Rules that point to good practice.
+ The questionHow do US agencies tie the standards to their rules, for plants, devices, vehicles and aircraft?
Good practice that the employer must show
The process safety rule of the Occupational Safety and Health Administration, OSHA, is 29 CFR 1910.119. It asks an employer to document that its equipment complies with "recognized and generally accepted good engineering practices", known as RAGAGEP, and it names no standard for safety instrumented systems. The rule counts emergency shutdown systems among the equipment it covers, with controls such as sensors, alarms and interlocks, and it asks that their inspection and testing follow the same practices. It sets no test interval either: the frequency of tests must be consistent with the makers' recommendations and good engineering practice. The proof-test interval of Chapter 11 is therefore a figure the employer sets from those sources.
In Chapter 28's terms the rule is the law and places the duty on the employer, but it names a quality that a practice must have instead of the practice itself. Under OSHA's enforcement memorandum of 11 May 2016, a departure from a "shall" in a practice that the employer follows lets OSHA presume a violation, and a "should" marks a recommendation, an acceptable and preferred practice. The same memorandum holds that internal standards an employer writes for itself must still represent such practices. The rule names no standard, and no standard that the employer follows carries a presumption of conformity in Chapter 28's sense. The presumption that the memorandum describes runs the other way, from a departure to a violation.
For safety instrumented systems, the International Society of Automation, ISA, publishes the US adoption of IEC 61511, the standard of Chapter 22. It lists Part 1 under one title that carries both designations, ANSI/ISA-61511-1-2018 and IEC 61511-1:2016 + AMD1:2017, and Parts 2 and 3 as identical to the IEC parts of 2016, all among its current standards in November 2026. Neither the rule nor the 2016 memorandum names the standard or its predecessor, ANSI/ISA-84.00.01-2004, which adopted IEC 61511 with modifications. The standard therefore enters a plant's compliance through the employer's documentation, not through the rule. The duty to document reaches older equipment too: for equipment designed to codes no longer in general use, the employer must determine and document that it is designed, maintained, inspected, tested and operating in a safe manner.
A class, a route and a recognized edition
For a medical device, FDA's rules start from the type of device. An enclosure in which an infant is kept in a controlled environment for medical care is a neonatal incubator under 21 CFR 880.5400. The regulation places it in Class II, the class that is or eventually will be subject to special controls, and its product code is FMZ. The incubator's route to the US market is the premarket notification, or 510(k): FDA clears a device when it finds the device substantially equivalent to a legally marketed predicate, the device with which the new device is compared. By November 2026 FDA had cleared 86 510(k)s under FMZ, the latest on 28 July 2026. The infusion-pump guide, Every drop accounted for, follows the clearance of infusion pumps in its Chapter 28.
Standards reach the submission through FDA's recognition. FDA keeps a database of recognized consensus standards, each entered by edition, with a date of entry and an extent of recognition, complete or partial. FDA publishes changes to the list in the Federal Register under the Food and Drug Administration Modernization Act of 1997, among them list 066 of 24 August 2026. The use of consensus standards is voluntary, and a standard becomes mandatory only where a regulation cites it, as FDA's training slides on consensus standards state. A maker may declare conformity with a recognized standard in its submission, and such a declaration generally reduces the supporting data the maker must file. A superseded standard that FDA has withdrawn may not be used in a declaration.
A recognition can carry a condition: IEC 60601-1 in its Edition 3.2 of 2020 is recognized with the relevant US national differences applied. Chapter 26 of the biocompatibility guide, What the body meets, shows a partial recognition of a biocompatibility standard. In its 510(k) summary, a maker states which standards the device meets. The summaries of two of the incubators cleared in 2025 and 2026 name those standards in the editions FDA recognizes.
One standard is written into the regulation itself. FDA's Quality Management System Regulation, or QMSR, is 21 CFR Part 820. Since 2 February 2026 it has incorporated ISO 13485:2016 by reference, so the quality system that designs and builds an incubator for the US market answers to that standard's requirements. Where a clause of ISO 13485 conflicts with the Federal Food, Drug, and Cosmetic Act or FDA's regulations, the statute and the regulations control. Through ISO 13485 the regulation now specifically requires risk management.
The guide's incubator (Chapter 4) is a neonatal incubator under 21 CFR 880.5400: Class II, product code FMZ, a 510(k) to FDA. Its file names the six standards of Chapters 4 and 25, each in the edition that FDA's database recognizes in November 2026. They are IEC 60601-1 Edition 3.2 (2020), with US national differences; IEC 60601-1-8 Edition 2.2 (2020), for the alarms; IEC 60601-1-10 Edition 1.2 (2020), for skin mode's closed loop; and IEC 60601-2-19 Edition 3.0 (2020), the incubator's particular standard. The other two are ISO 14971:2019, in its ANSI/AAMI adoption, and IEC 62304 Edition 1.1 (2015). FDA entered these six from January 2019 to April 2023, each recognized in full, and list 066 changed none of them. One edition differs from IEC's catalog. On 9 November 2023 IEC published Edition 3.1 of the particular standard, which consolidates the 2020 edition with its first amendment of 2023. Three years later, in November 2026, FDA's database still lists Edition 3.0 only. The file cites 3.0, as do the makers' summaries of 2025 and 2026 that name the particular standard. One regulation and one product code set the incubator's route, and the file cites each standard in the edition FDA's database recognizes, which for the particular standard is one behind IEC's.
