+ Part V · The case

Reading the twins.

The combined paper of April 2019 reports that, of the genes whose expression changed during flight in three fractions of the flight twin's blood cells, 91.3 % had returned to normal ranges within six months of landing, and the rest had not. In 2018, NASA's account of the preliminary results had put the two shares at 93 % and 7 %, the figures of the opening story. This part reads the NASA Twins Study with every layer of the guide in hand: first its design and the limits of a study of one pair of people, then layer by layer, then across layers. It answers in full the first clause of the central question: what each omics layer records that the genome cannot.

15 — The layers together

What the layers showed together.

+ The questionWith the genome held constant, what did combining the layers reveal that no single layer could?

The design, and why it suits the question

On 12 April 2019 the journal Science published the combined results of the NASA Twins Study, a paper by Garrett-Bakelman of Weill Cornell Medicine and 81 co-authors. The study was a case study of a single pair, followed over time: one of a pair of identical twins spent 340 days on the International Space Station, while his brother stayed on Earth. Over 25 months the investigators collected 317 samples from the two brothers before, during and after the flight, among them blood, urine and stool, and they measured the layers of this guide alongside physiology and cognition. NASA's Human Research Program ran the study and led its funding, with further support from US and German research agencies and private foundations. Five of the authors declared roles in companies, as founders, board members, advisers or consultants.

Identical twins start from one fertilized egg, so the ground twin is as close to a genetic control as biology allows. With the inherited genome held constant, every difference the study found had to lie outside the inherited sequence. The investigators also took a step that the chapters on cells anticipated. They separated blood with magnetic beads into four fractions of immune cells, measured RNA in each sorted fraction, and measured methylation in the two fractions that held T cells, one family of white blood cells. Without that step a change in the mixture of cells would have looked like a change inside cells, the averaging problem of Chapter 11.

The design also has obvious limits, and reading it well means keeping them in view. The study followed one pair of people and tested thousands of molecular features at once. Among them were the expression of genes across the genome, 62 cytokines and 4,162 metabolic features in plasma. Cytokines are signaling proteins of the immune system, and the metabolic features are the detected signals of Chapter 10. The authors corrected every result for multiple testing, holding the false discovery rate at 5 % or 1 %. That rate is the expected share of false findings among those reported, so some differences will be chance even after the correction, and Chapter 18 explains how the correction works.

Spaceflight also bundles many exposures together, including microgravity, radiation, confinement, diet and disrupted sleep, and a single case cannot say which one caused a given change. The authors themselves write that, with one person in flight, a change cannot be attributed to spaceflight rather than to coincidence. They call the study hypothesis-generating and write that studies of additional astronauts must complement it.

Layer by layer

The inherited sequence did not change, as expected, but one finding qualifies that statement. The flight twin's blood cells showed more chromosomal rearrangements, such as inversions, during flight, and some were still present after return. Those rearrangements arose during life, in some cells only, and they left the inherited genome as it was. Changes of this kind show that "the genome is constant" is true of the germline, the cells that pass the genome to children, and only approximately true of every cell.

30 — The same genome, measured for 25 months
NASA Twins Study (Science, April 2019) · identical twins one spent 340 days on the ISS; the other stayed on Earth as the control LAYER IN FLIGHT 6 MONTHS AFTER LANDING Inherited genome sequence unchanged unchanged Epigenome (DNA methylation) shifted (immune, oxidative-stress genes) largely back Transcriptome (gene expression) many genes changed most returned; a minority stayed changed Telomeres lengthened mostly reverted; more short telomeres Proteome changed substantial recovery Metabolome changed substantial recovery Microbiome (gut) composition shifted near preflight Cognition similar to preflight some decline persisted methylation: the genome-wide shifts stayed within the range of variation seen in the ground twin the inherited sequence did not change
DNARNAProteinMetaboliteModificationFocal detail
Plate 30 — The investigators followed one pair of identical twins for 25 months, through a year in orbit. The inherited genome sequence was the constant; nearly every other layer moved, and most moved back. What persisted — in gene expression, telomere lengths, chromosomal rearrangements in blood cells and cognition — lies outside the inherited sequence.

