+ Part VIII · The field in 2026
Who makes the instruments, reagents and tests.
Between 9 February and 17 August 2026, BD's diagnostics business combined with Waters, two investment firms took Hologic private, and Molbio Diagnostics listed its shares on India's stock exchanges. The cyclers, cartridges and reagents of the earlier parts are made and sold by companies like these. This part, one chapter dated October 2026, describes who makes PCR products, layer by layer: open instruments and digital PCR, central-laboratory systems, cartridges, home and point-of-care tests, and reagents, then the makers in India and the businesses that changed hands from 2023 to 2026. It gives each product's record with its regulator where there is one, and it ranks none of them.
The makers, layer by layer.
+ The questionWhich companies make the instruments, cartridges and reagents that PCR runs on in 2026, and what does the regulator's record show for each?
Open instruments, real-time and digital
The CDC's test of February 2020 ran on the Applied Biosystems 7500 Fast Dx, which FDA cleared in 2008 through a 510(k), the US route for a device shown to be substantially equivalent to one already on the market (Chapter 25). Thermo Fisher now sells the Applied Biosystems line. When FDA reissued the CDC's authorization on 15 March 2020, it accepted reagents made by commercial suppliers. One PCR result therefore rests on several makers, of the instrument, the reagents and the test, and each works in a different layer of the field. This chapter takes the layers in turn, as of October 2026. It gives the record of a regulator or public body for each product where one exists, names the source of every other status, and ranks no product.
The first layer holds the open platforms: real-time instruments that run any assay written for them, a kit maker's or a laboratory's own. Thermo Fisher's QuantStudio, Bio-Rad's CFX, Roche's LightCycler and Qiagen's Rotor-Gene Q are the families in this chapter. Several diagnostic versions carry "Dx" or "MDx" in their names, and the older ones hold 510(k)s, from the LightCycler 1.2 in 2003 to the QuantStudio Dx in 2013. The newer QuantStudio 5 Dx, QuantStudio 7 Pro Dx, CFX Opus Dx and CFX96 Dx appear in FDA's listing, the database of the devices that makers sell, with no 510(k) number. As of October 2026, FDA's regulation for this type of instrument exempts it from the 510(k), within limits, and Roche stated in November 2023 that its new LightCycler PRO would be exempt as well.
For the digital PCR of Chapter 14, a search of FDA's 510(k) records by device name finds three tests, and all three monitor one marker, BCR-ABL1, the fusion gene of chronic myeloid leukemia, formed by an exchange between chromosomes 9 and 22. Bio-Rad's QXDx BCR-ABL %IS Kit for its QXDx droplet system was cleared on 13 February 2019, and kits from Suzhou Sniper Medical Technologies and Suzhou Precigenome followed on 5 September 2023 and 2 July 2026. Qiagen stated at the launch of its nanoplate instrument QIAcuityDx in 2024 that the instrument was certified under the IVDR, the EU's regulation for diagnostic devices, and exempt from the 510(k). Under the IVDR a PCR instrument is class A, so its maker declares it conformant itself, without a notified body, the designated assessor that Chapter 26 describes, and the word certified is Qiagen's. Stilla Technologies had announced the end of its naica system, and Bio-Rad, which bought Stilla in 2025, is relaunching Stilla's nio as its own QX700 series. Bio-Rad labels the QX700 E research use only, not for diagnosing patients.
Closed systems, from the central laboratory to the cartridge
Central-laboratory systems automate extraction, PCR and reading for many specimens at once. In FDA's 510(k) records, Roche's cobas 5800, 6800 and 8800 systems hold tests cleared from March 2018 to 8 July 2026, Hologic's Panther Fusion from September 2017 to September 2025, and Abbott's Alinity m from April 2022 to September 2025. BD's molecular systems, BD MAX and BD COR, belong to the diagnostics business that combined with Waters in February 2026, and BD states that it remains their legal manufacturer during the transition.
