+ Part VIII · The field in 2026
Owners, products and the next decade.
On 30 January 2026 Illumina completed its purchase of SomaLogic from Standard BioTools, and with the sale the aptamer platform of Chapter 9, whose binders are short strands of chemically modified DNA, passed to a company that sells sequencers. Thermo Fisher Scientific, whose Orbitrap mass spectrometer Chapter 3 describes, had completed its purchase of Olink, the maker of the proximity extension assay, on 10 July 2024. By 2026, therefore, both of the large affinity platforms that Chapter 9 compares belonged to makers of other kinds of instrument: a maker of sequencers and a maker of mass spectrometers. Illumina paid $350 million in cash for SomaLogic at closing, with up to $75 million more in milestones and royalties tied to performance. Six months later, in July 2026, Standard BioTools stated that Illumina had agreed to pay it about $30 million to buy out the performance payment for 2026 and the future royalties. Owners, product names and regulatory records in this field change within months, so this part gives every status as of October 2026. Chapter 23 sets out who builds and sells the instruments, kits and tests of each layer and which of them hold a regulator's decision, and Chapter 24 separates the changes likely in the next decade from the limits likely to remain.
Who builds omics, by technique.
+ The questionWho builds and sells the instruments, kits and tests of each omics layer in October 2026, and which of them has a regulator examined?
At least nine changes of owner since May 2024
At least nine omics businesses changed owner between May 2024 and July 2026, SomaLogic among them, and in October 2026 two more sales were waiting to close. Several of these businesses make products that earlier chapters describe, often without naming the maker: the proximity extension and aptamer panels of Chapter 9, the flow cytometers of Chapter 11, the imaging panels and split-pool kits of Chapter 12 and the EV-based prostate test of Chapter 14. The table lists each change with two dates kept apart, the day the agreement or the purchase was announced and the day the purchase was completed. A dash marks an announcement date that the buyer's release or filing on the completion does not give, and the dates in one row come from a news report.
| Business bought | Products named | Buyer | Agreed or announced | Completed |
|---|---|---|---|---|
| NanoString's business, as assets | nCounter, GeoMx, CosMx | Bruker | — | 6 May 2024 |
| Olink | proximity extension panels | Thermo Fisher Scientific | — | 10 July 2024 |
| Akoya Biosciences | PhenoCycler, PhenoImager | Quanterix | — | 8 July 2025 |
| Exosome Diagnostics, from Bio-Techne | ExoDx Prostate, with a CLIA-certified laboratory | mdxhealth | 5 August 2025 | 15 September 2025 |
| Parse Biosciences | Evercode single-cell kits | Qiagen | — | 2 December 2025 |
| SomaLogic, from Standard BioTools | SomaScan | Illumina | — | 30 January 2026 |
| BD's Biosciences and Diagnostic Solutions businesses | flow cytometry and single-cell products, now sold as Waters Biosciences | Waters | — | 9 February 2026 |
| Exact Sciences | Cologuard, Oncotype DX, Oncodetect, Cancerguard | Abbott | — | 23 March 2026 |
| Naveris | NavDx | CareDx | April 2026 (news report) | July 2026 (news report) |
| Proteintech Genomics, from Proteintech Group | an antibody panel for single-cell protein | 10x Genomics | 9 June 2026 | not stated |
| Complete Genomics | DNBSEQ sequencers | Swiss Rockets | 23 February 2026 | pending, October 2026 |
| Standard BioTools' mass cytometry business | CyTOF, Hyperion | Element Biosystems | 30 September 2026 | pending, October 2026 |
Some businesses and products took new names through these sales. BD's biosciences business has traded as Waters Biosciences since 9 February 2026, and Illumina's release on the SomaLogic purchase states that Illumina Protein Prep is now called Illumina SomaSeq Discovery. A sale can also leave the seller with rights: when Bio-Techne announced the sale of Exosome Diagnostics on 5 August 2025, it stated that it would retain access to that company's vesicle technology for developing kits. Five of the completed purchases joined a business to a buyer that sells another kind of instrument. A sequencer maker bought an aptamer platform for proteins, three makers of mass spectrometers bought an affinity platform, a spatial business and a cytometry business, and a maker of immunoassays bought a company that images proteins in tissue.
