09 — Proteomics by binding

Reaching the faint end.

+ The questionWhere mass spectrometry cannot see the rare proteins in blood, how do affinity methods reach them, and what do they give up?

The sandwich immunoassay and the limit on mixing

A signaling protein such as interleukin-6 circulates in a healthy person's blood at a few picograms per milliliter, at the faint end of the range of plasma concentrations that Chapter 2 described and below the reach of the mass spectrometry of Chapter 8. A long-established way to measure a single protein at such low concentrations is the sandwich immunoassay, often called an ELISA, for enzyme-linked immunosorbent assay. One antibody fixed to a surface captures the protein, and a second antibody, which recognizes a different part of it, binds on top. The second antibody carries an enzyme that converts a colorless substrate into a colored or light-emitting product.

Two features make the method work. Requiring two antibodies to bind the same molecule makes the signal specific, because a molecule that happens to stick to one antibody rarely also binds the other. The enzyme then amplifies the signal, because each bound enzyme turns over thousands of substrate molecules, and routine assays reach picograms per milliliter this way.

The obvious next step is multiplexing, measuring many proteins in one well, and mixing many antibody pairs for it runs into a combinatorial problem. With 10 pairs in a mixture, each detection antibody can meet any of the 10 capture antibodies, which makes 100 combinations. With 100 pairs there are 10,000 possible combinations, and every one that forms by accident produces false signal. Such accidental binding is called cross-reactivity, and it limits how many antibody pairs a conventional multiplexed immunoassay can mix on its beads or spots. In a 2014 development study of a 96-protein panel, Assarsson and colleagues put that limit at around ten proteins per well, and most of the authors were employees of the company commercializing that panel. The panel itself used the method of the next section.

Turning a protein into DNA

The methods that got past that limit did it by converting the protein measurement into a DNA measurement, borrowing the copying and pairing that proteins lack (Chapter 2). In a proximity extension assay, two antibodies target each protein, and each antibody carries a short single strand of DNA. When both antibodies bind the same protein molecule, their DNA strands are held close enough to pair with each other at their tips. A polymerase then extends them into a new double-stranded DNA barcode unique to that protein, and the barcodes are copied and counted, by quantitative PCR or by sequencing.

17 — Turning a protein into DNA
target protein antibody 1 (one site) antibody 2 (another site) DNA tag signal only when two binders meet on one molecule polymerase extended into one new DNA barcode amplify and count (qPCR or sequencing) surface no partner one antibody stuck non-specifically: no barcode, no signal schematic
DNAProteinReadoutFocal detail
Plate 17 — Proximity extension converts a protein measurement into a DNA measurement. Two antibodies must land on the same molecule for their DNA tags to meet and be extended into a countable barcode — the second binder is what suppresses false signal.

The design solves the mixing problem. An antibody that sticks where it should not does no harm unless its partner also lands on the same molecule, close enough for the DNA tips to meet. Because the readout is DNA, thousands of assays can also share one tube and be read together on a sequencer. As of October 2026 the maker of the proximity extension assay specifies that its current panel measures about 5,400 proteins from 2 µL of plasma.

Solved example: the false-signal rate of two independent binders

Suppose each antibody, on its own, gives a false signal from 1 in 100 of the off-target molecules it encounters. If a signal requires two antibodies to bind the same molecule and their mistakes are independent, a false signal needs both mistakes at once, so the rate is 1 in 100 multiplied by 1 in 100, which is 1 in 10,000, a hundred times lower than either antibody gives alone. The condition matters: the mistakes are independent only if the two antibodies recognize unrelated parts of the target, and two antibodies that share a weakness, for example both binding a feature common to a protein family, lower the rate much less than this.

An approach related to the proximity extension assay adds purification steps to suppress background. Feng and colleagues described it in a 2023 development study of a panel of about 200 proteins, and several of the authors were employees and shareholders of the company that makes it. In their own comparison they reported detection limits in the attomolar range, several orders of magnitude below conventional immunoassays. At one attomolar, a milliliter holds about 600 molecules of the target.

Aptamers: binders made of nucleic acid

A second large-scale route uses aptamers instead of antibodies. Chapter 3 introduced aptamers as short folded nucleic acids that bind by shape. The aptamers used for proteomics are short single strands of chemically modified DNA, each folded into a shape that binds a particular protein. Developers find each aptamer by selection: they expose a vast random library of strands to the target, keep and copy the strands that bind, and repeat the cycle until strong binders dominate. Because the binder is itself a nucleic acid, it can be read directly by hybridization or sequencing once the unbound strands are washed away. In 2010 Gold and colleagues described an early version of one company's aptamer platform, which measured 813 proteins and read the aptamers by hybridization to a DNA microarray. Most of the authors were employees of the company that developed it.

The same company stated at the launch of a new aptamer panel in 2023 that the panel gives about 11,000 protein measurements from 55 µL of plasma, a figure that counts measurements rather than distinct proteins. An aptamer platform typically uses one binder per protein rather than a pair, so each of its measurements depends more heavily on the specificity of a single binder than a measurement that needs two binders to agree.

What each route sees

Mass spectrometry and affinity methods answer different questions, and the difference lies in how each one works rather than in how mature it is. Mass spectrometry identifies proteins by their sequence, needs no prior list, and sees modifications and variants, but it is shallow in plasma because abundant proteins consume its capacity (Chapter 8). Affinity methods reach deep into the low-abundance range, and the maker of the proximity extension assay states that its platform runs thousands of samples a week. Yet affinity methods measure only the proteins they were designed against. An affinity method's identity claim is only as good as the evidence that each reagent binds its intended target and nothing else, because the method reports whatever the reagent binds, which can include complexes, fragments or a related protein.

