newborn screening — and the genome dominates. The hollow markers are where the next decade's evidence will be decided.
Routine omics is narrow omics

The map is easy to read as evidence that clinical tests now report on whole layers, and they do not. Each routine test has its analysis locked and its performance established in the population it serves. Broad discovery measurements remain research tools, and Chapter 22 describes what it takes to cross from one to the other.

Screening from a blood sample

One of the most widespread clinical uses of genome sequencing is also one of the oldest: counting cell-free DNA fragments in maternal blood to screen for fetal chromosome abnormalities, a kind of test first launched in 2011. It rests on the counting property of short-read sequencing described in Chapter 5 and on the fragment biology of Chapter 14. In a practice bulletin of 2020, the American College of Obstetricians and Gynecologists recommended that prenatal screening be offered to all pregnant patients regardless of age or risk, and it named cell-free DNA as the most sensitive and specific screen for the common abnormalities of chromosome number. The Society for Maternal-Fetal Medicine wrote that bulletin with the college, and in 2025 it issued guidance of its own, which the college endorses as of October 2026. That guidance recommends that cell-free DNA screening for an extra copy of chromosome 21, 18 or 13 be made routinely available to all pregnant patients, and it again names cell-free DNA as the most sensitive and specific screen for those common abnormalities.

Screening for cancer from a blood sample is newer. As of October 2026 the FDA has approved three blood tests for colorectal cancer screening. The first, approved on 12 April 2016, detects methylated DNA of the Septin 9 gene in plasma, and it is approved for adults aged 50 and older at average risk who have been offered the recommended screening tests and have declined them. The FDA approved the second in July 2024, and on 24 July 2026 it approved the third, which looks for molecular signals of colorectal cancer in cell-free DNA from plasma. Both recent tests are approved for adults aged 45 and older at average risk, and the FDA's record for the 2026 test states that a positive result should be followed by colonoscopy. Chapter 22 gives the performance figures of the 2024 test and explains why screening healthy people raises the bar for evidence, and Chapter 25 describes how such tests are approved.

Choosing and following cancer treatment

Cancer treatment is where omics has become most embedded, in three forms. Tumor genome profiling reads tens to hundreds of genes in a biopsy to find mutations that match a targeted drug. In 2017 the FDA approved a broad profiling test covering 324 genes as a companion diagnostic, a test essential for the safe and effective use of a particular drug. Two blood-based profiling tests followed in 2020, and in 2024 the FDA approved a distributable kit covering 517 genes, with claims across tumor types.

Expression signatures measure a panel, a fixed set of genes, in a tumor to estimate the risk that the cancer will return. In 2007 the FDA granted a De Novo request for a 70-gene signature, the first multigene test of its kind. The FDA uses a different verb for each of its main routes: it approves a test of the highest risk class, grants a De Novo request for a novel test of low or moderate risk, and clears a test shown to be equivalent to one already on the market (Chapter 25).

Two large trials then changed practice. The first, TAILORx, was a randomized trial run by the ECOG-ACRIN cancer research group with funding from the US National Cancer Institute. It enrolled 10,273 women with early breast cancer that was hormone-receptor-positive and HER2-negative and had not spread to the lymph nodes. Of the women enrolled, 6,711 with intermediate scores on a 21-gene assay were assigned at random to endocrine therapy alone or with chemotherapy. In 2018 Sparano and colleagues reported that endocrine therapy alone was not inferior to adding chemotherapy, although women aged 50 or younger with scores of 16 to 25 saw some benefit from chemotherapy.

The second, MINDACT, was a randomized trial that enrolled 6,693 women with early breast cancer and used the 70-gene signature to assess genomic risk. In 2016 Cardoso and colleagues reported that many women at high clinical risk but low genomic risk could forgo chemotherapy, judged by survival without distant metastasis at five years. Two of the authors were then at Agendia, the company that makes the 70-gene signature.

The third form is methylation. In brain tumors the methylation of a single gene, MGMT, is routinely tested because it predicts response to a standard chemotherapy (Chapter 6).