The sections that follow take the layers in the order of the book and keep three kinds of statement apart. Any specification, price, count or claim to be first that a company makes stays labeled as that company's, unless a regulator's record supports it. A regulator's decision is given with its date and the regulator's verb, which Chapter 21 introduced: the FDA clears a premarket notification, or 510(k), grants a De Novo request, and approves an application for premarket approval, or PMA. A product in the laboratory research phase, which its maker does not offer for diagnosis, is labeled research use only, with the statement that the FDA's labeling regulation sets for such products: "For Research Use Only. Not for use in diagnostic procedures." The sections below give that label only where a maker states it. Chapter 25 gives the regulation, and every status in this chapter is as of October 2026.
Sequencers, and the kits that read marks on DNA
Illumina's NovaSeq X Series is one of the production-scale short-read sequencers whose output Chapter 5 gives in terabases. Illumina specifies about 8 to 10.5 terabases from its 25B flow cell in a run that reads 150 bases from each end of every fragment, with at least 85 % of the bases above Q30, the quality score of Chapter 4. The company states a $200 genome at list price on that flow cell, without stating the coverage or what the figure includes. On 19 November 2013 the FDA granted De Novo requests for Illumina's MiSeqDx instrument and a universal reagent kit, and it cleared two cystic fibrosis assays that run on them.
Other makers launched or announced short-read instruments in 2025 and 2026, each with its own figures. Element Biosciences announced its VITARI system on 19 February 2026, with up to 10 billion reads per run and a system price of $689,000, and as of October 2026 the system was on pre-order for shipping in the second half of the year. The company calls VITARI the first high-throughput benchtop system to deliver a high-quality whole genome at $100, and its release does not say what the $100 covers. Ultima Genomics put its UG200 Series on sale in February 2026, at US list prices of $1,250,000 for the UG200 Ultra and from $850,000 for the standard UG200, with shipments from the second quarter. On 20 October 2026 Ultima launched its Solaris 2.0 Max consumables for the UG200 Series and for the earlier UG100, and the company states that they enable a $60 whole human genome at 30× coverage. Its release does not say what the $60 covers. Roche launched AXELIOS 1, the sequencing-by-expansion system of Chapter 5, on 29 June 2026 at a US system price of $750,000. Roche states a mean raw read accuracy above 99.3 % and describes two modes. In the duplex mode the two strands of each molecule are linked during library preparation, so that their reads can be combined for accuracy. The simplex mode is built for throughput, and for it Roche states reads of up to 1,500 bases under suitable sample and library conditions. Roche labels the system for research use only and publishes no cost per genome.
Complete Genomics unveiled the DNBSEQ-T1+ and DNBSEQ-E25 Flash sequencers in February 2025, and on 23 February 2026 it agreed to be acquired by Swiss Rockets, a company based in Basel. Complete Genomics is the US subsidiary of MGI Tech. The agreement required the approval of MGI Tech's shareholders, and on 19 August 2026 Complete Genomics reported that they had given it. The purchase still needed clearance from the Committee on Foreign Investment in the United States, which reviews foreign investment in US businesses, and as of October 2026 the sale was pending.
A US law will limit federal business with some sequencer makers. The BIOSECURE Act became law on 18 December 2025 as section 851 of the defense authorization act for 2026, a section titled "Prohibition on contracting with certain biotechnology providers". On 10 December 2025, before the act was signed, the law firm Covington & Burling published a summary of the act's final text. Covington describes the prohibition as applying to federal agencies, and to their contractors and subcontractors in the work they do on federal contracts. By Covington's reading, the act does not bar a contractor from all business with a biotechnology company of concern, the act's term for a provider it covers. In a summary of January 2026 the law firm Ropes & Gray notes that the act names none of BGI, MGI or Complete Genomics, and that a company can come under it through a Defense Department list of Chinese military companies. The list that the department published in June 2026 names BGI Group, with Complete Genomics among its subsidiaries, and MGI Tech, while the earlier list that Ropes & Gray described did not name Complete Genomics. The government's own list of biotechnology companies of concern is due by 18 December 2026, and the act's prohibitions take effect only after the federal acquisition rules are revised.
