+ Part III · Numbers
Counting failures.
The random part of safety can be counted, and Part III counts it with numbers a calculator can check. Random hardware failures, which Chapter 3 set apart from systematic ones, arrive at rates that can be estimated. The probability that a protective function fails when it is needed follows from those rates and a few design choices. Chapter 10 asks what a failure rate measures and where its numbers come from. Chapter 11 turns the rate of hidden failures and the interval between proof tests into an average probability of failure on demand. Chapter 12 counts the failures a system detects in itself, Chapter 13 weighs what a second or third channel adds, and Chapter 14 follows the common causes that defeat redundant channels together. The failures that no rate describes, the systematic ones, are the subject of Part IV.
Failures per hour.
+ The questionWhat does a failure rate measure, and where do the numbers come from?
A rate describes a population
A FIT is one failure in a billion hours of operation, 10⁹ hours, so a component with a failure rate of 100 FIT is expected to fail once in 10 million hours. Those 10 million hours come to about 1,140 years, and the figure is therefore not a forecast of how long one part will last. It describes a population. If 1,000 such components run for 10,000 hours, a little over a year, they add up to 10 million component-hours between them, and in that time one of them is expected to fail.
The failure rate is the fraction of the parts still working that fail in each hour of operation, and it is written λ, the Greek letter lambda. The fraction is taken among the survivors because a part that has already failed cannot fail again. For the parts of a safety function the fractions are small: 100 FIT is a chance of 1 in 10 million per hour, and the FIT lets such small rates be written as whole numbers. A rate for one of the four failure classes of Chapter 2 carries the class as a subscript, so λDU is the rate of dangerous undetected failures and λDD that of dangerous detected ones.
The rate is an expectation, and the count of failures in a real population scatters around it: in their 10 million component-hours the 1,000 components may lose none of their number, or two. A count measures a rate closely only when it holds many failures. At 100 FIT one failure is expected in every 10 million component-hours, so counting the failures of good parts needs many parts running for a long time. Where no such count exists, the rate has to be predicted.
A constant rate belongs to the flat of the bathtub
Over a part's whole life its failure rate is not constant. Chapter 3's bathtub curve shows the rate falling through the early failures, staying flat through the useful life and rising again as the part wears out. On the flat stretch the rate does not depend on age: a part five years into its useful life is as likely to fail in the next hour as one a few months into it. Failures on the flat stretch come at random times, with nothing in a part's history to say when, and they are the random hardware failures of Chapter 3. The calculations in Part III take each rate as constant over the useful life, as reliability calculations commonly do even where the assumption holds only roughly.
A constant rate keeps the arithmetic simple. While the product of rate and time stays small, the chance that a part fails within a period is about the rate multiplied by the period. At 100 FIT that chance is about 1 in 100,000 in 100 hours, and about 1 in 1,140 in a year of 8,760 hours. The working hours of different parts can also be added, since a failure is as likely in any hour on the flat as in any other. The same expected count comes from 1,000 parts running for 10,000 hours and from 10,000 parts running for 1,000 hours, so a rate can be estimated from many units, each observed for a short time.
The mean time to failure, or MTTF, is the average working time before a part fails, the "expectation of the operating time to failure" in IEC's vocabulary. With a constant rate the MTTF is the reciprocal of the rate. A population that loses one part in 10 million each hour runs, on average, 10 million part-hours for each failure, so a rate of 100 FIT and an MTTF of 10 million hours are the same statement. The MTTF is therefore not a lifetime. It holds only while the rate stays on the flat, and an MTTF of 1,140 years says nothing about when wear-out begins.
IEC's vocabulary has a second figure for a part that is repaired and put back into service: the mean time between failures, or MTBF, which "should only be applied to repairable items". A thermistor is replaced when it fails, not repaired, so for such a part the figure to ask for is the rate, or the MTTF that follows from the rate.
