+ Part IV · Counting

From copies to a number.

In 1993 Russell Higuchi and colleagues at Roche used a video camera to watch many reactions at once, cycle by cycle, and saw that the fewer cycles a reaction needed to reach detectable fluorescence, the more target it had started with. Copying answers whether a target is there, but the central question also asks how much. This part keeps the chemistry fixed and changes only when and how the product is read: once at the end, in every cycle, or one partition at a time. It shows how light reports the copies, how the cycle at which the light crosses a line becomes a quantity, what that number can and cannot be trusted for, and how splitting a sample into thousands of partitions counts molecules directly. By the end of this part the central question is answered.

11 — Three generations

Endpoint, real-time and digital.

+ The questionOnce PCR could copy, what did each generation add to answering "how much"?

One chemistry, three ways to read it

The cycle described in Part II has not changed in its essentials since Taq polymerase made it automatic in 1988: denature, anneal, extend, repeat. What has changed is when and how the product is observed, and with it the questions PCR can answer. The history is best told by holding the chemistry constant and asking, for each generation, what it reads, when it reads it, and therefore what question it can answer. Each answers a sharper question than the last.

Endpoint: is it there, and is it the right size?

The first generation ran the reaction to completion and then looked at the product, which is why it is called endpoint PCR. The standard way to look was gel electrophoresis. DNA's backbone carries a negative charge on every phosphate group, so in an electric field DNA moves toward the positive electrode. The gel is a slab of agarose, a seaweed polysaccharide that forms a mesh of pores, and short pieces of DNA move through the mesh faster than long ones. After half an hour or so, the products of each reaction have spread out by size. A lane of DNA fragments of known lengths, run alongside, acts as a ruler, and a fluorescent stain makes the DNA visible under ultraviolet or blue light.

24 — Reading a gel
LADDER SAMPLE 1 SAMPLE 2 SAMPLE 3 CONTROL POSITIVE TEMPLATE NO expected size known lengths primer-dimer DNA moves toward +: longer pieces slower an ethidium-stained band needs about 0.5–5 ng of DNA: visible only near the plateau empty: below the limit, or failed? the positive control decides
CopiesFocal detail
Plate 24 — DNA's negative backbone pulls it toward the positive electrode, and the gel's mesh lets short pieces move faster, so products spread out by size beside a ladder of known lengths. A band at the expected size says the primers found their target. A stained band needs about half a nanogram to five nanograms, so it appears only near the plateau, and an empty lane means nothing without a positive control.

A band at the expected position says that the reaction made a product of the expected size, which is good evidence that the primers found their target. According to a stain supplier, a band stained with ethidium bromide needs roughly half a nanogram to five nanograms of DNA, which for a 200-base-pair product is roughly 2 billion to 20 billion copies (Chapter 1). More sensitive stains need less, but a band still becomes visible only well into the reaction, near or at the plateau. The endpoint therefore answers the question "is it there?" well and the question "how much?" badly, because reactions started from very different amounts end at similar plateaus (Chapter 8).

Endpoint detection has two other weaknesses. An empty lane can mean that the target was below the limit or that the reaction failed, and a positive control run alongside can tell the two apart only for the run as a whole (Chapter 8). It shows that the reagents and the instrument worked, but a failure in one sample's own reaction, from a substance in the specimen that slows the enzyme, for example, shows only in a control amplified from that same sample (Chapter 21). Opening the tube after amplification also releases billions of copies of product into the laboratory, where a trace can reach the next reaction and give a false positive. Chapter 20 describes the chemical defense against such carry-over.

Real-time: how much, compared with known amounts?

The second generation kept the tube closed and watched the reaction as it ran. Russell Higuchi and his colleagues worked in the PCR group that passed from Cetus to Roche in 1991. In 1992 they added ethidium bromide to the PCR itself. This dye fluoresces much more strongly when it is bound to double-stranded DNA, and they followed its fluorescence through the wall of the tube as the product accumulated. In 1993 they used a video camera to watch many reactions at once, cycle by cycle, and observed the relationship that real-time PCR has used ever since: the fewer cycles a reaction needs to reach detectable fluorescence, the more target it started with.