PacBio and Oxford Nanopore make the long-read sequencers of Chapter 5. PacBio states that its SPRQ-Nx chemistry for the Revio system has shipped worldwide since 26 May 2026, at a list price of about $345 for a human genome at 20× coverage, and under $300 for a laboratory sequencing 5,000 genomes a year with discounts. The company states that these figures cover sequencing reagents only, leaving out the instrument, library preparation and labor. It gives its HiFi reads as typically 15,000 to 20,000 bases long and 99.9 % accurate, with methylated cytosines read from the kinetics of the polymerase. PacBio is also the maker in Chapter 24 that announced, on 4 November 2025, a Class III registration in China for its Sequel II CNDx system, and the "world's first regulatory clearance of a clinical-grade long-read sequencer" is PacBio's own description of it.
Ultima Genomics lists the UG200 Ultra at $1,250,000 and states that one instrument can sequence up to 60,000 whole genomes a year at 30× coverage with its Solaris 2.0 Max consumables. The cost series of the National Human Genome Research Institute, in Chapter 5, spreads the price of a sequencing instrument over three years, and on that rule the instrument costs about $417,000 a year. Dividing $417,000 by 60,000 genomes gives about $7, so at the company's full volume the instrument adds about $7 to each genome, on top of the reagent price. Because 60,000 is the most the company states, $7 is the least the instrument adds, and only an instrument that runs at full capacity all year reaches it. At 6,000 genomes a year, a tenth of that volume, the instrument adds about $70 to each genome, and at 600 genomes about $695, so what the instrument itself adds depends on how many genomes a laboratory runs.
Oxford Nanopore states a raw read accuracy of 99.75 % with its latest basecalling software, and reads longer than 100,000 bases. In January 2026 it announced that its GridION Dx instrument carries the CE and UKCA markings, under which a device is sold in the European Union and in Great Britain, and called it the company's first diagnostic device registered in the UK and Europe. The announcement names no device class and no notified body, the independent assessor of Chapter 26, so it does not show whether the company declared the marking itself or had it certified. The first application the company names is the characterization of infectious disease, offered through specified partners, and it states that its tuberculosis assay, AmPORE-TB, remains for research use only.
Methylation is read either after a conversion step or directly from the native molecule, and makers sell both routes (Chapter 6). Illumina specifies that its Infinium MethylationEPIC v2.0 array targets about 930,000 methylation sites from 250 ng of DNA, with eight samples on each array. New England Biolabs sells the enzymatic conversion kit of Chapter 6 as the NEBNext Enzymatic Methyl-seq v2 Kit, which it specifies for inputs of 0.1 to 200 ng. The paper that Chapter 6 reads on the method was written by the company's staff and funded by the company. On 15 October 2025 Illumina released a "5-base solution", which it states detects genetic variants and DNA methylation from one sample, the kind of method that Chapter 24 dates to 2025. Among the native readers, Oxford Nanopore gives 99.2 % accuracy for its methylation calls on synthetic DNA whose marks are known. RNA sequencing runs on the same instruments, with library kits from many reagent makers (Chapter 7).
Mass spectrometers, binding panels and metabolite services
Makers of mass spectrometers launch new instruments at the yearly conference of the American Society for Mass Spectrometry, and trade publications report the makers' figures. At the 2025 meeting in Baltimore, Thermo Fisher Scientific launched the Orbitrap Astral Zoom, which it describes as scanning up to 270 times a second. Bruker launched the timsUltra AIP, the timsOmni and the timsMetabo, which it describes as scanning up to 300 times a second, and SCIEX launched the ZenoTOF 8600, which it says has ten times the sensitivity of its earlier ZenoTOF instruments.
At the 2026 meeting in San Diego, from 31 May to 4 June, Thermo Fisher introduced the Orbitrap Tribrid Apex, which a trade report describes as collecting data four times faster. Waters introduced the Xevo MRT P10 and states that it gives up to 20 times more sensitivity in fragment scans. Bruker introduced the timsMRMS, and Shimadzu introduced software for untargeted metabolomics and lipidomics. None of these reports gives samples per day or a count of proteins identified, and the number of proteins an instrument finds in plasma depends on the sample and the method as well as on the instrument (Chapter 8).
Other companies sell the steps before the spectrometer. Seer sells one form of the nanoparticle enrichment of Chapter 8. It states that proteins from a sample bind to its engineered nanoparticles as a layer called a protein corona, and that the binding compresses the sample's dynamic range. Seer launched its Proteograph ONE assay and SP200 automation instrument at the 2025 meeting, and a trade report gives Seer's claim that the instrument processes more than 1,000 samples a week, with an automated run of under 5 hours. Evosep, which makes separation systems for proteomics, launched its Eno platform the same year and states that its standardized methods run between 30 and 500 samples a day. Throughputs of this kind lie behind Chapter 24's "hundreds of samples a day", and they are the makers' own figures.
