+ Part III · Beyond nucleic acids
Measuring what cannot be copied.
Glucose, galactose and fructose are built from the same atoms and have the same exact mass, 180.0634 daltons, so a mass spectrometer can weigh any of the three sugars to within about a thousandth of a dalton and still not say which one it has weighed. Proteins and metabolites are where the cell's decisions become action, and neither can be copied or read by pairing, the two properties that make nucleic acids easy to measure (Chapter 2). This part follows the two routes around that limit, weighing molecules and binding them, and ends with the small molecules, where saying which molecule is present is harder than detecting that something is there.
Weighing the workforce.
+ The questionIf proteins cannot be copied or paired, how does a mass spectrometer identify thousands of them in one run?
The layer that acts
The human genome has about 20,000 genes that encode proteins, yet the proteome is larger and more varied than that count suggests. The same gene can give rise to several different protein molecules, because RNA can be spliced in different ways and because finished proteins are cut, folded and decorated with chemical groups such as phosphates and sugars. Each distinct molecular form is called a proteoform. Proteins do most of the work that makes a cell what it is: they catalyze its chemistry, carry its signals, build its structure and defend it. Many of the differences that matter for that work, such as whether an enzyme has been switched on by a phosphate, exist only at this layer.
Proteomics has made steady progress on coverage. Each year the Human Proteome Project, an initiative of the international Human Proteome Organization, reviews the public mass-spectrometry and antibody evidence that each predicted human protein exists. In the project's 2025 report, Deutsch and colleagues found credible protein-level evidence for 93.6 % of the 19,435 proteins predicted from the genome. The open question is therefore no longer whether a protein can be detected somewhere, but how many proteins can be measured in one sample, how precisely and how cheaply.
Weighing peptides instead of proteins
A mass spectrometer measures the ratio of a molecule's mass to its electric charge, the m/z of Chapter 3, so the molecule first has to become a charged particle in a vacuum. For proteins and peptides this is almost always done by electrospray. The liquid emerging from a chromatography column is sprayed from a fine needle held at high voltage, the charged droplets shrink as the solvent evaporates, and the dissolved molecules are left carrying one or more extra protons.
Electric or magnetic fields then sort the ions, and different instruments do it differently. A quadrupole passes only ions of a selected m/z through an oscillating field, so it works like a tunable filter. A time-of-flight analyzer gives every ion the same push and times its arrival, because lighter ions fly faster. An orbital trap lets ions circle a central electrode and measures how fast they oscillate, which depends on their m/z. One maker specifies the mass accuracy of its high-resolution instrument as better than 3 parts per million (Chapter 3). A few parts per million is enough to distinguish molecules whose masses differ in the third decimal place.
Most proteomics is done bottom-up: the proteins are first digested with trypsin into short chains of amino acids called peptides. Trypsin is an enzyme that cuts after the amino acids lysine and arginine, written K and R in the one-letter code. Peptides suit the instrument better than whole proteins do. Whole proteins are large, carry many charges and break unpredictably, whereas peptides of roughly 7 to 30 amino acids ionize well, separate well by chromatography and break in predictable places, so their sequences can be read from their fragments.
Liquid chromatography separates the peptides over a gradient lasting tens of minutes to hours, so that at any moment only a fraction of them enter the instrument. For each slice of time the instrument records a first spectrum, MS1, of all the peptide ions present. It then selects ions, breaks them by collision with gas and records the masses of the fragments in a second spectrum, MS2, and a single run records tens of thousands of MS2 spectra.
Reading a peptide from its fragments
A peptide breaks mostly along its backbone, between one amino acid and the next. Each break produces two pieces, one containing the start of the peptide and one containing the end, and across the many copies of a peptide in the instrument the breaks occur at every position. The pieces containing the end, called y ions, form a ladder: y1 is the last amino acid, y2 the last two, and so on. The difference in mass between consecutive rungs is the mass of one amino acid, so the gaps, read in order, give the sequence from its end.
The tryptic peptide LVNELTEFAK comes from bovine serum albumin, a protein widely used as an instrument standard, and it appears in MS1 carrying two charges at m/z 582.32. In its MS2 spectrum the y ions fall at 147.11 for y1, 218.15 for y2 and 365.22 for y3. The gap from y1 to y2 is 218.15 minus 147.11, or 71.04, which is the mass of alanine, A. The gap from y2 to y3 is 365.22 minus 218.15, or 147.07, the mass of phenylalanine, F. Further up the ladder the gaps are 129.04, 101.05, 113.08, 129.04, 114.04 and 99.07, which read E, T, L, E, N and V, so the ladder gives the sequence from the end backwards. One limit is built in: leucine and isoleucine have the same mass, 113.08, so this ladder cannot tell them apart without additional evidence.
