07 — The heat-stable enzyme

An enzyme that survives the heat.

+ The questionWhy couldn't PCR be automated until it used an enzyme from a hot-spring bacterium?

The Klenow years

The first PCR experiments used a fragment of DNA polymerase from the bacterium E. coli, called the Klenow fragment. It copied DNA well at moderate temperatures, but it was destroyed by the first heating to separate the strands. So in the first published application of PCR, in 1985, the tube was opened after every denaturation and fresh enzyme was added by hand, twenty times in a twenty-cycle run (Chapter 3). Extension ran at 30 °C, the temperature the enzyme tolerated, and annealing at the same low temperature.

Both features limited the method. Adding enzyme every cycle was laborious and opened the tube twenty times to contamination. And annealing at 30 °C let primers bind to partial matches all over the sample, so the reaction made many products besides the target. The first experiments compensated by detecting the product with a labeled probe, which picked the right product out of the mixture. Cetus engineers built automated prototypes to do the pipetting, and one of them was nicknamed "Mr. Cycle", after a coffee machine. But the real solution was an enzyme that did not need replacing.

14 — Before and after Taq
1985: KLENOW FRAGMENT 95 °C 30 °C open the tube, add fresh enzyme 20 cycles: enzyme added by hand 20 times 30 °C: primers bind partial matches the target products of partial matches 1988: TAQ POLYMERASE 95 °C 30 °C anneal and extend: hot added once: the run could be automated enzyme added once; tube stays sealed; a programmable heater runs the program annealing and extension run hot: primers bind only good matches the target products up to about 2,000 bases; single-copy genes amplified more than ten-million-fold Perkin-Elmer Cetus thermal cycler on sale: 1987
CopiesHeatFocal detail
Plate 14 — With an enzyme destroyed at 95 °C, every cycle meant opening the tube and adding fresh enzyme, and annealing at 30 °C let primers bind loosely all over the sample. Taq survives denaturation, so it is added once, the tube stays sealed, a programmable heater can run the whole program, and annealing and extension run hot, where primers bind only good matches.

A bacterium from Yellowstone

That enzyme came from a microbe isolated twenty years earlier for an unrelated reason. In 1966 the microbiologist Thomas Brock and his undergraduate student Hudson Freeze took samples from microbial mats in Mushroom Spring, in the Lower Geyser Basin of Yellowstone National Park, and the water where they sampled was about 71.5 °C. From one sample they grew a bacterium that thrived in heat, and in 1969 they described it as a new species, Thermus aquaticus. It grows between about 40 and 79 °C, best at about 70 °C.

An organism that lives at 70 °C needs proteins that work at 70 °C. In 1976 the DNA polymerase of T. aquaticus was purified and found to be most active near 80 °C. In 1988 scientists at Cetus, the company where PCR was invented, published PCR with this enzyme, now called Taq polymerase, in place of the Klenow fragment.

Because Taq survived the denaturing step, it could be added once at the start, the tube could stay sealed, and the entire run could be automated with a programmable heater. Because it worked at high temperature, annealing and extension could be done hot, where primers bind only to good matches. The group reported higher specificity and yield, products up to about 2,000 bases long, and amplification of single-copy human genes more than ten-million-fold. A commercial thermal cycler from Perkin-Elmer Cetus had reached the market in 1987, and PCR spread through laboratories within a few years.

Taq's bacterium lives in hot water well below boiling

Taq is often said to come from microbes living in near-boiling water and to work best at 72 °C. T. aquaticus was isolated from water at about 71.5 °C and grows up to about 79 °C. Its polymerase is most active at 75 to 80 °C (Chapter 4). The enzyme's tolerance of 95 °C is enough to survive brief denaturing steps, not indefinite boiling.

Heat stability has a half-life

Taq is thermostable, not indestructible. In 1993 scientists at Roche Molecular Systems, which made the enzyme, published a characterization of the purified enzyme. They measured how long the enzyme kept half its activity at denaturing temperatures: about 45 to 50 minutes at 95 °C, but only 9 minutes at 97.5 °C. Two and a half degrees cut its half-life by a factor of five.