Olink makes the proximity extension assay of Chapter 9, SomaLogic makes the aptamer platform, and UK Biobank's expansion measures up to 5,400 proteins on Olink's Explore HT platform. Alamar Biosciences makes the method of Chapter 9 that is related to the proximity extension assay and adds purification steps, and it sells NULISAseq panels whose names give their protein counts: Neuro 220, CNS Disease 120, Immune 340, Inflammation 250 and a mouse panel of 120. Alamar's site marks its products for research use only. In July 2026 the company announced that it would profile about 21,000 plasma samples from 10,000 participants in dementia studies with its Neuro 220 panel, for a consortium funded by the US National Institute on Aging, and that the data would be public.
Quantum-Si and Nautilus Biotechnology are the two companies of Chapter 9 that read proteins one molecule at a time. Quantum-Si sells the Platinum protein sequencer, and Chapter 9 reports its development results for the next instrument, Proteus, which the company expects to launch in the second quarter of 2027. In its second-quarter results of 28 July 2026, Nautilus stated that its Voyager platform was not yet commercially available. It expected to take pre-orders in early 2027 and to ship instruments in mid-2027 with kits for measuring proteoforms, and it said that the timeline for its assay of the broad proteome would be reported later.
Metabolon and biocrates sell metabolomics of the kinds Chapter 10 describes, as services and as kits. Metabolon runs its services on liquid chromatography with tandem mass spectrometry, and it states that its untargeted panel covers up to 70 major biochemical pathways and that its targeted panels give absolute amounts for more than 1,000 metabolites and lipids. The company gives its reference library as over 5,400 metabolites and calls it the world's largest, and it also sells a profiling kit, Verus. The Innsbruck company biocrates sells targeted kits such as the MxP Quant 500 and the AbsoluteIDQ p180, as well as services, and its logo carries the words "Biognosys group" without the site explaining the link. Both companies state that their products and services are for research use only.
Cytometers, single cells and tissue sections
The flow cytometers of Chapter 11 come from several makers. The spectral instrument used for Chapter 11's 50-color panel came from BD Biosciences, which is now Waters Biosciences. Waters gained that business through a combination in which BD's biosciences and diagnostic businesses were separated from BD and merged with a Waters subsidiary, and the diagnostic business joined Waters Advanced Diagnostics. Cytek Biosciences is the manufacturer that Chapter 11 says placed a 60-color instrument in early access in 2026. It announced the Borealis spectral cytometer, with 7 lasers and 120 detectors, on 2 June 2026, for a debut at the CYTO 2026 meeting.
The FDA cleared BD's FACSLyric flow cytometer system, with its clinical software and assays, on 3 July 2017, and cleared it again on 28 September 2020 with a sample-preparation system and further optical configurations. As of October 2026 the FDA's database lists Becton, Dickinson and Company as the applicant for both clearances, and the FDA's registration records name the same company as the owner of the sites that list the system. Waters' announcement of its combination names no instrument, and neither kind of record shows whether the clearances have passed to the new owner. A search of the database under Waters' name therefore misses both records, and a check of a product's regulatory status has to search every name its maker has carried.
Mass cytometry, the metal-tag method of Chapter 11, belongs to Standard BioTools, which sells the CyTOF and Hyperion instruments. On 30 September 2026 Standard BioTools ended an agreement of July 2026 to sell that business to Multiplex Bio, and agreed instead to sell it to Element Biosystems, an acquisition company that GMT Venture Partners formed. Element Biosystems is a different company from the sequencer maker Element Biosciences. Standard BioTools expects the sale to close by the end of 2026, together with its own merger with Treeline Biosciences and subject to its stockholders' approval, and until then it remains the seller of both instruments.
10x Genomics makes the Chromium droplet systems of Chapter 12, and it is the maker that stated in October 2024 that its GEM-X Flex chemistry profiles up to 2.5 million cells per run, at as little as one cent a cell. On 9 June 2026 it announced the purchase of Proteintech Genomics, a division of Proteintech Group, without disclosing terms, and it calls that division's antibody panel the largest of its kind for single-cell protein. Qiagen now owns Parse Biosciences, the maker of the split-pool Evercode kits of Chapter 12, which need no instrument, and Waters Biosciences now sells the single-cell multiomics products that BD sold.