Three ways to arrive at a number
The direct way to a rate is to count. Field data are the failure records of parts in service. The rate they give is the number of failures divided by the operating hours the population has accumulated, and a constant rate allows those hours to be pooled across units and sites. OREDA, a not-for-profit collaboration of energy companies, gathers such records. Its site counts 21,000 items of topside equipment and 47,000 topside failure records, and says that energy companies have trusted it since 1981. A count reflects real service, but only the service of its own population, which for OREDA is the equipment of energy companies, and only the failures that someone found and recorded. A dangerous undetected failure enters a record when a proof test or a demand reveals it (Chapter 11).
Where no count exists, the second way is to predict the rate. A prediction handbook gives each type of component an expected rate under reference conditions, with models that adjust the rate for the stresses of use, temperature among them. The US military handbook MIL-HDBK-217F has models for thermistors and for mechanical relays. It was issued in 1991 and last changed by a notice of 1995, and a validation notice of 2022 kept it active without adding data. Another such source is SN 29500, Failure Rates of Components: Expected Values, a Siemens company standard issued in parts by type of component. Both give the expected value for a type of part, not a measurement of any one part.
A device made for safety functions can carry a third kind of figure, from a failure modes, effects and diagnostic analysis, or FMEDA, a method that Chapter 18 sets out in full. An assessor goes through the device's components and gives each a rate from a handbook. For each way a component can fail, the assessor then decides whether the device's output becomes safe or dangerous and whether the device's own checks detect that failure. Summed class by class, the results give the device's rate in each of Chapter 2's four classes. The rates are calculated, not counted, so they inherit the handbook's figures and the assessor's judgments, and they hold for the conditions the analysis assumes.
One transmitter's rates, and their conditions
The PR5337 temperature transmitter shows what an FMEDA states. The transmitter reads a temperature sensor and sends the reading on as a current between 4 and 20 mA. In a report of 2016, the assessor exida, a certification and consulting company, analyzed the transmitter for its maker, PR electronics, with component rates from SN 29500. For the input from a resistance thermometer, the analysis gives 203 FIT of dangerous detected failures and 71 FIT of dangerous undetected failures, 274 FIT of dangerous failures in all. Besides these the analysis gives 1 FIT of a small class it calls annunciation undetected, and no safe failures. With a thermocouple input the two dangerous figures are 205 and 74 FIT. At 274 FIT one transmitter has a chance of about 1 in 420 of a dangerous failure in a year, and its mean time to a dangerous failure is about 420 years.
In the report's words, each of those rates holds "for an average temperature of 40°C over a long period". At an average of 60 °C the rates are multiplied by 2.5, and by the same factor where the temperature swings by more than 15 °C a day. The analysis also assumes a function in low-demand mode, one input and one output channel, and internal faults detected within 5 minutes at worst. Last, it assumes a logic solver set to detect currents above and below the normal range, as the recommendation NAMUR NE43 describes. The 203 FIT count as detected only under that condition, since the detection is the logic solver's reading of an out-of-range current. Chapter 12 takes up that detection.
The transmitter's 71 FIT hold for an average of 40 °C. In equipment that averages 60 °C, or swings by more than 15 °C a day, the report's factor of 2.5 makes the rate 177.5 FIT. Every quantity computed from the rate grows in proportion, so the chance of a dangerous undetected failure in a year rises from about 1 in 1,600 to about 1 in 640. A rate is valid for its own conditions, and those conditions are checked against the place where the part will run.
The makers' own figures come in other units
The incubator's own parts come with figures of another kind. For the thermistor, whose drift Chapter 1 described, the sensor maker TE Connectivity gives a mean time to failure in a 2021 white paper. In that figure a failure is a change of 1 % in resistance at an operating temperature of +30 °C. For eight types of the maker's high-stability chips the times run from 66 to 365 years. The maker held unpowered chips at +50 to +150 °C for up to 10,080 hours, about 14 months, and calibrated them at set times during the test. It then carried the drift down to +30 °C with the Arrhenius model, which relates the speed of a process to its temperature. The tests span less than 2 % of the shortest lifetime they predict, and the Arrhenius model supplies the rest.