From spectra to a protein list
In practice laboratories do not read the ladder by eye. Search software takes every protein sequence in a database, cuts it into peptides by computation, predicts the fragment spectrum of every resulting peptide and scores each observed spectrum against the candidates. It reports the best-scoring match if that score clears a threshold, and the threshold is set statistically. The software searches the real database and also a decoy database of reversed or scrambled sequences that cannot be present in the sample, so the number of decoy matches above a score estimates how many of the real matches above it are false. Laboratories typically report results at a 1 % false discovery rate, the expected share of false matches among those accepted, for peptides and again for proteins.
A further step, protein inference, turns peptides into proteins, and it is the least certain step in the chain. Many peptides are shared between related proteins or between proteoforms of one gene, so the peptides found often leave open which member of a family was present. That ambiguity is why results list protein groups, each the set of proteins that the same peptides could have come from, rather than single proteins.
A proteomics result lists protein groups inferred from peptide matches above a statistical threshold. A protein missing from the list was not detected in that run, but it was not necessarily absent. Shared peptides make some identities ambiguous, and a protein identified from a single peptide deserves less confidence than one supported by many.
Choosing what to fragment
The instrument cannot fragment every ion at once, so it has to choose. In data-dependent acquisition it selects the most intense ions in each MS1 scan, and that choice is partly random, so a peptide measured in one run may be skipped in the next, which leaves gaps in the data. In data-independent acquisition it fragments everything within successive m/z windows and relies on software to untangle the mixed fragment spectra, so the result is more complete and more reproducible across samples.
A 2024 method study shows what narrow windows on a current instrument can reach. Guzman and colleagues at the University of Copenhagen ran narrow-window data-independent acquisition on one instrument model and measured about 10,000 human protein groups from a digest of one human cell line in a 30-minute run. Fourteen of the study's 22 authors were staff of the company that makes the instrument.
Plasma is harder, for the dynamic-range reason Chapter 2 set out: albumin and a few dozen other abundant proteins can take almost all of the instrument's capacity. Laboratories therefore remove the most abundant proteins before measurement, or enrich lower-abundance proteins on the surfaces of nanoparticles. Developers of the newest enrichment workflows report several thousand proteins.
The size of the gain from enrichment shows in a 2025 comparison of six plasma workflows by Beimers and colleagues at the University of Wisconsin–Madison, who ran each workflow five times on one commercial plasma sample. Plasma measured directly, with no depletion or enrichment, gave about 600 proteins per run, and plasma enriched on the nanoparticles of one company, Seer, gave about 4,500. A trade report of the study states that Seer initiated the comparison and paid for some of its assays and for the plasma, and that at the time the senior author sat on Seer's scientific advisory board and consulted for Thermo Fisher Scientific. Völlmy and colleagues at Roche compared common plasma workflows in a study the company funded, and in 2026 they reported that enrichment identified up to 4,600 proteins. The next chapter describes the other route to the faint end.
How much, and in what form
Mass spectrometry measures ion signal, and different peptides ionize with different efficiency, so signal is not directly a quantity. Relative quantity compares the same peptide across samples, and it comes from signal intensity or from labeling each sample with an isotope tag and measuring the samples together. Some tags differ in mass and are told apart in the first spectrum, whereas isobaric tags weigh the same and are told apart by reporter ions released on fragmentation. Absolute quantity requires an internal standard, a known amount of an isotope-labeled copy of the peptide added to the sample. Clinical mass spectrometry assays are built this way, and each one is narrow, targeted and calibrated.
Modifications can be studied directly, because a phosphate or a sugar adds a known mass to the peptide that carries it. Phosphoproteomics enriches phosphorylated peptides before measurement to map which proteins in signaling pathways carry a phosphate. Top-down proteomics weighs and fragments intact proteins, so it measures proteoforms whole, at lower throughput.
Require every proteomics deliverable to state the acquisition mode, the false discovery rate at peptide and protein level, how protein groups were formed and how missing values were handled, since the handling of missing values changes the downstream statistics. In biopharmaceutical work, test for host-cell proteins, the proteins left over from the cells that made the drug, by mass spectrometry as well as by immunoassay, because mass spectrometry identifies each contaminant rather than reporting a total. Where a number will support a release decision, measure it with a targeted, calibrated method that has defined limits of quantitation.
- A mass spectrometer measures mass-to-charge, and identity comes from weighing fragments as well as the whole.
- Proteins are digested into peptides, whose fragment ladders give their sequence.
- Identification is a statistical match controlled by decoys, and protein inference is its least certain step.
- Signal is not quantity, so absolute amounts need isotope-labeled internal standards.
Let's Talk