What cells leave behind.
+ The questionWhat can the vesicles and DNA fragments that cells shed into the blood tell us about tissue we cannot biopsy?
A tube of blood as a sample of the whole body
A tube of blood drawn from the arm holds DNA from the bone marrow, the liver and the walls of blood vessels, and in pregnancy from the placenta. When a cell dies, enzymes cut its DNA into fragments, and some of those fragments reach the bloodstream. Living cells also release membrane-bound packages called extracellular vesicles, or EVs, which carry proteins, RNA and lipids from the cell that made them. Both kinds of material come from almost every tissue, a growing tumor included. A blood draw is therefore a sample, however diluted, of tissues that could otherwise be reached only by a tissue biopsy, and that is the idea behind liquid biopsy.
The same fact sets the difficulty. Material from the tissue of interest is mixed with far more material from everywhere else, and much of it sits at sizes and concentrations near the limits of what instruments can detect.
Cell-free DNA: fragments with a fingerprint
Cell-free DNA in plasma is mostly short fragments of about 166 base pairs, and the length has a physical cause. In the nucleus, DNA is wrapped around spools called nucleosomes, with a short stretch of linker DNA between one spool and the next. When a cell dies, enzymes cut the exposed linkers first, so the pieces released are about one spool long. The body clears these fragments from the blood quickly: their half-life there ranges from 15 minutes to several hours, half-life being the measure that Chapter 1 defines. What sits in a tube therefore reflects recent cell death.
Each fragment carries three kinds of information. Its sequence carries any mutation of the cell that released it. Its methylation, the tissue-specific pattern of Chapter 6, matches that of the tissue that released it, so the methylation of many fragments together shows which tissues they came from. In a 2018 study, Moss and colleagues compared the methylation of cell-free DNA pooled from 105 healthy donors with a reference atlas of cell types, and found most of it came from white blood cells and the precursors of red cells, with about 1 % from liver cells. The third kind of information is the fragment's length and end positions, which differ by origin: fetal fragments are shorter, peaking around 143 base pairs, and fragments from a tumor are shorter than healthy ones too.
The first large success was prenatal. Placental DNA enters the mother's blood early in pregnancy, and between 10 and 14 weeks of pregnancy it typically makes up around a tenth of the cell-free DNA, enough to test reliably. A laboratory sequences millions of fragments and counts how many map to each chromosome, and an extra copy of chromosome 21 shows as a small but measurable rise above the expected count. This non-invasive prenatal screening reached the clinic in October 2011, when Sequenom announced that it had launched a test in its own US laboratory for pregnancies at high risk of Down syndrome.
In a 2020 practice bulletin, the American College of Obstetricians and Gynecologists recommended that prenatal screening be offered to every pregnant patient. In 2025 the Society for Maternal-Fetal Medicine recommended that cell-free DNA screening for an extra copy of chromosome 21, 18 or 13 be made routinely available to all pregnant patients, in guidance that the college endorsed. Both documents name cell-free DNA as the most sensitive and specific screen for the common abnormalities of chromosome number (Chapter 21).
Tumor DNA: a detection problem set by the tube
Circulating tumor DNA, the part of the cell-free DNA that comes from a tumor, is the basis of blood tests that choose cancer treatments, monitor response and, increasingly, screen for cancer. In advanced disease it can be a large share of the cell-free DNA. In early disease it is tiny, often below 1 % of fragments.
A 2014 study by Bettegowda and colleagues at Johns Hopkins showed how far so small a share limits detection. The team first found mutations in each patient's tumor and then looked for the same mutations in plasma, with methods based on digital PCR that can detect a single mutant molecule in the DNA from up to 5 mL of plasma. The study's 640 patients formed three groups, and the largest held 410 patients with 18 kinds of tumor. In that group, circulating tumor DNA was detectable in 82 % of the patients whose cancer was at stage IV and in only 47 % of those at stage I, the earliest stage. The 47 % is the figure that the text of the authors' manuscript gives, and a chart in the same manuscript draws it at about 44 %.
The five senior authors owned stock in Personal Genome Diagnostics, a company two of them had co-founded, and the university held patents related to the work. Other authors gave addresses at Life Technologies, Amgen and other companies. The authors note that the shares they found were the most that the amount of plasma collected could give. The limit is set by how few tumor fragments a tube of blood holds, as the example below shows. It is not set by the instrument's analytical sensitivity, its ability to detect a weak signal. Analytical sensitivity is a different quantity from the diagnostic sensitivity of Chapter 13, the share of true cases that a test detects.