A drift lifetime is not a constant rate. Drift builds up with time, so an old thermistor is nearer the 1 % limit than a new one, and its chance of crossing the limit in the next hour grows with age. The figure therefore describes the rising end of Chapter 3's bathtub, not its flat stretch. The maker's figure also counts drift in either direction, although in the protective channel a drift delays the trip only if it makes the reading low (Chapter 1). Whether a drift of 1 % is a failure at all depends on how closely the function must know the temperature.
The incubator's cutout can be built with a relay, a switch whose contacts an electromagnet opens and closes, and the maker of a relay states the relay's reliability per operation. One relay maker gives the failure rate as a P level: one failure expected "once in every 10 million cycles" when the relay is opened and closed continuously at a small specified load, under the Japanese standard JIS C 5003. The FAQ that states the P level is now published by Aratas Corporation, formerly Omron Components. A figure per operation becomes a rate per hour only when it is multiplied by the number of times the part operates in an hour. The cutout operates at a demand or a test. Chapter 11 needs the hourly rate of the failures that would stop the cutout opening on a demand.
The transmitter's figures are already rates per hour: 71 FIT of dangerous undetected failures and 274 FIT of dangerous failures in all, at an average of 40 °C. The thermistor's lifetimes become rates only by assuming a constant rate. The shortest, 66 years, is 66 × 8,760, about 578,000 hours, and 10⁹ ÷ 578,000 is about 1,700 FIT; the longest, 365 years, gives about 310 FIT. The relay's figure needs a number of operations per hour. Switched once a minute, 60 times an hour, the relay is expected to fail 60 times in 10 million hours, or 6,000 FIT; switched once a year, at a test, the same relay comes to about 0.01 FIT. The three sources thus give numbers from about 0.01 to 6,000 FIT. Only the transmitter's 71 FIT is a rate per hour of dangerous undetected failures at stated conditions, and that rate is the input Chapter 11 uses.
Why the sources disagree
The figures for one kind of part differ between sources, and the reasons follow from what each source does. Each counts a different event: a drift past a limit, any failure under a test, or the dangerous failures that a device's own checks miss. Each holds for its own conditions. For converting a rate from one set of conditions to another, IEC 61709:2017 sets out reference conditions and stress models, and it states that it provides no base failure rates. Each source also rests on a different method: counts from records, a handbook's models, an assessor's analysis built on a handbook, or the physics of failure, on which the FIDES method bases its predictions in its current guide of 2022.
Predictions can differ widely from performance in service. In a 1999 study, Jones and Hayes, both of Loughborough University, compared five prediction models with the field failure records of several circuit boards. Among the five were MIL-HDBK-217, in its edition E, and SN 29500. The records had been collected over many years from British and Danish electronics makers. The predictions differed greatly from one another and from the boards' performance in service. A handbook rate, or an FMEDA built on one, is therefore an expected value that service has to confirm. The failures that proof tests find are the records that confirm or correct that value (Chapter 11).
Ask a supplier for the rate per hour of each failure class, with the conditions it holds for, the method behind it and who produced it; the transmitter's FMEDA states all four. Convert a lifetime or a per-operation figure only with the assumption written beside the result, and do not treat a time to drift as a constant rate. Check the stated temperature against the enclosure where the part will sit, and apply the source's own factor where the two differ. Record the failures found in service, and compare their count with the count the predicted rate gives over the hours accumulated.
- A failure rate is the fraction of working parts that fail in each hour, so it describes a population: at 100 FIT, 1,000 parts running for 10,000 hours are expected to lose one.
- On the flat of the bathtub the rate is taken as constant, so the MTTF is the reciprocal of the rate, not a forecast of how long one part will last.
- Rates come from field counts, prediction handbooks and FMEDAs built on handbooks, and each holds for its own event and conditions: the transmitter's 71 FIT of dangerous undetected failures hold at an average of 40 °C.
- The makers of the incubator's parts state a time to a 1 % drift and a failure per operation, figures that become rates per hour only by assuming a constant rate or a number of operations per hour.