+ Part I · Failure

What a failure is, and which way it falls.

Engineers who design for safety start by refusing to say that a part simply "failed". A thermistor whose resistance has drifted still conducts, still sits in the air it measures and still reports a temperature, so whether it has failed depends on what the function it serves requires of it. This part defines the terms that question needs. Chapter 1 follows the chain from a fault in a part to an error in a value and a failure of the function, and asks what more it takes for harm to follow. Chapter 2 sorts failures by which way they leave the system, toward its safe state or away from it, and by whether the system can see them. Chapter 3 separates the failures that arrive at random from those built in by design, and Chapter 4 assembles a safety function, from its sensor to the part that acts, in an infant incubator.

01 — Faults, errors, failures

What fails, exactly.

+ The questionWhat has gone wrong when a part "fails", and why does the chain from a fault to harm matter?

A failure is judged against a requirement

A fault is a state in which a part cannot perform as required, an error is a value that departs from the true one, and a failure is the event in which an item loses the ability to perform as required. The three words name different things, and they follow one another. A part acquires a fault, and the fault puts a wrong value into the system. Once the wrong value reaches what the system must deliver, it becomes a failure of the system. Each step can stop short of the next, which is why the words are kept apart.

The three definitions follow the vocabulary of the International Electrotechnical Commission, or IEC. In the definition of failure, the words "as required" carry the point. A thermistor is a resistor whose resistance changes with its temperature, and it can age by drifting: its resistance shifts slowly. Whether a drifted thermistor has failed depends on how closely the function it serves must know the temperature. A maker that states how long its thermistors last must first say what it counts as a failure. For its high-stability chips, the sensor maker TE Connectivity counts a change of 1 % in resistance (Chapter 10 takes up such lifetimes).

It follows that a function, not a part, is what fails. In an infant incubator the thermistor's function is to tell the controller the temperature of the air, and the incubator's function is to hold that air within a band around its set temperature (Chapter 4 sets up the incubator in full). If the band can absorb a drift, the function is still delivered. In a design with a narrower band, the function fails under the same drift, although the part is identical in both designs. A failure can therefore be recognized only against a requirement stated as a quantity with its limit.

The chain from a fault to a failure

In the incubator that the later chapters follow, a controller reads a thermistor in the air stream and switches the heater to hold the air at its set temperature. Suppose the thermistor drifts so that it reads lower than the true air temperature. The drifted thermistor is the fault, a state of the part that is present whether or not anything reads it. Each reading it gives is an error, a measured value below the true one. The controller sees air cooler than the set temperature and keeps the heater on until its reading reaches the set temperature. By then the true air is warmer than the set temperature by the size of the drift.

02 — From a fault in a part to harm
FAULT · A STATE ERROR · A VALUE FAILURE · AN EVENT DEMAND HARM CONTROL THERMISTOR RESISTANCE HAS DRIFTED the part's own failure left this state TRUE READ READS BELOW THE TRUE AIR TEMPERATURE CONTROLLER HEATER KEPT ON REQUIRED BAND INCUBATOR AIR AIR LEAVES ITS BAND: CONTROL FUNCTION LOST the function fails; no part has broken THE HAZARD: HEAT PROTECTIVE CHANNEL: OWN SENSOR, CUTS THE HEATER CHAPTER 4 CHANNEL ANSWERS: HEATER OFF CHANNEL ALREADY FAILED, UNSEEN: HEAT REACHES THE INFANT INSIDE THE PART → INSIDE THE SYSTEM → WHAT THE SYSTEM DELIVERS Schematic. The incubator is set up in Chapter 4.
Basic controlDangerous failureSafe stateSafety functionFocal detail
Plate 02 — A drifted thermistor is a fault, its low reading an error, and the air leaving its band the failure of the control function, while no part has broken. That failure creates a demand on the protective channel once the air reaches the limit, and harm follows only if the channel has already failed.

Up to a point the function absorbs the error, because a control loop always swings a little around its set point and the requirement allows for that swing. Past that point the air leaves the band it must stay in, and the incubator has lost its ability to perform as required: its control function has failed. Nothing breaks at that moment. The heater heats, the controller switches the heater by the reading it receives, and the thermistor still conducts and reports a temperature, so the failure lies in what the three deliver together. The requirement and the loop's own swing fix that moment.