In November 2025 the FDA proposed moving nucleic-acid-based companion diagnostics for cancer drugs from its highest risk class to a lower one, governed by special controls, which are requirements written for that kind of test. This guide reads the proposal as a sign that the category has matured, and as of October 2026 it is still a proposal. A parallel order did become final: it covers companion diagnostics based on in situ hybridization, which marks a gene in a tissue section with a probe that pairs to it, and the order took effect in September 2026 (Chapter 25).

On 15 May 2026 the FDA approved a companion diagnostic that tests for molecular residual disease, the traces of cancer that remain after treatment and can be detected only by molecular tests. The test is designed from each patient's own tumor and detects circulating tumor DNA in plasma (Chapter 14). It is intended to identify patients with muscle-invasive bladder cancer who may benefit from treatment with the drug atezolizumab. Four days later the FDA approved a blood-based panel with a much larger footprint than the 2020 tests, covering small variants in 741 genes.

Payment, the second condition of the definition at the start of this chapter, is settled differently in each jurisdiction. As of October 2026, Medicare covers sequencing-based tests for patients whose cancer is recurrent, relapsed, refractory, metastatic or advanced at stage III or IV, under a national coverage determination first effective in March 2018. Among other conditions of that national coverage, the test must be an FDA-approved or cleared companion diagnostic for the patient's cancer and must be run in a CLIA-certified laboratory (Chapter 25). The same determination allows Medicare's regional contractors to cover a sequencing test for such a patient when the FDA has not approved or cleared it. The Medicare contractor Palmetto GBA designed and runs MolDX, a program that sets the coverage, coding and pricing of molecular diagnostic tests for several of Medicare's regional contractors. Palmetto GBA's 2019 manual for the program states that CMS, the federal agency that runs Medicare, has directed MolDX to follow the ACCE criteria that Chapter 22 describes. As of October 2026, Medicare pays for most laboratory tests at the rates of its Clinical Laboratory Fee Schedule.

In the European Union, payment for a test can depend on a health technology assessment, an evaluation of a medicine, device or test that informs a health system's decisions on paying for it. A market-access consultancy states that companion diagnostics are often the subject of such assessments because of their high cost and novelty. Regulation (EU) 2021/2282 on health technology assessment has applied since January 2025. It provides for joint clinical assessments, allows tests of the highest risk class to be selected for them and leaves pricing and reimbursement to each member state. In India, a member of Parliament stated that the public insurance schemes, Ayushman Bharat among them, cover only the inpatient costs of cancer treatment and leave diagnostic tests to be paid for out of pocket.

Rare disease, from diagnosis to newborn screening

For children with suspected genetic disease, sequencing has become the first test rather than the last, and some of the evidence for that comes from studies that also included adults. Meta-analysis, the pooling of results across studies, puts the diagnostic yield of genome sequencing at 34 % to 41 %, compared with about 10 % for the chromosomal microarrays it replaces. In 2018 Clark and colleagues pooled 37 studies of 20,068 children in one such meta-analysis and found a yield of 41 % for genome sequencing. Their estimate rests on 374 of those children, in seven studies, and the paper's senior author was then at an institute that offers rapid genome sequencing. In 2023 Chung and colleagues pooled 161 studies of 50,417 children and adults with rare disease and found a yield of 34 % for genome sequencing, with a 95 % confidence interval of 30 % to 38 %.

Solved example: what the first genetic test finds in 1,000 children

Clark and colleagues found a diagnosis in 41 % of the children tested by genome sequencing and in 10 % of those tested by chromosomal microarray. Suppose that both pooled yields apply to the same 1,000 children with a suspected genetic disease. A microarray as the first test then finds a diagnosis for 10 % of 1,000, or about 100 children, and leaves about 900 without one. Genome sequencing as the first test finds 41 % of 1,000, or about 410, which is about four times as many. Sequencing first therefore gives a diagnosis to about 310 more children than a microarray first, and if sequencing found a diagnosis in only 30 % of the children, the lower bound of the 95 % confidence interval in the 2023 meta-analysis, it would still give about 200 more.