Cartridges, the sealed disposables of Chapter 18, carry the same chemistry, and some are syndromic panels, which test one specimen for the many pathogens that can cause the same symptoms. Several of Cepheid's Xpert Xpress tests, Roche's cobas liat tests and the BioFire Spotfire panels of bioMérieux were cleared as Dual Track submissions. Each was a 510(k) filed together with an application for a waiver under CLIA, the US law on clinical laboratories, whose least demanding category holds simple tests with a low risk of error (Chapter 25). Cepheid's Dual Track records run from December 2015 to a hemorrhagic fever test of 7 August 2026, the cobas liat's from July 2016, first in the name of IQuum, which Roche acquired, and the Spotfire's from February 2023. Qiagen's QIAstat-Dx panels hold 510(k)s from May 2019 to September 2026 with no Dual Track record: FDA's records list them as traditional 510(k)s, filed without a waiver application.
Home and point of care
Of the three home molecular tests in this chapter, one is PCR. Visby Medical's Women's Sexual Health Test is a single-use device that amplifies DNA by thermocycling from a self-collected swab and reports chlamydia, gonorrhea and trichomoniasis in under 30 minutes. FDA authorized it for over-the-counter home use on 28 March 2025 through the De Novo route, for a new kind of device with nothing equivalent on the market. Visby calls it the first PCR device approved by FDA for home use for any indication, though FDA's record shows the De Novo request granted, and FDA calls the result a marketing authorization, not an approval (Chapter 25). Visby's newest clearance, for an influenza and COVID-19 test, came on 27 May 2026.
The other two copied their targets at one temperature (Chapter 23). Cue Health's 20-minute COVID-19 test received a De Novo authorization for over-the-counter use on 6 June 2023. Cue's bankruptcy filing was reported on 29 May 2024, and FDA revoked Cue's two emergency authorizations, effective 9 October 2024, after Cue said it had stopped making the test. Lucira Health, whose tests used LAMP, filed for bankruptcy on 22 February 2023, and Pfizer bought its assets in April 2023 and later ended the business, citing the cost of the tests. FDA revoked both Lucira by Pfizer authorizations, effective 22 October 2025, because no viable reagents remained in the United States. Both isothermal home tests have left the market, and at the point of care Abbott's ID NOW, the test of Chapters 18 and 23, is isothermal too.
A name or a press release can say "molecular" without saying whether the test cycles. The authorization documents say which: "thermocycling" for Visby's test, "isothermal nucleic acid amplification technology" for Cue's test and for ID NOW. A comparison of PCR products that counts isothermal tests sets two chemistries side by side, with the different failure modes of Chapter 23.
Reagents and oligos
Every layer depends on the makers of polymerases, master mixes and oligonucleotides, or oligos: the short synthetic strands of DNA that serve as primers and probes. Integrated DNA Technologies, IDT, makes oligos as an operating company in Danaher's life sciences segment, and Danaher's diagnostics segment holds Cepheid, so one owner holds both an oligo maker and a cartridge maker. Roche sells assays through its subsidiary TIB Molbiol, and by Roche's count of November 2023 more than 60 of them carried the CE mark for diagnostic use in the EU. New England Biolabs states that it manufactures in a facility in Ipswich, Massachusetts, certified to ISO 13485:2016, the medical device quality standard that FDA's quality regulation now incorporates (Chapter 25). Takara Bio states that it offers manufacturing to good manufacturing practice in Japan, and its US site marks its products for research use only. Chapter 22 showed the limit of what a supplier controls: the CDC's N3 flaw appeared in oligos from all three of the CDC's sources.
India
Molbio Diagnostics makes Truenat, a portable, battery-operated system whose Truelab analyzer runs real-time PCR on a chip and gives results in under an hour. On 2 July 2020 the Indian Council of Medical Research, ICMR, and Molbio announced that WHO had endorsed three Truenat assays for the initial diagnosis of tuberculosis and for detecting resistance to the drug rifampicin, after an ICMR validation found them comparable to Cepheid's Xpert MTB/RIF. Such an endorsement is a WHO recommendation that a type of test may be used for a purpose. Prequalification is WHO's separate assessment of a named product, and as of October 2026 WHO lists Truenat MTB Plus as under assessment for it.
