What heat can do to DNA.
+ The questionWhat is it about DNA's structure that lets heat pull the two strands apart without breaking either one?
Two kinds of bond
DNA is two long chains wound around each other. Each chain, or strand, is a backbone of sugar and phosphate groups joined end to end by covalent bonds, and from every sugar a base sticks out sideways: adenine, thymine, guanine or cytosine, the A, T, G and C of the genetic code. The sequence of bases along one strand is the information. The two strands run in opposite directions, and they face each other base to base, so that the double helix looks like a ladder whose rungs are pairs of bases. A two-stranded molecule of this kind is called a duplex.
The two kinds of connection in this structure differ enormously in strength, and PCR depends on that difference. Along each strand, the links between one sugar and the next phosphate are covalent bonds, shared electrons that need a chemical reaction to break. Between the strands there are no covalent bonds at all. The strands are held together by many weak interactions, each of which ordinary thermal motion can disrupt.
Two of those weak interactions matter. The first is base pairing: A sits opposite T, held by two hydrogen bonds, and G sits opposite C, held by three. The shapes and hydrogen-bonding patterns of the bases fit only in these combinations, which is why one strand determines the sequence of the other. The second is stacking: the flat bases lie on top of one another along the helix like a pile of coins, and the attraction between neighboring pairs in the stack is what holds the duplex together most firmly.
A common account says that hydrogen bonds hold the two strands together, and that DNA rich in G and C separates into single strands, or melts, at a higher temperature because a G–C pair has three hydrogen bonds instead of two. When the two contributions were measured separately, the result was different. Stacking between neighboring base pairs provides most of the duplex's stability and nearly all of its dependence on temperature and salt. Base pairing itself contributes little, and for an A–T pair it is slightly destabilizing. About half of the extra stability of G–C-rich DNA comes from stacking. The useful division is this: hydrogen bonding decides which base pairs with which, and stacking decides how firmly the paired strands stay together.
Melting
Heat is random molecular motion. As a DNA solution is warmed, the motion grows until it overwhelms the weak forces between the strands. The covalent backbone is far stronger and stays untouched, so the duplex comes apart into two intact single strands. This separation is called melting or denaturation, though nothing turns from solid to liquid. The temperature at which half the DNA is single-stranded, the midpoint of melting, is the melting temperature, written Tm.
Melting is not gradual across all temperatures. Because each base pair's stability depends on its neighbors in the stack, a region that starts to open makes the next region easier to open, and long DNA comes apart over a narrow range of a few degrees. The Tm itself depends on composition and on the solution. A classic study measured long genomic DNA in a fairly salty buffer, 0.2 molar sodium, and found that the Tm rises in a straight line with G–C content: about 69.3 °C plus 0.41 °C for every percentage point of G and C.
For long DNA in 0.2 molar sodium, the melting temperature is about 69.3 °C plus 0.41 °C for every percentage point of G and C. For DNA with 40 % G and C, the increase is 0.41 × 40 = 16.4 °C, so its melting temperature is 69.3 + 16.4, or about 85.7 °C. For DNA with 60 % G and C, the increase is 0.41 × 60 = 24.6 °C, so its melting temperature is 69.3 + 24.6, or about 93.9 °C. In the buffer of a PCR the salt is lower and magnesium is present, so the exact values differ. The lesson holds all the same: almost all natural DNA is fully single-stranded a few degrees above 90 °C, and a very G–C-rich target may need 98 °C.
The solution matters as much as the sequence. The two backbones carry negative charges that repel each other, and positive ions in the solution shield those charges, so more salt means a more stable duplex and a higher Tm. Raising sodium from the tens of millimolar to one molar can shift the Tm of a short DNA strand by as much as 20 °C, and magnesium, which every PCR contains, has an even larger effect per unit of concentration. The concentration of the strands themselves also moves the Tm of short pieces of DNA by several degrees. A melting temperature is therefore a property of a sequence in a particular solution, not of the sequence alone.
These melting temperatures are why PCR denatures at 94 to 98 °C. The temperature is chosen to be safely above the Tm of the target in the reaction buffer, so that every duplex opens in a few seconds. It is also kept low enough for the polymerase in the tube to survive as long as possible, and Chapter 7 quantifies that balance.
Cooling puts the strands back
Melting is reversible. When the solution cools, single strands collide. Two stretches of DNA are complementary when each base in one can pair with the base opposite it in the other, A with T and G with C. When two complementary strands meet, the base pairs form, the stack reassembles and a duplex reappears. This re-pairing is called annealing or renaturation, and its speed depends on how often the right partners meet, which depends on their concentration.
PCR uses annealing deliberately. When the reaction cools after denaturation, two kinds of pairing compete. The long original strands can find each other again, or the primers can find their matching sites on the single strands. The primers are the short designed pieces of DNA of Chapter 1, and they are added in vast excess. Chapter 3 shows that the primers outnumber the template strands by about two hundred million to one, so the primers almost always win.
Temperature also decides how perfect a match must be. A duplex with a mismatched base pair in it is less stable than a perfect one and melts at a lower temperature. At a carefully chosen annealing temperature, a primer that matches its target perfectly stays bound, while one bound to a near-match comes apart from it. The strictness that the annealing temperature imposes on a match is called stringency, and it is the first of PCR's defenses against copying the wrong sequence. Chapter 5 shows how it is used.
What heat costs
The backbone survives 95 °C, but heat still damages DNA chemically, though slowly. The most common change converts cytosine into uracil, which the polymerase then reads as thymine. Two scientists at New England Biolabs, a polymerase supplier, measured this damage in a single-molecule sequencing study and found about 1.4 changes per million bases per cycle. A 100-base target copied over 40 cycles offers 4,000 chances for that damage, one for each base in each cycle, so it carries about 0.006 changes on average, and fewer than one molecule in a hundred carries a heat-induced change. That damage is irrelevant to detecting a virus, but it matters to anyone using PCR to prepare DNA for sequencing.
The larger cost falls on the polymerase. Every second spent at denaturing temperatures shortens its working life, and the loss accelerates sharply above 95 °C. This loss is the reason the top temperature of the cycle is not simply set as high as possible, and it is also why an instrument that overshoots its set point is not harmless.
An assay sets its denaturing temperature as a compromise between opening every target duplex and preserving the enzyme. An instrument that runs a degree cold at the top risks incomplete denaturation and late or absent amplification. One that runs hot shortens the enzyme's working life. Chapter 10 shows that both errors occur in real instruments and how they are measured.
- Each DNA strand has a covalent backbone, and the two strands are held together only by weak interactions, mainly base stacking, while hydrogen bonding decides which bases pair.
- Heat separates the strands without breaking them, the melting temperature depends on G–C content, salt, magnesium and strand concentration, and almost all natural DNA is single-stranded a few degrees above 90 °C.
- Cooling lets complementary strands pair again, and because mismatched pairs are less stable, the annealing temperature sets how exact a match must be.
- Heat has costs: slow chemical damage to DNA and, more important, loss of enzyme activity, which grows quickly above 95 °C.
Let's Talk