Vehicles under voluntary guidance
NHTSA, the road safety regulator of Chapter 24, deals with the safety of automated driving systems through guidance that it calls voluntary. The guidance carries no compliance requirement and no enforcement mechanism. Under system safety, the first of its 12 safety elements, the guidance asks an entity to document how the entity uses industry standards, best practices, company policies or other methods. A maker that follows ISO 26262 therefore does so by its own choice and records that choice under the guidance. Chapter 24 works through the standard's hazard grading from NHTSA's own assessment of 2016. Entities remain subject to NHTSA's authority over defects, recalls and enforcement, so a vehicle with a defect falls under that authority whatever method its maker followed.
As of November 2026 NHTSA still describes the guidance as voluntary, and its dated steps of 2025 and 2026 concern a policy framework, crash reports, equipment standards and the withdrawal of a proposed program. On 24 April 2025 the Department of Transportation announced NHTSA's Automated Vehicle Framework, a policy of three principles and not a rule. The same day NHTSA issued the third amendment of its Standing General Order on crash reporting, in force from 16 June 2025. The order requires reports of crashes of vehicles with automated driving systems and, on narrower terms, of vehicles with driver assistance at SAE Level 2. For an automated driving system, a crash counts if the system was in use within 30 seconds of it. On 16 March 2026 NHTSA proposed to relieve automated vehicles without manual driving controls of the windshield defrosting, defogging, wiping and washing requirements of two of its safety standards. On 26 June 2026 it withdrew a proposal of January 2025 for a safety and transparency program for vehicles with automated driving systems, AV STEP. None of these documents sets a functional safety requirement or names ISO 26262.
Aircraft: certification after the 737 MAX
FAA approves an aircraft's design with a type certificate and its manufacture with a production certificate, and Chapter 26 shows how FAA recognizes the industry's guidelines for systems and software through advisory circulars. The United States enacted the Aircraft Certification, Safety, and Accountability Act on 27 December 2020, about six weeks after FAA lifted the 737 MAX's grounding (Chapter 26). The Act is Division V of the Consolidated Appropriations Act, 2021, Public Law 116-260. Section 102 of the Act requires FAA to address safety management systems for the holders of both a type certificate and a production certificate.
FAA carried that requirement into its regulations with a final rule on safety management systems, published on 26 April 2024 and in force from 28 May 2024. A safety management system is an organization's own process for managing the safety risk of its work. The rule extends 14 CFR Part 5, FAA's rule on such systems, to holders of a production certificate under Part 21 who hold or license the type certificate for the same product, and to type certificate holders who license their certificate out for production. Holders of a supplemental type certificate, and makers of parts alone, are not covered. Those covered must submit a plan for implementing a system within 6 months of the effective date and, for most of them, have it in place within 36 months.
The Act also reached the delegation of certification work and the safety assessment of systems. In March 2023 Billy Nolen, FAA's acting Administrator, reported to the Senate's Commerce Committee on changes to the Organization Designation Authorization program, among them FAA's approval of certain members of each designated organization's unit. Nolen also reported proposed rules on safety management for design and manufacturing organizations and on system safety assessments for transport category airplanes, and a preliminary review of the assumptions made about pilots' response. Those assumptions come first among the contributing factors that Indonesia's transport safety investigation board, KNKT, listed in time order for the Lion Air accident (Chapter 26).
Four routes to one duty
Set side by side, the four routes differ less in the engineering than in who answers for it and when an agency checks it. OSHA holds the employer to good practice while the plant runs. FDA reviews a maker's 510(k) before the device reaches the market, with its standards cited in recognized editions. NHTSA's enforceable tools for automated driving act once a vehicle is in service, through crash reports and recalls, while its guidance for the design stays voluntary. FAA approves a design and its production. Since 2024 it has asked the certificate holders that its rule covers for a safety management system of their own.
For a US plant, write down the practice each safety instrumented system follows, ANSI/ISA-61511 or another, and the interval and coverage of each proof test with the makers' recommendations behind them, since the rule names neither. For a device, declare conformity with each standard in the edition FDA's database recognizes on the day of the submission, check each recognition's extent and conditions, and record where the design also follows a later IEC edition. For an automated vehicle, document which industry standards the system safety element follows, and set up the crash reports the Standing General Order requires. For an aircraft system, plan the system safety assessment and the organization's safety management system together.
- OSHA's process safety rule asks that equipment, emergency shutdown systems included, comply with recognized and generally accepted good engineering practices and names no standard, so the employer documents the practice it follows and sets test intervals from the makers' recommendations and good engineering practice.
- FDA places the incubator in Class II under 21 CFR 880.5400, clears such a device through a 510(k), recognizes each standard by edition, and since 2 February 2026 incorporates ISO 13485:2016 in its quality rule.
- NHTSA's guidance for automated driving is voluntary, so a maker that follows ISO 26262 does so by its own choice; NHTSA's enforceable tools act once a vehicle is in service, through crash reports and its authority over defects and recalls.
- The Aircraft Certification, Safety, and Accountability Act of 27 December 2020 requires FAA to address safety management systems. FAA's rule of 2024 extends the requirement to production certificate holders who hold or license the type certificate for the same product, and to type certificate holders who license their certificate out for production.