18 — Where each proteomics route can see
LC-MS, neat plasma — about 600 proteins per run LC-MS after depletion or nanoparticle enrichment — up to about 4,600 Affinity panels (antibody pairs, aptamers) — thousands of preselected targets deep, but only for the targets it was built to find Single-molecule protein sequencing — emerging not yet at plasma scale 100 fg 1 pg 10 pg 100 pg 1 ng 10 ng 100 ng 1 µg 10 µg 100 µg 1 mg 10 mg 100 mg per mL of plasma, log scale developers report attomolar limits, off the left end bar ends are illustrative counts: Beimers et al. 2025, which trade press says Seer initiated and part-funded; Völlmy et al. 2026, Roche staff albumin IL-6
ProteinReadoutFocal detail
Plate 18 — Mass spectrometry reads whatever is abundant without needing to know what to look for; affinity panels reach far deeper but only for the proteins they were designed against. The two routes answer different questions.

A subtle consequence matters for genetics. A genetic variant that changes the part of a protein an antibody or aptamer recognizes can change how well the reagent binds without changing how much protein is present. In a large study, that change in binding shows up as a strong genetic effect on the measured level, and it can be mistaken for real regulation of the protein.

Two affinity platforms can report different values for one protein name

When two affinity platforms each report a protein called IL-6, each reports what its own reagents bind, which may differ in which forms, fragments and complexes are captured. Published comparisons of the large platforms have found good agreement for some proteins and poor agreement for many others. In 2023, for example, Eldjarn and colleagues at deCODE Genetics compared the two large platforms and reported modest correlation between them. One platform had been used on more than 50,000 participants in UK Biobank, the cohort that the next section describes, and the other on 36,000 Icelanders. Values from different platforms are not interchangeable, and a change in platform during a study is a change in the measurement.

Proteomics at population scale

Affinity methods are what made population-scale proteomics possible, and UK Biobank shows the scale. It holds samples from about 500,000 participants, and a consortium of 13 biopharmaceutical companies funded its Pharma Proteomics Project, which measured 2,923 proteins by proximity extension in plasma from 54,219 participants. Sun and colleagues analyzed those data in 2023 and mapped more than 14,000 associations between genetic variants and protein levels. Most of the 56 named authors gave a company as their affiliation.

In January 2025 UK Biobank announced an expansion that aims to measure up to 5,400 proteins in 600,000 samples on the maker's current proximity extension panel. A consortium of 14 biopharmaceutical companies funds the expansion. The samples are one from each of the roughly 500,000 participants and 100,000 second samples taken from the same people up to 15 years later. UK Biobank plans to release the data in stages from 2026, with the full dataset expected by 2027, and the study was in progress as of October 2026. Studies like these link genetic risk to the proteins that carry it, and they are a major source of new drug targets.

The third route: reading proteins one molecule at a time

Chapter 2 noted that single-molecule detection is the one route that could remove the advantage nucleic acids enjoy, and several groups are pursuing it for proteins. One company has shipped a protein-sequencing instrument since 2023 and launched an upgraded version in January 2025. The instrument holds peptides on a chip and detects fluorescent recognizer proteins as they bind the amino acid at each peptide's exposed end, while enzymes trim the peptide one residue at a time. Reed and colleagues described the method in 2022 in a technology demonstration on synthetic peptides and protein digests, and most of the authors were the company's own scientists.

The company's newer results come from its next instrument, which had not launched as of October 2026, and the company reported them in its own announcements. In September 2026 the company reported detecting 18 of the 20 amino acids with a developmental kit run on that instrument, and in October 2026 it reported detecting 19 in the instrument's development program. The company expects to show all 20 by the end of 2026 and to launch the instrument commercially in the second quarter of 2027.

Academic groups are pursuing a different route through nanopores, the pores that some DNA sequencers read through (Chapter 5). In a 2024 bench study, Motone and colleagues at the University of Washington used a molecular motor to pull synthetic protein strands hundreds of amino acids long through a nanopore, and the electrical signal was sensitive to single amino acids. The team read the strands on flow cells made by Oxford Nanopore, and the paper's bibliographic record lists Oxford Nanopore among the study's funders. Rereading each molecule ten times raised the team's accuracy from 28 % to 61 % at telling apart strands that differed at one position, in a test with 20 possible variants where chance alone would give 5 %. The study classified known differences rather than reading an unknown sequence.

A second company takes another approach. In January 2026 it opened early access to its platform as a fee-for-service offering, starting with a tau assay that measures the protein's proteoforms, the distinct molecular forms that Chapter 8 defined. It says the platform is designed to map up to 10 billion intact protein molecules by probing each one repeatedly. The first company and the academic groups have published demonstrations, whereas the first company's newer results and the second company's design figure are the companies' own announcements. As of October 2026, none of these routes measures a plasma proteome at a depth or cost that competes with mass spectrometry or affinity methods. Chapter 24 separates what each of these routes has shown from what its developers have announced.

In practice

For an affinity measurement that will support a decision, treat each analyte as its own assay. Ask for evidence of specificity for that target, lot-to-lot consistency of the reagents, and the platform version. In a regulated product each claimed analyte needs its own analytical validation, the evidence that the test correctly detects or measures that analyte, whatever the multiplex level (Chapter 19). In a study design, fix the platform and version for the whole study, and keep aliquots for orthogonal confirmation by a targeted mass spectrometry or immunoassay method.

+ What this chapter established
  • Sandwich immunoassays reach low concentrations through two-binder specificity and enzyme amplification.
  • Proximity extension converts proteins into DNA barcodes, so thousands of assays can share one tube.
  • Affinity methods reach deep but only for predefined targets, while mass spectrometry needs no target list but is shallow in plasma.
  • Single-molecule methods have published demonstrations, but none yet measures a plasma proteome at a competitive depth or cost.