07 — Transcriptomics

Counting what the cell is reading.

+ The questionKnowing a gene is present, how do we know the cell is using it, and how much?

A measurement that is really a count

A messenger RNA molecule is transcribed from one gene's sequence when the cell uses that gene, and it ends in a tail of A bases. The more intensely the cell uses a gene, the more copies of its messenger RNA it holds at any moment, and biologists call that level of use the gene's expression. Measuring gene activity therefore means measuring how many copies of each RNA are present, a steady-state level that reflects both how fast each RNA is made and how fast it is degraded. A typical mammalian cell holds on the order of a few hundred thousand messenger RNA molecules, spread across roughly ten thousand genes that are active in that cell type, with some genes represented by thousands of copies and others by one or two.

RNA sequencing, or RNA-seq, measures those levels by counting. A laboratory extracts RNA from a sample, and most of it is ribosomal RNA, the structural RNA of the protein-making machinery, which carries no information about gene activity. The laboratory therefore removes the ribosomal RNA, or it captures the messenger RNA selectively by the string of A bases on its tail. Reverse transcriptase, an enzyme that copies RNA into DNA, turns the remaining RNA into complementary DNA, or cDNA, which is fragmented, fitted with adapters and sequenced exactly as a genome library would be (Chapter 4). Software then aligns the reads to the genome or to a catalog of known transcripts and tallies the number of reads landing on each gene.

13 — From tissue to a count table
tissue RNA AAAA AAAA AAAA cDNA reverse transcription: RNA copied into DNA so it can be amplified and sequenced fragments + reads map to genes exon intron one read is split across an exon junction count table S1 S2 S3 GENE A 1240 1310 1185 B 12 8 15 C 530 610 488 D 0 3 1 E 88 42 97 reads per gene rise with the gene's RNA level, its length and the sample's depth schematic illustrative counts
DNARNAReadoutFocal detail
Plate 13 — RNA cannot be sequenced directly on most machines, so it is copied into DNA first. What comes out is not a measurement of any one molecule but a count: how many reads landed on each gene, which rises with the gene's steady-state RNA level and with its length.

The result is a count table: genes down one side, samples across the top, and in each cell of the table the number of reads. That number counts sequenced fragments, not molecules. The fragment count is proportional to the number of molecules of the transcript, multiplied by the transcript's length and by how efficiently the transcript survived capture and copying. All the transcripts in a sample also compete for the same fixed number of reads, so that total is divided among them and each count is a share of it.

Why raw counts mislead

Two of those factors distort comparisons unless they are corrected. The first is sequencing depth, the total number of reads a sample receives. Genome laboratories use the word depth for the coverage of each position (Chapter 4), but in RNA-seq the word means the number of reads in a whole sample. If one sample receives 40 million reads and another 20 million, every gene in the first will have roughly twice the count for reasons unrelated to biology. The second is transcript length. A longer transcript is cut into more fragments, so at the same number of molecules it collects more reads.

14 — Raw counts and counts per kilobase
ONE SAMPLE · LENGTHS TO SCALE GENE A · 1,000 bases GENE B · 4,000 bases one tick = 100 reads RAW READS 0 250 500 750 1,000 500 A 1,000 B B looks twice as active ÷ length in kilobases READS PER KILOBASE 0 250 500 750 1,000 500 A 250 B per kilobase, A is twice B schematic · numbers from the solved example
DNARNAReadoutFocal detail
Plate 14 — A longer transcript is cut into more fragments, so at the same number of molecules it collects more reads. Dividing each count by the transcript's length reverses the order of these two genes: per kilobase, A has twice B's reads.
Solved example: correcting two genes for length

In one sample, gene A is 1,000 bases long and has 500 reads, while gene B is 4,000 bases long and has 1,000 reads, so on raw counts B looks twice as active. Dividing each count by the gene's length in thousands of bases, or kilobases, gives 500 divided by 1 for A, which is 500 reads per kilobase, and 1,000 divided by 4 for B, which is 250 reads per kilobase. Per molecule, A is therefore present at twice B's level, the reverse of what the raw counts suggested. Scaling each sample's length-adjusted values so that they sum to one million gives transcripts per million, or TPM, which can be compared between samples of different depth. For comparisons of the same gene across samples, statistical packages use related methods that also guard against a few very highly expressed genes absorbing a large share of the reads.