Bruker has sold NanoString's spatial and gene-expression instruments since it bought that business's assets in 2024, through a unit now called Bruker Spatial Biology. The unit's products are the CosMx imager, the GeoMx profiler, the nCounter system and CellScape, and its site labels them for research use only. The imaging panels of Chapter 12 that reached about 6,000 genes in 2024 and the whole transcriptome in 2025 are CosMx panels. Chapter 12's 5,000-gene panel is 10x Genomics' Xenium Prime 5K, launched in May 2024 for 10x's own imaging instrument. 10x introduced Atera on 18 April 2026 and describes it as a platform for whole-transcriptome spatial analysis with single-cell sensitivity. On 29 September 2026 the company announced its first commercial shipments of Atera, and neither that announcement nor the one at launch gives a price or a research-use statement.
In 2025 Quanterix, which sells its own Simoa immunoassays, bought Akoya Biosciences, the maker of the PhenoCycler and PhenoImager systems for spatial proteomics. Vizgen, the private maker of the MERSCOPE imager, launched new panels and segmentation tools in April 2026, and its news page lists a report that it raised $48 million in January 2026. Two sequencer makers have spatial plans as well. Complete Genomics agreed in March 2025 to supply Stereo-seq spatial transcriptomics to the Human Cell Atlas, and Element Biosciences lists direct spatial sequencing in tissue on its AVITI24 system as a plan rather than a launched product.
Blood and tissue tests that hold FDA decisions
The colorectal blood tests of Chapters 14, 21 and 22 that the FDA approved in 2024 and 2026 come from two companies. Guardant Health's Shield was approved on 26 July 2024, and its change to a methylation-only model on 22 July 2026 (Chapter 25). Freenome's SimpleScreen CRC was approved on 24 July 2026, four days after Freenome became a company listed on Nasdaq through a merger with Perceptive Capital Solutions, a listed company formed to acquire a private one. Freenome's filing on the listing includes a collaboration and license agreement with Exact Sciences dated 3 August 2025, without stating its terms or which company markets the test. Exact Sciences, part of Abbott since March 2026, holds the FDA's approvals of two earlier colorectal screening tests that analyze stool: Cologuard, approved on 11 August 2014 for adults aged 50 and older, and Cologuard Plus, approved on 3 October 2024 for adults aged 45 and older at average risk.
Abbott's announcement of the purchase also names Oncodetect, which it describes as a tumor-informed test for molecular residual disease, and Cancerguard, a blood test for detecting many cancers, without giving their regulatory status. The FDA's PMA records under Exact Sciences' name include neither of the two. GRAIL's Galleri, the multi-cancer test of Chapters 22 and 25, was awaiting the FDA's decision on its PMA as of October 2026.
The profiling tests of Chapter 21 come from three makers. Foundation Medicine holds approvals for FoundationOne CDx, a tissue test of 324 genes approved on 30 November 2017, and for FoundationOne Liquid CDx, a plasma test of 311 genes approved on 26 August 2020. Guardant Health holds approvals for Guardant360 CDx, a plasma test approved on 7 August 2020, and for Guardant360 Liquid CDx, a plasma panel of 741 genes approved on 19 May 2026. Illumina holds the approval of 21 August 2024 for TruSight Oncology Comprehensive, the distributable kit of Chapter 21. Natera's Signatera CDx, approved on 15 May 2026, is the residual-disease companion diagnostic of Chapter 21. Its PMA is the only one in the FDA's database under Natera's name, so Signatera outside its approved use, and Natera's other tests such as its prenatal screen, carry no FDA approval on that record.
Four of the FDA's decisions in this chapter, all on new tests, came within about ten weeks in 2026: the clearance of an Indian company's profiling test on 12 May, described below, the two approvals of 15 and 19 May, and the approval of SimpleScreen CRC on 24 July. A news service reported that CareDx completed its purchase of Naveris in July 2026. Naveris's NavDx test detects tumor-derived circulating DNA to monitor cancer, and the report gives no regulatory status for it. The plate below gathers the FDA's decisions on the products in this chapter.
