One stretch out of billions.
+ The questionHow do two short primers pick out one target from billions of DNA letters, and what makes them pick the wrong one?
How rare is a twenty-letter word?
A primer twenty bases long is a word of twenty letters written in an alphabet of four. There are 4²⁰ such words, about 1.1 × 10¹². A human genome has about 3.05 billion base pairs, and read along both strands it offers about 6.1 × 10⁹ places where a twenty-letter word could sit. If genomes were random strings of letters, the expected number of chance matches to any given twenty-letter primer would be about 6.1 × 10⁹ divided by 1.1 × 10¹², or about 0.006. On this arithmetic, a primer designed for a viral sequence would be very unlikely to find a perfect match anywhere in human DNA.
That arithmetic explains why primers work at all, and it also overstates how selective a primer is, for three reasons. First, real genomes are not random. They contain repeated sequences, and some, such as the Alu elements, are present in about a million copies, so a primer that happens to resemble one of them has many places to bind. Second, at a low enough temperature a primer does not need a perfect match to bind: a near-match with one or two mismatches can hold, especially if the mismatches are far from the end the polymerase extends. Third, the sample contains more than human DNA. So the specificity of PCR does not rest on any single primer being unique. It rests on the primers working as a pair, on the annealing temperature, and on the way the polymerase treats the end of a primer.
The pair is what selects
The polymerase extends only from a primer, and only in one direction (Chapter 3). PCR uses two primers designed to bind to opposite strands, at the two ends of the target, each pointing toward the other. When each primer is extended, it produces a new strand that runs across the target and through the binding site of the other primer.
The geometry of the pair is the real filter. A primer that binds by chance at an unrelated site produces a single extended strand. That strand is copied exponentially only if the second primer also binds to it, on the opposite strand and facing back, within the distance the polymerase can cover in one extension step. It is far less likely that both primers find mismatched sites arranged like that, close enough together, than that either finds one alone. A stray binding event usually produces a few strands that grow by one per cycle and never become visible. The true target lies between both primers, so it grows exponentially and soon far outnumbers those strands.
Where the defined product first appears
The geometry also explains a detail that surprises most people when they first follow the cycles one by one. In the first cycle, each primer is extended along a long original strand, and the polymerase simply keeps going past the far end of the target until the step ends. The new strand has one defined end, where the primer started, and one ragged end. Strands of this kind are called long products. In the second cycle, the other primer binds to one of those long products and is extended toward its defined end. Because that template strand ends exactly where the first primer began, the copy stops there, and the result is the first strand of exactly the target's length. In the third cycle, two such exact strands pair into the first double-stranded product with both ends defined by the primers.
From then on, the exact-length product doubles every cycle, while the long products increase by only two per cycle from each original duplex, because only the original strands make them.
The reaction starts from one double-stranded target, at 100 % efficiency. After n cycles it holds 2ⁿ duplexes in all, and 2n of them still contain an original strand or a long product, so 2ⁿ − 2n are of exact length. For cycles 1 to 7 that gives 0, 0, 2, 8, 22, 52 and 114. After 30 cycles it gives 2³⁰ − 60, or about 1.07 × 10⁹ exact-length duplexes, beside just 60 long products. By the time anything is detectable, essentially all of the product is the stretch between the two primers.
Mispriming, primer-dimers and the hot start
Two kinds of wrong product are common, and both start when the temperature is too low for the primers to bind selectively.
The first is mispriming: a primer binds to a site that only partly matches, and the polymerase extends it. Whether that matters depends on which end of the primer the mismatch is near. The polymerase extends only from a 3′ end that is paired to the template, so a mismatch at or very near the 3′ end greatly reduces extension, while a mismatch near the other end of the primer is often tolerated. Primer designers use this deliberately, placing the most discriminating bases near the 3′ end.