How few tumor fragments a tube holds depends on how much cell-free DNA the plasma carries and on the tumor's share of it. In a 2024 study of 862 healthy participants in a cancer screening program in Hong Kong, Malki and colleagues at the Chinese University of Hong Kong measured a median of 7.39 ng of cell-free DNA per mL of plasma. Individual values ranged from 1.61 to 41.01 ng per mL. The paper declared that three of its authors held equity in companies, among them DRA, Take2, Insighta and Illumina, and that several authors were directors of such companies. Two of the three also received patent income from companies that included GRAIL and Illumina, and a patent application had been filed on the study's data.
The Hong Kong study's median is 7.39 ng of cell-free DNA per mL of healthy plasma, and one copy of the haploid genome weighs about 3.3 pg, so each mL holds about 7.39 ng ÷ 3.3 pg, or about 2,240 copies of the genome. A 10 mL blood tube yields about 4 to 5 mL of plasma, which gives roughly 9,000 to 11,000 copies of any one position in the genome. If the mutant allele makes up 0.1 % of the copies at that position, which corresponds to a tumor fraction of roughly 0.2 % for a mutation on one of the two copies, the whole tube holds about 9 to 11 mutant fragments. Extraction and library preparation lose some of them, so only a few may remain, and no sequencer, however accurate, can find fragments that were never in the sample.
The methods that work in early disease therefore pool evidence across many positions instead of relying on one. They track many mutations at once, read methylation patterns across thousands of regions, and profile fragment lengths across the genome. Error correction with molecular identifiers, the UMIs of Chapter 12, separates true rare variants from copying errors. In July 2024 the FDA approved a blood test for colorectal cancer screening that combined mutations, methylation and fragment patterns, and in July 2026 it approved a change that makes the test read methylation alone (Chapter 25). Tests that aim to detect many cancers from one draw are further behind, and Chapter 22 examines why the evidence bar for them is so high.
Extracellular vesicles: packages with a return address
EVs are particles enclosed by a lipid bilayer, released by essentially every cell type, and they range from about 30 nm to a micrometer or more. They carry surface proteins from the membrane of the cell that made them and cargo from its interior, including proteins, RNA fragments and metabolites. In principle each vesicle is a small, protected sample of one cell, and that is why EVs attract so much interest, both as biomarkers and as vehicles for delivering drugs.
The International Society for Extracellular Vesicles asks for careful language in its 2024 guideline, MISEV2023, because the biology is easy to overclaim. It treats "small EVs" as an operational term, often used for particles under 200 nm as measured by a given method. It discourages names that imply where inside the cell a vesicle formed unless that origin has been shown.
MISEV2023 also asks a study to report the purity of its EV preparation, because EVs share their size range with other particles in blood. The study should test for at least one protein that marks material other than vesicles. Materials isolated along with the vesicles are called co-isolates, and for blood the guideline asks how far EVs were enriched over the co-isolates that matter to the study, such as platelets, lipoproteins or soluble proteins. Lipoprotein particles, which carry fats and cholesterol, are among the main co-isolates. MISEV2023 notes that all kinds except high-density lipoprotein overlap EVs in size, and that some kinds outnumber EVs in blood by orders of magnitude. Aggregates of protein, and of protein with RNA, also end up in EV preparations.
Every isolation method trades purity against yield. Ultracentrifugation pellets particles by density and size, and size-exclusion chromatography separates them by size in a column. Precipitation reagents recover a great deal of material and a great deal of contamination with it. Capture with antibodies against surface markers gives high purity for one subpopulation and excludes the rest. The method chosen therefore decides which EVs a study is actually about.
Measuring vesicles: the detection limit decides the answer
A typical EV is smaller than the wavelength of light, scatters very little of it and carries only a limited number of copies of any one surface protein, so measuring EVs is first a problem of detection limits. Many conventional flow cytometers cannot tell a small EV's scatter from background. In 2018 van der Pol and colleagues reported a multicenter study run through a working group of the International Society on Thrombosis and Haemostasis. In that study, 33 laboratories measured the same samples on 46 flow cytometers, and fewer than half of the instruments detected vesicles in a gate of 600 to 1,200 nm in diameter. The study estimated those diameters from bead calibration and a light-scattering model. Two of its authors declared shares in the company that supplied the study's calibration system.
