Where the line is drawn.
+ The questionWho decides how much risk is acceptable, and on what grounds?
Two lines for the risk to one person
Great Britain's safety regulator treats a risk of death of 1 in a million a year as broadly acceptable. Chapter 5 turned hazards into numbers that can be compared, but a comparison cannot say when a risk is low enough, so a decision also needs a reference line. That regulator is the Health and Safety Executive, HSE, and it draws two such lines for individual risk, the yearly probability that a particular person is killed by an activity. A worker in a given job is one such person, and a resident at a given address is another. A risk above the upper line is intolerable and has to be brought below it, and a risk below the lower line is broadly acceptable. Between the two lines, a risk is tolerable only once it has been reduced as far as is reasonably practicable.
HSE first published its report on the tolerability of risk from nuclear power stations in 1988 and set out the figures in the report's 1992 edition. In 2001 HSE carried the figures into its general framework, Reducing risks, protecting people, or R2P2, which remains its published account of how it decides. The upper line for workers rests on what workers in fact accept: a risk of death of about 1 in 1,000 a year is the most that substantial groups of workers ordinarily accept, as the 1992 report observes. For members of the public HSE set the upper line 10 times lower, at 1 in 10,000 a year. The lower line, 1 in a million a year, applies to both.
Tolerable does not mean acceptable: a tolerable risk is lived with on condition that it is reduced as far as is reasonably practicable. The two lines divide individual risk into three bands, often drawn as an inverted triangle that is wide at the top, where the risk is greatest, and narrows toward the foot. The duty changes from band to band. In the top band the risk must come down below the line. In the middle band the risk must be reduced as far as is reasonably practicable, and a risk in the band at the foot "need not claim attention", as HSE's 1992 report puts it.
Between the lines, cost is weighed against risk
The law places a duty on the duty-holder, the employer or operator, to reduce risk so far as is reasonably practicable, and that duty governs the middle band. HSE expresses the duty as reducing risk as low as reasonably practicable, or ALARP. Reasonably practicable is narrower than physically possible. A measure that would reduce the risk has to be taken unless its cost is grossly disproportionate to the reduction it brings, and the duty-holder must be able to show that it is. The test of gross disproportion comes from the courts: the Court of Appeal set it in 1949, in Edwards v National Coal Board.
The test leans toward safety. In an ordinary weighing of cost against benefit, a measure is adopted only if its benefit exceeds its cost. Under ALARP a measure is presumed adopted, and it can be ruled out only if what it would cost is grossly disproportionate to the risk it removes. The lean grows with the risk, since employers are expected to spend proportionately more to reduce a higher risk. HSE's guidance for its inspectors of major hazard sites expressed the lean as a factor of disproportion, the number of times a measure's cost must exceed its benefit before the cost counts as grossly disproportionate. That guidance has since been withdrawn. One of its documents set the factor at no less than 1 near the lower line and no less than 10 near the upper one. Another called 10 a suggested upper value and said that how the factor changes with risk was still unclear. In each case the factor's value was a matter of professional judgment.
A worker on a fuel depot shows the figures at work. In the absence of other information, PSLG's guidance recommends a conservative approximation: anyone within 250 m of the wall of an overfilled tank is taken to die if its vapor cloud explodes, unless inside a building designed against blast. The Buncefield cloud had spread 250 m to the north. A worker's individual risk from such an explosion is its frequency multiplied by the share of the time the worker spends within that radius. That share is one of the conditional modifiers of Chapter 7. If the explosion were expected once in 10,000 years and the worker spent a fifth of the year inside the radius, the risk would be 2 in 100,000 a year.
That risk lies 50 times below the worker's upper line and 20 times above the lower one, so it is tolerable only if it is ALARP. Under PSLG's guidance, any individual risk above 1 in a million a year calls for further risk reduction to be considered. The depot's operator must therefore take each further measure, such as an automatic trip that stops the fill, unless the operator can show the cost to be grossly disproportionate to the risk removed. Where the depot is a major hazard site, the Control of Major Accident Hazards Regulations 2015, known as COMAH, set out the operator's general duties and the competent authority that regulates the site. A safety report is a further duty at an upper-tier site, the tier for sites that hold the larger quantities of dangerous substances.
Individual risk belongs to a person, so it adds up every hazard of the activity that can reach that person: an overfill, a leak, a fire. A study that held each scenario separately to the whole of a worker's or a neighbor's limit could leave the person's total several times above that limit, one share for each scenario. PSLG's guidance gives risk criteria for single scenarios, and it points out that a scenario-based assessment with a single fatality is not the same as an individual risk calculation. A target for one scenario therefore sits below the individual limit, and further below it the more scenarios reach the same person.
