12 — Single-cell and spatial omics

Every cell, and where it sat.

+ The questionCan we read the whole transcriptome of each cell, and still know where in the tissue it came from?

Labeling instead of separating

In November 2024 the Human Cell Atlas consortium published a collection of its studies in Nature, and its data portal then held data on about 62 million individual cells from about 9,100 donors. Data of that kind needed a different method from cytometry, because measuring the whole transcriptome of each cell is a problem of a different scale from measuring dozens of proteins per cell. A single cell holds only about 10 pg of RNA, and early methods handled one cell per tube, which limited studies to hundreds of cells. The methods that scaled to millions did so by separating cells only long enough to label them. If every RNA molecule from one cell carries the same DNA tag, all the cells can be pooled and sequenced together, and the reads can be sorted back into cells afterwards.

A widely used implementation uses droplets: a microfluidic chip combines a stream of cells, a stream of gel beads and oil, and produces thousands of droplets per second. Every bead carries millions of copies of a DNA strand with three working parts. The first is a cell barcode, which is identical on every strand of that bead and different from every other bead. The second is a unique molecular identifier, or UMI, a short random sequence that differs from strand to strand, and the third is a string of T bases that pairs with the A-rich tail of messenger RNA.

Cells are loaded dilute, so most droplets hold no cell and an occupied droplet ideally holds one cell and one bead. Inside the droplet the cell is broken open and the strands capture its RNA, and reverse transcription then writes the barcode and the UMI into each cDNA molecule. Finally the droplets are broken, and everything is pooled, amplified and sequenced.

23 — Barcoding every cell
IN EACH DROPLET cell bead ONE CAPTURE OLIGO, ENLARGED CELL BARCODE UMI POLY-T which cell this molecule came from AAAAAAAA captured mRNA cDNA copied by reverse transcription now carries barcode + UMI AFTER POOLING droplets broken, everything pooled and sequenced together BC3 BC1 BC5 BC2 BC1 BC4 BC3 sort reads by barcode CELLS (BARCODES) BC1 BC2 BC3 BC4 BC5 gene A 12 0 3 25 1 gene B 0 8 0 2 14 gene C 5 5 19 0 0 gene D 31 2 0 7 4 gene E 0 0 6 1 9 schematic counts UMI: unique tag per captured molecule — PCR copies share it and are counted once
DNARNAReadoutFocal detail
Plate 23 — Single-cell sequencing separates cells only long enough to label them. Each occupied droplet ideally holds one cell and one bead whose DNA barcode is stamped onto every RNA it captures, so after pooling, each read still carries the address of its cell.

Two labels, two jobs

The cell barcode answers the question "which cell did this molecule come from?", and the UMI answers a subtler one: "is this read a new molecule, or a copy of one already counted?" Amplification makes many copies of each captured molecule, and some molecules are copied more than others, so a count of reads would over-count the molecules that amplification happened to copy most. A count of distinct UMIs counts the original molecules instead.

Solved example: how many molecules do 12 reads represent?

For one gene in one cell, 12 reads carry the same cell barcode. Five of them carry the UMI AGT, four carry CCA and three carry TTG, so the 12 reads hold 3 distinct UMIs. The cell therefore yielded 3 captured molecules of this gene's RNA, and the other 9 reads, 12 minus 3, were copies made during amplification, which means a count of reads would have reported four times as many molecules as were captured. The example uses three-letter UMIs for readability. Real UMIs are 10 to 12 bases long, and since each base is one of four letters, a 10-base UMI can be any of about a million sequences and a 12-base UMI any of about 17 million, so two molecules rarely share one by chance.

Only a fraction of each cell's RNA molecules is ever captured and converted, so the data are sparse: most genes read zero in any given cell, even when the cell expresses them at low levels. Single-cell data are therefore powerful for telling cell types and states apart, and weak for measuring small differences in a single low-abundance gene.

Scale, and what it has produced

Throughput has grown by orders of magnitude. In October 2024 the maker of one droplet system stated that the system processes up to 2.5 million cells per run, at a cost as low as one cent per cell. Other methods need no droplets at all: they barcode cells by repeatedly splitting and pooling them in plates, adding one barcode segment per round, and their makers state that one kit can label a million or more cells.

The data from such experiments are gathered in shared resources as well as in the Human Cell Atlas portal. The Chan Zuckerberg Initiative runs one such openly available resource, CELLxGENE Census, and its November 2025 release held about 125 million unique cells from five species, about 100 million of them human, drawn from more than 1,800 datasets. Single datasets have reached the same scale. In a 2025 preprint, the company Tahoe Therapeutics described one dataset that profiled the RNA of 100 million cells from 50 cancer cell lines, each line exposed to about 1,100 combinations of drug and dose. The cells were barcoded by the split-and-pool method in a service laboratory run by one of that method's makers, and 18 of the preprint's 32 authors worked for that maker.