DNA methylation shifted in flight in the two kinds of T cell measured, including at genes involved in immune function and oxidative stress, and largely returned after landing. The paper reports that these genome-wide changes stayed within the range of variation seen in the ground twin, whose methylation changed more over the study and did not fully return to baseline. What set the flight twin apart were changes at the promoters of particular genes, the regions where transcription starts, in groups of genes that did not stand out among the ground twin's changes.

Expression changed for many genes during flight, and most returned to preflight levels within six months while a minority remained changed. Of the genes whose expression changed in three of the sorted fractions, the paper puts the share that returned to normal ranges within six months at 91.3 %.

The telomeres, the protective ends of chromosomes, lengthened in blood cells during flight, by 14.5 % on average, then shortened within about 48 hours of return, leaving more short telomeres than before the mission. In 2019 the authors described the mechanism and the potential consequences of this temporary lengthening as unknown. Protein and metabolite patterns in blood and urine changed in flight, in directions consistent with fluid shifts and physiological stress, and recovered substantially after landing. The composition of the gut community shifted in flight and returned close to its preflight state within six months. The flight twin's cognitive efficiency, measured against the ground twin's, was similar in flight to its preflight level, then declined after return and had not fully recovered at six months. Cognition is not a molecular layer, but it is the observable outcome, or phenotype, that the molecular layers are ultimately trying to explain.

What the combination revealed

Two things were visible only because many layers were measured together. The first is that agreement across layers is evidence, because a shift in immune and stress-response genes seen in methylation, in expression and in proteins is far harder to dismiss as chance than the same shift seen in one data set of thousands of comparisons. A finding in a single layer is therefore a hypothesis, while the same finding in independent layers is an argument.

The second is that the layers moved on different clocks, and not simply the clocks Chapter 1 would suggest. Metabolites, gut microbes and most transcripts responded and recovered quickly, but so did most of the methylation changes. What persisted was a subset of the changes in gene expression, the distribution of telomere lengths, rearrangements carried by long-lived blood cells, and cognition. Timing across layers is information that no single layer holds.

Where the paper sets protein beside RNA, it reports consistency rather than divergence. Collagen proteins rose in the flight twin's urine during flight, and the authors describe that rise as consistent with the raised expression of collagen-related genes in his blood cells. The protein came from urine and the RNA from blood cells, so the comparison shows two layers moving in one direction, and it cannot show how closely one gene's protein follows its own RNA. In general the two need not move together, because of how cells work, and the next section sets out why.

Why RNA does not predict protein

Across genes, the amount of messenger RNA predicts the amount of protein only partly. In an early genome-wide study, published in 2011, Schwanhäusser and colleagues in Berlin measured RNA and protein for more than 5,000 genes in mouse fibroblasts, and found that RNA levels explained about 40 % of the variation in protein levels between genes. They reached that figure on the assumption that their measurements carried no noise. Chapter 1 uses the same study for the half-lives of RNA and protein. In a 2014 reanalysis from the University of California, Berkeley and Lawrence Berkeley National Laboratory, Li, Bickel and Biggin corrected the same data for measurement noise, and for 4,212 genes they put the share considerably higher, at 56 to 84 %.

31 — RNA is not protein
protein level (log) mRNA level (log) fast protein turnover secreted — leaves the cell long-lived protein little mRNA, much protein schematic · across genes, mRNA explained about 40 % of protein variation in an early genome-wide study (2011); a 2014 reanalysis correcting for measurement noise gives 56 to 84 %
ReadoutFocal detail
Plate 31 — Knowing how much RNA a gene makes predicts its protein level only partly. Translation rates, protein lifetimes and secretion all intervene, which is why proteomics cannot be inferred from transcriptomics and must be measured.
Solved example: the share of protein variation that RNA does not explain

In the 2011 study, RNA level accounted for about 40 % of the differences in protein level between genes, which leaves 100 − 40, or about 60 %, to the steps after transcription and to measurement noise together. The 2014 reanalysis corrects the same data for measurement noise and puts the share that RNA accounts for at 56 to 84 %, and subtracting each end of that range from 100 leaves between 16 and 44 % that RNA level does not account for. Even the highest estimate therefore leaves about one sixth of the gene-to-gene differences in protein level to the steps after transcription, such as translation and protein lifetime, and to any noise the correction missed.