During the pandemic, ICMR had most commercial RT-PCR kits evaluated at centers it designated before India's central regulator, the Central Drugs Standard Control Organisation, CDSCO, approved them (Chapter 26). Its summary of 17 February 2022 counted 523 kits evaluated and listed 211 as satisfactory, each only for the batch numbers given. The Indian makers on the list include Mylab, Huwel, Genes2Me, Meril, CoSara and Trivitron, and Truenat is not on it.
ICMR's summary gives 523 kits evaluated and 211 listed as satisfactory. The share is 211 ÷ 523 = 0.403, or about 40 %. The remaining 523 − 211 = 312 kits, about 60 %, are not on the list. The count is of evaluations at ICMR's centers, not of CDSCO approvals. In words: of the RT-PCR kits put through ICMR's evaluation by February 2022, fewer than half were listed as satisfactory.
Two of the listed makers were each described as first in March 2020. The US company Co-Diagnostics stated on 19 March that its joint venture CoSara was the first Indian company licensed by CDSCO to manufacture RT-PCR kits for COVID-19, and on 24 March a trade report carried Mylab's claim that its kit was the first to receive commercial approval. The claims may describe different steps, a license to manufacture and an approval to sell. In February 2026 Co-Diagnostics announced that CoSara had received a license on Form MD-5 to manufacture its CoSara PCR Pro, a point-of-care real-time PCR instrument, in Gujarat. CDSCO's list puts a PCR analyzer in class A, the lowest of India's four risk classes, and for class A a state licensing authority issues the MD-5 license (Chapter 26). The instrument's kits for tuberculosis and for human papillomavirus still needed their own clearance.
Changes of hands, 2023–2026
On 6 June 2024 Qiagen announced that it would discontinue its NeuMoDx integrated PCR systems, citing the market after the pandemic, with a restructuring charge it put at about $400 million. On 29 July 2024 Roche completed its purchase of LumiraDx's point-of-care technology, an immunoassay and clinical chemistry platform that is not PCR. Bio-Rad gives 30 June 2025 as the date it finalized its purchase of Stilla Technologies, and trade reports of the completion followed on 7 and 8 July. BD's Biosciences and Diagnostic Solutions businesses were spun off and combined with Waters on 9 February 2026. Blackstone and TPG completed their purchase of Hologic on 7 April 2026, taking it private, and Molbio listed its shares in India on 17 August 2026.
New tests kept arriving: FDA cleared at least eight PCR tests from Roche, Visby, Suzhou Precigenome, Cepheid and Qiagen between 15 May and 24 September 2026. The words in these records, cleared, listed, authorized, waived, licensed and endorsed, name different acts, and Chapters 25 and 26 describe the systems behind them.
Before choosing an instrument, a cartridge platform or a reagent supplier, look up its status in the record of every market it will serve, check whether it is labeled for research use or for diagnosis, and treat a status that only the company states as a claim to verify. Then plan for the supplier changing: four product lines in this chapter had ended by 2026 and five businesses changed hands between 2023 and 2026, so a design that depends on one maker needs a second qualified source or a plan for its withdrawal.
- The newer diagnostic open instruments are listed with FDA without 510(k)s, and the three digital PCR tests found in FDA's 510(k) records all monitor BCR-ABL1.
- Cartridge tests divide in FDA's records between Dual Track clearances, with a CLIA waiver application, and 510(k)s filed without one, which FDA's records call traditional.
- Of the three home molecular tests in this chapter only Visby's is PCR, and both isothermal ones have left the market.
- India's records come from ICMR, WHO and makers' statements of CDSCO licenses, and four product lines in this chapter had ended by 2026 and five businesses changed hands from 2023 to 2026.