From a matrix to cell types

The output is a matrix of cells by genes that holds UMI counts. Analysis software groups cells with similar expression profiles into clusters, as cytometry software groups cells by their proteins (Chapter 11). It then draws the clusters on two-dimensional maps and labels each cluster by the marker genes it expresses. Cells caught at different stages of a continuous process, such as differentiation, can be ordered into trajectories.

Two artifacts recur. A droplet sometimes captures two cells, and the resulting doublet looks like a hybrid cell type that does not exist. RNA released into the suspension by broken cells is captured in every droplet, so it adds a faint background that all the cells share. Both are handled computationally, and both need to be checked.

Calling a cluster a cell type needs independent evidence

Clusters are statistical groupings whose number and boundaries depend on the analysis settings. A cluster may be a genuine cell type, a transient state, a set of doublets, or cells stressed by the dissociation that freed them from the tissue. Naming a cluster is an interpretation that needs independent evidence, such as known markers, protein measurements or spatial location.

Adding proteins and chromatin

The barcoding logic extends to other layers. For surface proteins, antibodies that carry DNA barcodes instead of fluorescent dyes bind the cell surface before the cell enters the droplet, and their barcodes are then captured and sequenced alongside the RNA. Stoeckius and colleagues described this method, CITE-seq, in 2017: it gives surface protein levels and the transcriptome from the same cell, joining cytometry's view of the cell to sequencing's. Chromatin accessibility can be read cell by cell too, by running the adapter-inserting enzyme of Chapter 6 on nuclei before barcoding, and some kits read RNA and accessibility from the same nucleus.

Putting cells back in place

Dissociating a tissue into single cells throws away where each cell sat, and location matters: a cell's neighbors decide much of what it does, and a pathologist reads disease from the structure of a tissue. Spatial methods keep each measurement's position in the tissue, by two routes that are converging.

Capture arrays place a tissue section on a slide covered with barcoded spots whose positions are known. Each spot captures RNA from the tissue directly above it, and the spot's barcode records where that RNA came from. Capture arrays read the whole transcriptome, and their resolution is set by spot size. Their makers state that some current arrays use features 2 µm wide or smaller, which is smaller than a cell, whereas earlier arrays used spots 55 µm across that pooled several cells.

Imaging methods leave the RNA in place and identify each molecule under a microscope. Panels of probes hybridize to their target RNAs over several rounds, and each gene's pattern of on and off signals across the rounds forms a code that identifies it. The resolution is subcellular and each molecule is placed individually, but only the genes in the designed panel are read. Makers had grown these panels from hundreds of genes to 5,000 or 6,000 by 2024, and in April 2025 one maker described a whole-transcriptome imaging panel that covers more than 18,000 RNAs. Protein imaging works the same way with barcoded antibodies and reaches a hundred or more markers per section.

24 — Keeping the map: two approaches
SEQUENCING-BASED CAPTURE (1,1) (12,8) top view side view tissue section RNA barcoded spots on the slide whole transcriptome · resolution set by spot size (makers' figure: 2 µm or smaller) IMAGING-BASED IN SITU imaging rounds 1 2 3 gene B each molecule decoded to a gene at its exact position subcellular resolution · predefined panel: hundreds to more than 18,000 RNAs (maker, 2025) SPATIAL RESOLUTION GENES MEASURED subcellular spot-sized a chosen panel the trade-off: how many genes vs how precisely placed imaging in situ capture arrays both are converging schematic
DNARNAReadoutFocal detail
Plate 24 — Spatial methods keep the address that single-cell dissociation throws away. Capture arrays read the whole transcriptome at the resolution of their spots; imaging reads a chosen panel molecule by molecule. The two are converging from opposite ends.

Every spatial method must also decide which molecules belong to which cell, a step called segmentation that usually draws cell boundaries from a nuclear or membrane stain. Segmentation errors assign molecules to the wrong neighbor, and in dense tissue they are a leading source of false cell-to-cell signals.

In practice

Most single-cell failures are decided before the instrument runs. Minimize the time and temperature of dissociation, and record both. Measure viability and set an acceptance threshold. Load cells at a density that keeps the doublet rate acceptable. For spatial work, settle the resolution, the gene panel and the tissue area against the biological question first, because gaining on any one of the three costs the other two. Keep a matched section for conventional histology, so that clusters can be checked against the tissue's morphology.

+ What this chapter established
  • Single-cell sequencing labels each cell's molecules with a barcode, then pools them and sorts the reads back into cells.
  • UMIs count original molecules rather than amplification copies, and the data are sparse because only a fraction of each cell's RNA is captured.
  • Clusters are statistical groupings, so calling them cell types needs independent evidence.
  • Spatial methods keep location, either by barcoded capture arrays or by imaging molecules in place.