Changes in RNA over time within one gene predict changes in its protein much less well, and changes over time are what the Twins Study measured. The reasons are the control points of Chapter 1. Genes differ in how efficiently their RNA is translated, and proteins differ in how long they last. In the mouse cells of the 2011 study, the protein half-lives that could be measured ran from under half an hour to more than 200 hours, so a long-lived protein can stay abundant long after its RNA has fallen. Secreted proteins leave the cell that made them, and a protein's activity can be switched by modification with no change in amount at all. RNA therefore shows what a cell is preparing to do, protein shows what it has, and activity and metabolites show what it is doing, so none of these measurements substitutes for the others.

How layers are combined

Integration methods, which combine the layers in one analysis, fall into three families. Early integration joins all measurements into one table and analyzes it together, which is simple but lets the largest data set dominate. Late integration analyzes each layer separately and combines the conclusions, which respects each layer's statistics but misses relationships between them. Intermediate integration looks for a small number of hidden factors that explain variation across all layers at once, and it is widely used for studies with many samples.

Genetic variation adds a fixed reference point, because inherited variants do not change with the state of the cell. When a genetic variant is associated with the level of an RNA, a protein and a metabolite in the same direction, and with a disease, the chain from code to phenotype can be traced step by step across a population. The large population studies of Chapters 9 and 21 measure several layers in the same people for that reason.

Integration can find structure in pure noise

Every added layer adds thousands of measurements and therefore thousands of chances for coincidence. Integration methods are powerful enough to find structure in pure noise. Multi-omics strengthens a conclusion when the layers were planned together and measured on the same samples, and when agreement across them was predicted before the data arrived, not discovered afterward.

What each layer records that the genome cannot

The central question asks first what each omics layer records that the genome cannot. The twins supply the answer in miniature, and the chapters before this one supply the mechanism. The table's last column gives the typical time over which each layer changes; single molecules can be faster or slower, as the range of protein half-lives above shows.

LayerWhat it records that the genome cannotHow it is readClock
Epigenomewhich parts of the genome a cell keeps available, and remembers through divisionsequencing after conversion, enzymes, antibodies, native long readsminutes to years
Transcriptomewhich genes are being read now, and how intenselycounting cDNA fragments by sequencingminutes to hours
Proteomewhich molecular machines exist, in which modified formsmass spectrometry, affinity bindinghours to days
Metabolomewhich chemistry is actually running, including diet, drugs and microbesmass spectrometry, NMRseconds to minutes
Cytome and single-cellwhich cells are present and in which states, rather than an averagecytometry, barcoded single-cell sequencingper cell
Spatialwhere each cell and molecule sits in the tissuecapture arrays, in situ imagingfixed at sampling
Microbiomethe genomes and activity of the organisms living alongside usmarker-gene and shotgun sequencingdays to weeks
Cell-free DNA and EVswhich tissues are releasing material now, and what it carriesdeep sequencing, methylation, single-particle countingminutes to hours

Each layer is a different record of state laid over the same code. The layers differ in cost and difficulty for a physical reason, whether their molecules can be copied and read by pairing, and that answers the central question's second clause. They differ in meaning because each sits at a different control point between instruction and function. Parts VI to IX take up the third clause: what it takes to turn one of these measurements into a result someone can act on.

In practice

Plan a multi-omics study as one study, not several. Take all layers from the same collection at the same time, split the sample into aliquots before any layer-specific processing, and record the metadata every layer will need: time of collection, time to processing, storage and batch, the group of samples processed together. Decide in advance which cross-layer agreements would count as confirmation. Budget for the integration analysis as well, because it is often the most expensive part.

+ What this chapter established
  • With the genome held constant, the flight twin's layers shifted in flight and mostly recovered, and a subset of changes persisted.
  • Agreement across independent layers turns a single-layer hypothesis into evidence.
  • RNA predicts protein only partly, because translation, lifetime, secretion and modification intervene.
  • Each layer records a different part of the cell's state over the same code, which answers the first clause of the central question.