The second is the primer-dimer, which forms between the two primers. They are present at enormous concentration, and they bind briefly to each other through a few complementary bases at their 3′ ends. The polymerase then extends both across each other. The result is a short double-stranded product that contains both primer sequences, so it amplifies as efficiently as a real target. It competes with the target for the reaction's resources, and with some detection chemistries it produces signal of its own.
Both errors are most likely before cycling starts. When a reaction is assembled at room temperature, the primers bind loosely to anything partly complementary, and a polymerase that keeps a little activity at room temperature extends those mistakes. In a study published in 1992, scientists at Cetus, the company where PCR was invented, prevented any activity before the first heating step, using a layer of wax that kept the reagents apart until it melted. They found large improvements for targets below about a thousand copies, enough to amplify a single target molecule of HIV in a background of human DNA.
Any method that prevents polymerase activity until the first heating step is called a hot start, and hot-start methods now do the same job in other ways. In one, an antibody binds and blocks the polymerase until heat destroys the antibody, in another a chemical modification of the enzyme is reversed by a long initial heat step, and in a third a short DNA molecule binds the enzyme and lets go when heated. With TaqPath, one of the commercial master mixes named in the CDC test's instructions, the two-minute hold at 95 °C at the start of the test's cycling serves this purpose.
The arithmetic of twenty-letter words shows that a perfect chance match in a genome is unlikely. It does not show that a primer will bind only where intended. Repeated sequences, near-matches at low temperature, primer–primer pairing and activity during set-up all produce wrong products. Specificity is designed through the pair geometry, the annealing temperature, hot start and checks of the sequences, and it is then demonstrated by testing.
Designing for the right target
The design rules that follow from all this are conventions rather than laws, and suppliers state them a little differently. Primers are usually 18 to 30 bases long, with 40 to 60 % G and C and a G or C at the 3′ end to anchor it. The two primers' melting temperatures are kept within about 5 °C of each other, so that one annealing temperature suits both. Runs of four or more identical bases are avoided, and so are sequences that can fold on themselves or pair with the other primer.
For diagnostic tests the target itself is chosen with care. A good target region is conserved across all known variants of the organism, so that no strain escapes detection, and it is absent from the organism's relatives and from human DNA, so that nothing else is detected. Most of these checks are done by computer before any reagent is made. The designer aligns the primers against every available sequence of the target organism to check that all are matched, and against the sequences of related organisms and human DNA to check that none is. During the COVID-19 pandemic, the FDA asked developers to show by such alignments that their primers matched all published SARS-CoV-2 sequences, and to treat any similarity above 80 % between a primer and another organism as a possible cross-reaction to be tested in the laboratory. The agency made both requests in its template for developers seeking emergency authorization.
A test with a probe has at least three oligonucleotides, short strands of DNA made to order, in the same tube. A multiplex test detects several targets in one reaction, so it has many more. Each pair must be checked for complementarity, especially at the 3′ ends, because any two that can pair and be extended can make a product in any reaction, including those with no target. The oligonucleotides for the CDC's original third target, N3, had exactly this flaw: the 3′ end of the probe could pair with the 3′ end of the reverse primer, one of the two primers of the N3 reaction. A no-template control is a reaction with every reagent but no sample, so it should show no amplification. With the reagents of the first authorized kits, false signal appeared in about 97 % of N3 no-template controls, against 0.5 to 2 % for the same sequences from other sources, and it grew more frequent as the reagents aged (Chapter 22).
- A twenty-base primer is unlikely to match a random genome by chance, but repeats, near-matches and primer–primer pairing make chance alone an inadequate defense.
- Two primers on opposite strands, facing each other, are the real filter: only the stretch between them is copied exponentially.
- Exact-length duplexes first appear in cycle 3 and then double each cycle, and after 30 cycles they outnumber the long products by tens of millions to one.
- Mispriming and primer-dimers arise mostly at low temperature and before cycling, and hot start, 3′-end design and computer checks of every oligonucleotide control them.
Let's Talk