15 — Enzyme life at temperature
0 % 25 % 50 % 75 % 100 % 0 15 30 45 60 TAQ ACTIVITY REMAINING MINUTES HELD AT TEMPERATURE a classic run: 30 cycles × 30 s 95 °C: half-life 45–50 min 97.5 °C: half-life 9 min CDC test: about 4.3 min hot, 94 % left 79 % 2.5 degrees hotter: 31 % left, not 79 % 1993 characterization of purified Taq
HeatFocal detail
Plate 15 — Taq keeps half its activity for about 45 to 50 minutes at 95 °C but only 9 minutes at 97.5 °C. Fifteen minutes at 95 °C leave about 79 % of the enzyme; the same time at 97.5 °C leaves about 31 %. The CDC test's short steps, about 4.3 minutes hot in all, leave about 94 %.
Solved example: how much enzyme survives a run

With a half-life of 45 minutes at 95 °C, Taq's activity halves for every 45 minutes spent there. A classic run of 30 cycles holds 95 °C for 30 seconds in each cycle, which makes 15 minutes hot, or a third of a half-life. A third of a halving leaves 0.5 raised to the power one third, or about 79 % of the activity. At 97.5 °C the half-life is 9 minutes, so the same 15 minutes are 1.7 half-lives and leave about 31 %. The CDC test's program holds 95 °C for 2 minutes at the start and for 3 seconds in each of 45 cycles, about 4.3 minutes in all, and about 94 % of the activity remains. Short denaturing steps spare the enzyme, and they need an instrument that brings the liquid to temperature quickly.

The arithmetic makes concrete a point from Chapter 2: the denaturing temperature is a compromise between opening every target duplex and preserving the enzyme. If an instrument lets the liquid in its wells overshoot 95 °C by a couple of degrees, for a few seconds every cycle, it consumes enzyme life that the assay was not designed to spend, while one whose wells fall short risks leaving strands unseparated. The block itself is often driven past the set point on purpose, but what matters is the temperature of the liquid (Chapter 10). Both errors are invisible unless someone measures them.

No proofreading, and a useful side activity

Cells copy DNA with proofreading polymerases that check each base and remove mistakes. Taq has no such proofreading activity, so it makes more errors. How many depends on how errors are measured, and different methods give results more than tenfold apart for the same enzyme, so comparisons are only meaningful within one study. In 2017 scientists at a company that sells high-fidelity enzymes counted errors by sequencing single molecules, and for Taq they measured about 150 errors per million bases per doubling, against about 5 for the proofreading enzyme Pfu and 0.53 for the company's own engineered enzyme, Q5.

For detection, Taq's error rate hardly matters. For a 100-base target copied through 30 doublings, the average number of errors per final molecule is about 100 × 30 × 150 per million, or about 0.45. But the errors fall at random positions in different molecules, so the population as a whole still carries the correct sequence, and a probe or a primer binds regardless of an occasional changed base elsewhere. When one molecule is picked out of the mixture, to be cloned or to define a sequence, the errors matter, and a proofreading enzyme is used.

Taq has one more activity that turned out to be valuable. As it extends a strand, it degrades any short piece of DNA bound to the template in its path, an activity called 5′ to 3′ exonuclease. In 1991 Taq's developers at Cetus showed that this activity could be used to cut a labeled probe sitting inside the target, generating a signal as the target is copied. Chapter 12 shows how probe cleavage became the most common detection chemistry in diagnostic PCR.

The enzyme is a system decision

Choosing a polymerase sets several parameters of the whole test at once, starting with the length of the initial activation step: one supplier states that a chemically blocked enzyme may need up to about 10 minutes at 95 °C, and an antibody-blocked one about a minute. The choice also sets the extension rate and therefore the shortest workable cycle, the fidelity of the copy, and whether probe cleavage is available as a detection method. Each choice reaches the instrument as a temperature profile it must deliver.

+ What this chapter established
  • Early PCR used an enzyme destroyed at 95 °C, so fresh enzyme was added by hand every cycle and annealing ran at a non-selective 30 °C.
  • Taq polymerase comes from a bacterium isolated in a Yellowstone spring at about 71.5 °C, and because the enzyme survives denaturation it could be added once, which made sealed, automated, high-temperature PCR possible.
  • Taq's half-life is about 45 to 50 minutes at 95 °C and 9 minutes at 97.5 °C, so short denaturing steps and accurate temperatures preserve it.
  • Taq lacks proofreading, which matters for cloning but not for detection, and its 5′ to 3′ exonuclease activity became the basis of probe detection.
Created with Claude (Anthropic).
Educational reference material, not engineering, regulatory or clinical advice. Product and company names referenced are the property of their respective owners.