The third factor, composition, is subtler. Because the total number of reads is fixed, a sample in which one gene becomes enormously abundant leaves fewer reads for everything else, and every other gene then appears to fall although nothing changed for it. Differential expression is the comparison of each gene's level between conditions, and the normalization methods used for it estimate a scaling factor from the genes that did not change, precisely to avoid that false fall. Chapter 13 meets the same problem in a different guise.

Differential expression ends in a list of the genes whose expression changed, and any share quoted from that list takes the list as its denominator. The 7 % of the opening is a share of this kind. In the statement of March 2018 that the opening quotes, NASA gave it as a share of the gene expression that had changed during spaceflight, so the figure counted a share of the genes whose expression had changed, not a share of the genome.

A higher count can come from length or depth alone

A higher count for one gene than another says little on its own, because the longer gene collects more reads and a deeper sample collects more of everything. Counts become comparable only after normalization, and even then the comparison that holds up best is the same gene across samples under the same protocol, not different genes within one sample.

How many reads is enough

Depth decides which genes can be measured at all. A replicate is one of several independent samples of the same condition. The ENCODE consortium's data standard for bulk RNA-seq asks for about 30 million aligned reads per replicate. The consortium last updated the standard in June 2017, and as of October 2026 that version is still current. At 30 million reads abundant transcripts are counted precisely and rare ones are sampled sparsely: a gene that yields 5 reads in one sample and 10 in another has not necessarily doubled, because counts that small fluctuate by chance by about the square root of their value. Detecting modest changes in genes with few RNA copies needs more reads, more biological replicates or both. Replicates matter more than depth in most designs, because the variation between individuals or cultures is usually larger than the counting noise.

One gene, many transcripts

Most human genes can be spliced in more than one way. A gene's exons are the segments of it that are kept in a messenger RNA, and the cell can join different subsets of them into different messenger RNAs, which may encode different proteins. Short reads see only fragments of each transcript, so software has to infer the relative amounts of each version statistically from the reads that happen to span a particular junction. Long-read sequencing can read a whole transcript in one pass, from start to tail. In 2023 Al'Khafaji and colleagues at the Broad Institute published a library method that joins several cDNA molecules end to end before long-read sequencing. On the long-read sequencer they used, the method raised the output more than 15-fold, to nearly 40 million cDNA reads per run. The authors disclosed a licensed patent application on the method, and after the paper was submitted the Broad Institute entered a collaboration agreement on the research with the sequencer's maker.

Before sequencing: arrays and targeted assays

Before RNA-seq, laboratories measured gene expression with microarrays: glass slides carrying thousands of fixed DNA probes, each designed to pair with one gene's RNA. Labeled cDNA from the sample pairs with its probes, and the brightness of each spot shows how much of that RNA was present. Arrays exploit pairing, just as sequencing does, but they read intensity rather than counting, and intensity has a floor set by background and a ceiling set by saturation. Arrays also measure only what their probes were designed for. RNA-seq counts fragments instead of reading an intensity, and counting extends the range. RNA-seq also reads sequence, which finds transcripts nobody knew to look for.

Targeted assays remain important, especially in the clinic. Quantitative PCR measures a handful of chosen RNAs with high precision, and several established multigene tests that guide cancer treatment decisions are built on it. The general pattern recurs across omics: discovery uses the broad method, and a decision that will be made repeatedly uses a narrow, validated one.

What RNA can and cannot show

A transcriptome is a snapshot of the last few hours of the cell's decisions, averaged over every cell in the sample, and both limits matter. A tissue is a mixture, so a change in the bulk signal can mean that every cell changed or that the mixture of cell types changed, and Chapter 12 describes how single-cell methods separate the two. RNA is also not protein: the relationship between the two is imperfect, for reasons Chapter 15 sets out.

In practice

Put RNA quality and design into the specification before the first sample is collected. Set a minimum RNA integrity value, a score of how intact the RNA is, as an acceptance criterion, because degraded RNA biases counts toward the ends of transcripts. Plan at least three biological replicates per condition, and more when the effect sought is small. Balance conditions across processing batches, the groups of samples prepared or run together, a point Chapter 18 returns to. If the result will drive a repeated decision, plan a targeted confirmation assay from the start.

+ What this chapter established
  • RNA-seq measures gene activity by counting the sequenced fragments that land on each gene.
  • Counts must be normalized for sequencing depth, transcript length and composition before they can be compared.
  • Replicates and depth together decide which changes can be detected.
  • A transcriptome is an average over cells and hours, and it does not stand in for the proteome.