Other methods reach smaller sizes by different routes. Nanoparticle tracking follows the scattered light of each particle as it drifts and sizes it from how fast it moves, down to about 50 nm, and its fluorescence modes count labeled subsets. High-sensitivity flow instruments and single-molecule fluorescence cytometers count particles by their fluorescent labels instead of their scatter, so detection depends on labeling more than on size. Surface-capture chips and super-resolution microscopes image individual captured vesicles. The consequence is that a measured concentration of EVs depends on the sample, the instrument's detection limit and the analysis settings together.
A 2024 bench study shows the point plainly. Kim and colleagues measured portions of one preparation of vesicles from cultured colorectal cancer cells on three instruments: a single-molecule flow cytometer that their University of Washington laboratory had built, and two commercial high-sensitivity flow cytometers, the CellStream from Cytek Biosciences and the CytoFLEX from Beckman Coulter. The authors included researchers at the US National Cancer Institute. Four of the authors declared a financial interest in Pangnostics, which had licensed the single-molecule instrument's technology from the university, and the corresponding author, Daniel Chiu, was one of them.
For vesicles labeled with antibodies to three tetraspanins, surface proteins common on EVs, the single-molecule instrument reported 5.5 × 10⁸ vesicles per mL, the CellStream 2.6 × 10⁷ and the CytoFLEX 7.5 × 10⁶, a spread of about seventy-fold. The vesicles that each counted had median diameters of 57, 83 and 105 nm. Each instrument counted what it could see. From bead calibration, the authors put the smallest vesicle that the CellStream could detect at about 67 nm across and the CytoFLEX's at about 80 nm. They put the single-molecule instrument's limit at 35 nm or less, the size of the smallest vesicle they saw by super-resolution microscopy. They also judged that the beads had set the two commercial limits lower than they really were. When the authors restricted all three data sets to a common range of size and fluorescence, the instruments agreed significantly better, and better still with stricter cutoffs.
A report of 10⁹ particles per mL means little unless it states what the instrument could detect, in calibrated units of size and fluorescence, and which gates were applied. MISEV2023 asks every study that uses single-vesicle flow cytometry to fill in the community's reporting framework for EV flow cytometry, MIFlowCyt-EV, whose categories include assay controls and instrument calibration, and to define the upper and lower limits of detection. The 2024 bench study ran controls that it describes as based on the guidelines of the International Society for Extracellular Vesicles: buffer alone, a detergent that dissolves membranes to show that the counted particles were vesicles, and a dilution series to show that single particles were counted.
Where EV diagnostics stand
EVs carry protected RNA and tissue-specific proteins, which makes them promising candidates as biomarkers. Turning such candidates into validated tests has been slow, largely because of the measurement problems above. One EV-based test for prostate cancer reads RNA from vesicles in a urine sample. In 2019 the company that then made it announced that the FDA had granted the test Breakthrough Device designation (Chapter 25). The company also stated that the test had been added to a clinical guideline. A search of published sources for this guide in October 2026 found no EV-based diagnostic with FDA clearance or approval. Most EV measurement remains a research activity, and the work that will move it forward is largely metrological: calibrated instruments, stated detection limits, reference materials and agreed controls.
So far, the tools for showing that an EV method measures what it claims are mostly reporting rules. MISEV2023 lists the minimal information that a study of EVs should report. In 2020 a working group of vesicle, cytometry and thrombosis researchers published MIFlowCyt-EV, which sets out what an EV flow-cytometry study should report but does not prescribe specific protocols. In 2017 Van Deun and colleagues described EV-TRACK, a knowledgebase that gathers published EV experiments and scores how transparently each one was reported.
As of October 2026 the field still lacks a certified reference material for vesicles, a material whose properties have known values stated on a certificate, so that a method's results can be checked against those values. Chapter 17 places reference materials in the chain of a test and sets out what has been proposed for vesicles, and Chapter 19 describes how a method is shown to work.
For EV work, state with every concentration the instrument, its detection limit in calibrated units, the size and fluorescence gates, and the isolation method. Run buffer-only, detergent-lysis and dilution-series controls. Screen antibodies and fluorophores against the particle population on the instrument that will be used, because dye brightness and antibody labeling efficiency decide what a fluorescence-based counter can detect. When comparing with published values, compare within the same size and fluorescence window or not at all.
- Cell-free DNA and EVs carry information from tissues that cannot easily be biopsied.
- Cell-free DNA fragments reveal mutations and, through methylation, their tissue of origin, and fragments from a fetus or a tumor are shorter than the rest.
- In early cancer, the number of tumor fragments in the tube limits detection, however accurate the sequencer.
- EV counts depend on the instrument's detection limit, so without calibration and stated limits they cannot be compared.
Let's Talk