No test built on extracellular vesicles appears among these decisions. Since September 2025 mdxhealth has owned the ExoDx Prostate test, together with a CLIA-certified laboratory. The test is the EV-based one whose 2019 designation Chapters 14 and 25 describe, and mdxhealth now sells it as Exo mdx. The company states that the test combines the expression of three genes, PCA3, SPDEF and ERG, measured in RNA from EVs in urine collected without a rectal examination. Neither mdxhealth's announcement nor Bio-Techne's states the test's FDA status, and the search reported in Chapter 14 found no FDA clearance or approval of an EV-based diagnostic as of October 2026.
India: service laboratories, one clearance and a national data set
The Indian companies in this chapter run laboratories that sequence samples and report results, and the figures that follow are their own. MedGenome, which runs laboratories in Bangalore and in Foster City, California, raised $47.5 million in July 2025 in a funding round led jointly by Maj Invest and Novo Holdings. The announcement, from Novo Holdings, carries MedGenome's description of itself: more than 1,300 genetic tests, more than 500,000 genomes and exomes sequenced over the last decade, and a Bangalore laboratory that MedGenome calls the largest genetic testing laboratory in India accredited by CAP, the US accreditation body of Chapter 19. Strand Life Sciences, also in Bangalore, sells clinical sequencing reports for inherited and tumor variants, software for omics and biomarker services for drug companies. It states that its sequencing laboratory is accredited by CAP.
4baseCare, a third Bangalore company, profiles tumor tissue and circulating tumor DNA, and states that it has mapped more than 30,000 genomic profiles. Mapmygenome sells consumer and clinical genomic tests, among them a whole-genome sequence at 89,000 rupees without the raw data. Its site describes its laboratory as accredited by NABL and certified to the 2012 edition of ISO 15189, an edition that ISO has superseded and that Chapter 27 shows NABL no longer accredits against.
An Indian company received an FDA clearance for an omics test in 2026. On 12 May 2026 the FDA cleared CellDx-Tissue, a sequencing-based tumor profiling test from Datar Cancer Genetics of Nashik, by a 510(k) that went through third-party review, in which an organization accredited by the FDA reviews the submission before the agency decides. It is the clearance that Chapter 25 cites under the classification "Next Generation Sequencing Based Tumor Profiling Test". Datar describes itself as "India's only US FDA-cleared comprehensive genomic profiling assay provider", and that claim is the company's own. The clearance covers CellDx-Tissue alone. The company also sells two blood tests, one for detecting tumors in suspected cases and one for screening people without symptoms, and no FDA record for them was found under the company's name. Datar states that its laboratory in Nashik is CLIA-certified and CAP-accredited, and that a second laboratory, in Guildford, England, is registered with the Care Quality Commission, England's regulator of health and social care.
The national genome data set of Chapter 4 comes from GenomeIndia, a project funded by the Department of Biotechnology, and holds about 10,000 whole genomes. A search for this guide in October 2026 found no Indian maker of a sequencer, mass spectrometer, cytometer or omics kit, and returned procurement tenders, distributors and market reports instead. One search cannot show that no such maker exists, and it left out makers of PCR and immunoassay kits, whose techniques lie outside this chapter. A test kit made or imported for sale in India needs a license under the Medical Devices Rules of 2017, and Chapter 27 sets out who issues it and what research use only means there.
Before a product goes into a design and development file, a study protocol or a business plan, record four facts about it, each dated on the day it was confirmed. Name the present owner and the date of the last change of owner, and treat an agreed sale as pending until its completion is announced. Copy the product's label, and where it says research use only, plan for the laboratory to establish the test's performance itself (Chapter 19). Find the regulator's record under every name the product and its maker have carried, and copy the decision, its date and the regulator's verb. Mark each specification, price and count that comes from the maker as the maker's own.
- At least nine omics businesses changed owner between May 2024 and July 2026, five of them joining a buyer that sells another kind of instrument, and the sales of Complete Genomics and of Standard BioTools' mass cytometry business were pending in October 2026.
- Makers launched or announced several sequencers in 2025 and 2026, whose prices and per-genome figures are the makers' own, and a $1,250,000 instrument spread over three years adds about $7 a genome at its maker's maximum of 60,000 a year but about $695 at 600, so what it adds depends on how fully it is used.
- Among the products in this chapter, the FDA's decisions belong to cancer and cystic fibrosis tests, one sequencing instrument with its reagent kit and one flow cytometer system, while the spatial, protein-panel and metabolomics products whose labels are given here are for research use only.
- India's omics companies in this chapter run laboratories, and one of these companies received an FDA clearance on 12 May 2026; a search in October 2026 found no Indian maker of omics instruments or kits.