Reading in every cycle changes what can be measured. At the plateau, reactions that started from different amounts look alike, but in the exponential phase they stay apart: a tenfold difference in starting target appears as a steady gap of about 3.3 cycles (Chapter 6). The instrument records the cycle at which each reaction's fluorescence crosses a fixed line. Recording that cycle turns the gap into a number, and samples of known amount, run alongside, allow the number to be converted into a quantity. Real-time PCR answers "how much, relative to known standards?" In 1996 researchers at Genentech and at the Applied Biosystems division of Perkin-Elmer, which made the instrument they used, described real-time PCR with fluorescent probes. They reported a working range of at least five tenfold steps, or 100,000-fold, with no handling of the product after amplification. Chapters 12 and 13 show how the light is produced and how the number is read.

Solved example: what a gel and a real-time read report for a thousandfold difference

Two reactions, chosen for illustration, start with 1,000 and 1,000,000 copies of the target, and both are assumed to amplify with the same, near-perfect efficiency. The second holds 1,000 times as much, which is three tenfold steps, because 10 × 10 × 10 = 1,000. At about 3.32 cycles per tenfold step, its curve crosses the line about 3 × 3.32 ≈ 10 cycles earlier, so the real-time read reports the difference as a gap of about 10 cycles. By the last cycle both reactions have reached similar plateaus, so their bands on a gel look alike, and the gel reports only that a product of the right size is present in both. Across the working range reported in 1996, at least 100,000-fold, a difference in starting amount shows as a difference in crossing cycle.

Digital: exactly how many molecules?

The third generation abandoned the curve altogether. A sample can be diluted and split into many separate reactions, or partitions, so small that most contain one target molecule or none. Each little reaction then either amplifies or does not, and counting the reactions that light up counts the molecules. In a 1992 study, researchers used this limiting-dilution principle, with statistics, to count the targets of a leukemic cell clone, and they detected about two such targets among 160,000 normal genomes. In 1999 Bert Vogelstein and Kenneth Kinzler named the approach digital PCR. They described it as turning the exponential, analog output of PCR into a linear, digital count, and they used it to detect a cancer-causing mutation in DNA shed into the stool of patients with colorectal cancer.

25 — Three ways to read one chemistry
same primers, polymerase and cycle in all three ENDPOINT REAL-TIME 1992–93 DIGITAL, NAMED 1999 in out the exponential phase remembers the start reads once, after the last cycle Is it there, and is it the right size? reads every cycle How much, compared with known amounts? counts the bright partitions Exactly how many molecules?
CopiesHeatReadoutFocal detail
Plate 25 — The chemistry is the same in all three; what changes is when the product is read and into how many reactions the sample is divided. Endpoint reads once on a gel and answers whether the target is there; real-time reads every cycle in a closed tube and answers how much, against standards; digital counts positive partitions and answers exactly how many molecules.

Digital PCR answers "exactly how many target molecules were in this volume?" without a curve and without standards of known amount. It does depend on knowing the volume of each partition, and on a statistical correction for partitions that receive more than one molecule (Chapter 14).

All three generations remain in use

Each generation matches a different need. An endpoint reaction with a gel is still the cheapest way to check that a product has the expected size, and endpoint PCR prepares DNA for sequencing and cloning. Real-time PCR is the form of PCR most used in diagnostics, because it is closed, fast and quantitative enough. Digital PCR is used where an absolute count or a very rare target matters, such as a tumor mutation present in a small fraction of the DNA in a blood sample.

The evolution at a glance

GenerationWhen it readsWhat it readsThe question it answers
Endpointonce, after the last cycleproduct size and presence, on a gelIs it there, and is it the right size?
Real-timein every cyclefluorescence rising with the productHow much, compared with known amounts?
Digitalonce, after cycling, partition by partitionthe number of positive partitionsExactly how many molecules?

The chemistry in all three is the same primers, polymerase and cycle. What changed is when the light is read and how many separate reactions the sample is divided into.

Choose the generation by the question

For a test developer, the first design question is which of the three questions the result must answer. A yes-or-no infectious-disease test needs a reliable call at a cut-off, which real-time PCR provides. A viral-load test needs a quantity, with standards and an efficiency that holds across the range. A test for a rare mutation needs to count a few mutant molecules among many normal ones, which is where partitioning justifies its cost.

+ What this chapter established
  • The chemistry has stayed the same, and the generations differ in when and how the product is read.
  • Endpoint PCR reads the product on a gel after cycling: good for presence and size, poor for quantity, and it opens the tube to contamination.
  • Real-time PCR, from 1992 to 1993, reads fluorescence in every cycle in a closed tube, and the cycle at which the signal rises reveals the starting amount relative to standards.
  • Digital PCR, named in 1999, splits the sample into many partitions and counts the positive ones to give an absolute number of molecules.
Created with Claude (Anthropic).