Solved example: the drift at which an error becomes a failure

The incubator's own figures are Chapter 4's, so the example uses a stand-in: a low-cost, open-source incubator that Cuervo and colleagues built and described in a 2023 paper. In bench tests of the one prototype, they measured its air temperature, humidity, air speed and noise. Its sensor is not a thermistor, but any sensor that reads low acts on the loop in the same way. The authors required the air in steady state to stay within 0.5 °C of the set temperature. At a set temperature of 36 °C the prototype held the air within 0.1 °C either side. The arithmetic that follows assumes that a drift shifts this swing without widening it. A sensor that reads 0.3 °C low puts the true air at 36.3 °C, swinging between 36.2 and 36.4 °C, inside a band that ends at 36.5 °C. A sensor that reads 0.5 °C low puts the air at 36.5 °C, swinging up to 36.6 °C, outside the band at the top of every swing. The boundary lies where the drift and the 0.1 °C swing together reach 0.5 °C, at a drift of 0.4 °C. For this prototype, a drift of up to about 0.4 °C is an error that the function absorbs; beyond it the control function has failed, while no part has broken.

The chain repeats at every level of a design. Within one part the order runs the other way: the failure is the event, and the fault is the state it leaves in the part. The thermistor's own failure is the moment its drift passes what is required of it. The thermistor then stays in its drifted state, and that state is the thermistor's fault. Seen from the incubator, that faulted part puts errors into the readings the system works from. A part's failure is thus a fault of the system that contains it, and the chain starts again one level up. An error can also come from a systematic fault, one that is built into the design and lies dormant until some circumstance calls on it (Chapter 3).

A failure mode belongs to the part

Where a failure belongs to a function, a failure mode belongs to a part: it is the way the part departs from what it should be, as seen at its terminals. A thermistor has three. Its circuit can open, so that no current flows; it can short, so that its resistance falls to almost nothing; or its resistance can drift. For thermistors in general, the open circuit is the most common mode and the short circuit the least common, in the ranking of the US Navy's parts guidance. In an NTC thermistor, one with a negative temperature coefficient, the resistance falls as the part warms. NTC thermistors seldom fail outright and instead drift, and one cause of the drift is micro-cracks spreading in the ceramic, as TE Connectivity states in a 2021 white paper.

Each mode reaches the controller as a different error, because the controller turns the resistance it measures into a temperature. An open circuit measures as a resistance without limit, far above what an NTC thermistor shows in any air an incubator holds. A controller with no check on its readings then sees extreme cold and drives the heater at full power. A short measures as almost no resistance, which reads as air hotter than any incubator could hold, and the heater stays off. A drift that raises the resistance makes the reading low by an amount small enough to look ordinary, and the heater stays on longer than it should. A design that depends on a thermistor therefore has to answer all three modes, whichever of them is the most common.

03 — A thermistor's three failure modes and the errors they make
RESISTANCE TEMPERATURE NTC: RESISTANCE FALLS AS THE PART WARMS MODE WHAT THE CONTROLLER MEASURES WHAT IT READS WHAT THE HEATER DOES OPEN CIRCUIT MOST COMMON, FOR THERMISTORS IN GENERAL NO CURRENT: RESISTANCE WITHOUT LIMIT COLDER THAN ANY REAL AIR IMPOSSIBLE READING: A CHECK CAN SEE IT FULL POWER DRIFT AGES THIS WAY (MAKER'S STATEMENT, NTC) RESISTANCE SHIFTED A LITTLE: THE MAKER COUNTS 1 % AS FAILED A LITTLE LOW, IF THE RESISTANCE ROSE PLAUSIBLE READING NO SIGN ON LONGER THAN IT SHOULD the error looks like a true reading SHORT CIRCUIT LEAST COMMON ALMOST NO RESISTANCE HOTTER THAN ANY REAL AIR IMPOSSIBLE READING OFF away from overheating Ranking: US Navy parts guidance, thermistors in general. Drift: TE Connectivity white paper, 2021 (maker). Schematic.
Dangerous failureSafe stateDiagnosticsFocal detail
Plate 03 — An open circuit and a short give readings that no real air could produce, so a check can see them. A drift that makes the reading low keeps the heater on a little longer, and nothing in the reading shows it.