45 — What the first genetic test finds
CHROMOSOMAL MICROARRAY 10 in 100 diagnosed GENOME SEQUENCING 41 in 100 diagnosed 31 more children in 100 diagnosed by the first test pooled yields from one meta-analysis: 37 studies, 20,068 children; the genome figure rests on 374 children in 7 studies; both yields applied to the same children, as in the chapter's solved example; the senior author was then at an institute that offers rapid genome sequencing
ReadoutFocal detail
Plate 45 — Applied to the same 100 children, the pooled yields of a 2018 meta-analysis give 10 diagnoses from a chromosomal microarray and 41 from genome sequencing: the choice of first test decides how many families get an answer from it.

In a pilot published in 2021, the investigators of England's 100,000 Genomes Project sequenced the genomes of 4,660 children and adults from 2,183 families with undiagnosed rare disease. They reported a genetic diagnosis for 25 % of the probands, the affected family members through whom the families entered the study, and about a quarter of the diagnoses had immediate consequences for care. In intensive care, rapid genome or exome sequencing typically returns results within a few days, and in record cases within hours. In a 2024 review, Kingsmore and colleagues pooled 44 studies of critically ill children with diseases of unknown cause, and they reported a genetic diagnosis in about 37 % of the children and a change in management for about a quarter. Kingsmore was also the senior author of the 2018 meta-analysis, and when the review was published he and his co-authors were at the same institute, which offers rapid sequencing.

Newborn screening by tandem mass spectrometry, a targeted metabolomics test on a dried blood spot, has been routine since the late 1990s and screens every baby in many countries for dozens of inherited metabolic conditions. Genome sequencing at birth is now being tested at scale. Genomics England runs the Generation Study with the NHS and aims to screen the genomes of up to 100,000 newborns for over 200 rare genetic conditions that can be treated in early childhood. It reported in October 2025 that 25,000 babies had enrolled. In 2024 the GUARDIAN study in New York reported results from its first 4,000 newborns. Columbia University Irving Medical Center and NewYork-Presbyterian ran the study with funding from the drug maker Sanofi, the sequencer maker Illumina, the genetic testing company GeneDx and the Columbia Precision Medicine Initiative.

Infection, drugs and manufacturing

Unbiased metagenomic sequencing is used for hard-to-diagnose infections, as Chapter 13 described, and pathogen genome sequencing has become a routine tool for tracking outbreaks and antimicrobial resistance. Pharmacogenomics uses a person's genotype to choose a drug or its dose. The Clinical Pharmacogenetics Implementation Consortium maintains guidelines for gene–drug pairs. The FDA also keeps a table of pharmacogenomic biomarkers in drug labeling, the official prescribing information that comes with each drug, and the table runs to several hundred entries.

In biopharmaceutical manufacturing, omics methods serve as quality-control instruments. Mass spectrometry characterizes therapeutic proteins and identifies residual host-cell proteins individually. It also monitors glycosylation, the sugar chains attached to a protein, as a critical quality attribute, which is a property that should stay within set limits to ensure the drug's quality (Chapter 10). Sequencing confirms the identity and stability of the cell lines that make the drug.

Population cohorts: the research base for the next decade

Large cohorts that pair omics with health records are where most future clinical uses are being discovered. In 2025 the UK Biobank Whole-Genome Sequencing Consortium reported whole-genome sequences for 490,640 of the biobank's participants. The US All of Us Research Program's August 2026 data release includes more than 535,000 short-read genomes and over 14,000 long-read genomes, with proteomics and RNA sequencing on thousands of samples. GenomeIndia's 10,000 genomes give Indian research its own reference (Chapter 4). UK Biobank is also measuring proteins in 600,000 samples, with the full data due in 2027, and the expansion will link genetic risk to circulating proteins at a scale not seen before (Chapter 9).

In practice

Place any product or project on the map before planning it. Which layer does it measure, for which decision, in which population, and is that combination already routine, in validation, or still research? The answer sets the evidence needed, the competitors and precedents to study, and the likely regulatory route. A new test in a filled-in cell of the map has a precedent to follow; one in an empty cell will have to build its own case.

+ What this chapter established
  • Routine omics tests report narrow, validated subsets of one layer, each answering one question, even when they sequence a whole genome.
  • The genome dominates: prenatal screening, tumor profiling, rare-disease diagnosis and pharmacogenomics.
  • Targeted metabolomics has screened newborns since the late 1990s, and newborn genome screening is being piloted at scale.
  • Population cohorts that pair omics with health records are the discovery base for the next decade.