The size of an error matters as much as its direction. An open circuit or a short gives a reading that no real air could produce, and a controller can be built to recognize such a reading and act on it, as Chapter 12 shows. A drift gives a reading that real air could produce, so nothing in the reading shows that it is wrong. A stuck output is a fourth mode, one that a thermistor lacks, and it misleads in the same way: the reading holds still while the quantity moves on, as the opening's gauge did. Chapter 2 sorts failures by two questions: which way an error pushes the heater, toward overheating or away from it, and whether the system can see the error at all.

Harm needs a hazard and a demand

A failure of the control function is not yet harm. While the heater stays on, the air can grow hot enough to injure the infant, and that hot air is the hazard, a potential source of harm. Harm needs that heat to reach the infant. Such harm is documented. In a 2005 case report, Fineschi and colleagues, forensic pathologists, described an infant of eight days who died of heat stroke in an incubator. The report records that examination of the incubator found a malfunction of its "temperature and relative humidity control system".

A second, separate circuit stands between the hazard and the infant: the protective channel that Chapter 4 sets up. The channel watches the same air with its own sensor and cuts the heater if the air passes a limit. It is needed only once the control has failed and the air has reached that limit. That moment is a demand, the occasion on which a safety function must act, and the control failure creates it. Harm from the drifted control thermistor therefore needs the hazard, a demand and one thing more: a protective channel that fails to answer the demand. A failure of control met by a working protective channel ends with the heater off. A failure in the protective channel alone does no harm while no demand comes.

Suppose the same drift struck the protective channel's thermistor instead. The controller would go on holding the air at its set temperature. The protective channel does nothing in normal operation, and it would sit with a reading that is too low and a limit that the true air would pass before the channel acted. Nothing would show until a demand came. The hidden drift is an instance of the one fact that Before we start sets out and every chapter uses: every part eventually fails, and some failures stay hidden until the moment the part is needed. The opening's two failures fit the same pattern. The stuck gauge let the tank fill to the level of the independent high-level switch. The level reaching the switch was the demand on it. After the periodic tests of the switch, its test lever had been left in the position that disabled the switch, or free to fall into that position, so the switch had already failed when that demand came (Chapter 11).

A failure begins at the loss, often long before it shows

For a function that acts all the time, such as the incubator's control, the loss shows at once in the air temperature. For a function that waits, such as the protective channel, the ability can be lost on one day and the loss found months later, when a demand or a test reaches the function. The failure dates from the loss, so a record that dates the failure from its discovery understates how long the protection was missing. Chapter 11 sets the proof-test interval by weighing how long such a loss can stay hidden.

The chain from a fault to harm matters because a design can break it at each link. A part whose failure modes are known and answered stops the chain at the part. A check that turns an impossible reading into an alarm stops it at the error (Chapter 12), and a separate protective channel stops it at the demand (Chapter 4).

Write the requirement, then trace every mode

Write each requirement of a function as a quantity, its limit and its time, so that a failure can be recognized when it happens: the air within a stated band of the set temperature in steady state, the heater cut within a stated time once the air passes its limit. For each part, list its failure modes and follow each one through the chain: the error it puts into the system, which way that error pushes the output, and whether anything in the design would show it. Treat a drift as seriously as an open or a short circuit, since its error looks like a true reading. When a part is replaced in service, record the mode in which it failed as well as the part, so that the records show which modes the design meets in use.

+ What this chapter established
  • A fault is a state in which a part cannot perform as required, an error is a value that departs from the true one, and a failure is the event in which an item loses the ability to perform as required.
  • A failure belongs to a function and is judged against its requirement, so a drifting sensor can leave the incubator's control failed while no part has broken.
  • A failure mode belongs to a part: a thermistor can open, short or drift, and only a drift gives a reading that real air could produce.
  • Harm needs a hazard and a demand met by a failed protection, and a protection that does nothing in normal operation can stay failed, unseen, until a demand or a test reaches it.