Many deaths at once
Neither Chapter 5's product nor individual risk shows how the harm arrives. An accident that kills 50 people once in 5,000 years has the same product as one that kills one person once in 100 years. A neighbor of a depot also runs the same individual risk whether the depot's explosion would kill one person or 100. Societal risk measures what both leave out, by relating the number of people killed in one accident to how often accidents of that size occur. It is drawn as an F-N curve: N, a number of deaths, runs along the bottom, and F, the frequency a year of accidents that kill N or more people, runs up the side, both in tenfold steps.
The UK's criterion for societal risk is a single point. In R2P2, an accident that kills 50 or more people is intolerable if it is estimated to occur more than once in 5,000 years, a frequency of 2 in 10,000 a year. When HSE issued its guidance on ALARP at major hazard sites, no other UK criterion for societal risk had been adopted, and no line runs through the point in R2P2. That guidance is now withdrawn. The lines it drew for societal risk had a slope of 1, so that the frequency falls tenfold for each tenfold rise in deaths. Along such a line the product of frequency and deaths stays the same: it is a line of equal expected harm, and it weighs a large accident by its average harm alone.
The Netherlands drew a steeper line. Until 1 January 2024, the societal risk around a hazardous establishment was compared with a line that put accidents killing 10 or more people at 1 in 100,000 a year. The line fell a hundredfold for each tenfold rise in deaths, a slope of 2. Along the Dutch line, the expected deaths from accidents of each size fall tenfold for each tenfold rise in size, so a large accident has to be rarer than its share of the average harm alone would require. Dutch risk rules of that period called such a value an orientation value, against which a calculated societal risk was compared. The Omgevingswet, the Dutch environment and planning act, entered into force on 1 January 2024. Under it, group risk, as the Dutch rules call societal risk, carries no norm, only a duty to account for it. A limit of 1 in a million a year on the risk at a given location still applies to vulnerable buildings.
The Dutch line passes 10 deaths at 1 in 100,000 a year and falls with the square of any rise in deaths. At 50 deaths, N is 5 times 10, so the line has fallen by 5 squared, 25, to 1 in 100,000 ÷ 25, which is 4 in 10 million a year. The UK's point puts accidents of 50 or more deaths at 2 in 10,000 a year. Dividing the UK's value by the Dutch one, 2 in 10,000 ÷ 4 in 10 million, gives 500: at 50 deaths, the Dutch line as it stood before 2024 lay 500 times below the UK's boundary of the intolerable. The UK's value served as that boundary and the Dutch value as an orientation value, so the factor of 500 measures how far apart the two criteria were drawn and says nothing of the risk that either country's sites ran.
Two other references: the system replaced and the natural death rate
Railway practice adds two references of other kinds. GAMAB is a French transport principle whose initials stand for "globalement au moins aussi bon": a new system must offer a level of risk globally at least as good as that of the system it replaces. Part 2 of the European railway standard EN 50126 calls the same idea GAME, "globalement au moins équivalent". Part 2 was issued in 2017 and lists GAME with ALARP and MEM among the criteria for accepting railway risk. GAMAB needs no absolute figure, because its reference is the risk of a system already in service.
MEM, minimum endogenous mortality, takes its reference from deaths by natural causes. Children aged 5 to 15 in developed countries have the lowest natural death rate of any age group, 2 in 10,000 a year, and MEM asks that no single technical system add significantly to that rate. In figures, no one system should add more than 1 in 100,000 a year to a person's risk of death, a twentieth of the lowest rate. MEM is widely used in railway safety, especially in Germany. The references in this chapter are set by different owners: HSE for its lines, the courts for the test of gross disproportion, Dutch national rules for the Dutch line, and the railway standard for GAME and MEM.
A newborn's harm beside its benefit
A newborn in Chapter 4's incubator differs from the worker and the neighbor in one respect that changes the grounds of the decision. Overheating is a harm that can reach death (Chapter 1). The infant who bears the risk of overheating is the same infant who receives the benefit of the heat. The safe state carries a harm of its own, since an unheated incubator lets the infant cool. A lower trip limit also comes closer to what normal control does (Chapter 4). A protection set to act sooner would therefore trip more often on a working incubator, trading some harm from overheating for more harm from cooling in the same patient.
Medicine judges what remains of a device's risk against what the device gives the patient. ISO 14971:2019 is the standard for risk management of medical devices. Under it, the risk remaining after risk control measures have been implemented is the residual risk, and a benefit–risk analysis justifies why the benefits outweigh the residual risk. That weighing is part of the maker's risk management. Medical device standards state their requirements in other terms and use no integrity levels. This book still gives the incubator's overtemperature protection an integrity level by the arithmetic of Chapters 7 and 8, but how much risk the protection may leave behind is judged in the weighing, for the infant who bears both the risk and the benefit. Chapter 25 follows the weighing through ISO 14971's risk control and the device standards.
Before the analysis that sets a safety function's target, record the risk criteria it will use, each with its owner, its source and its status on the day. Say what each is: a regulator's framework, a client's figures, an orientation value replaced in 2024 or guidance since withdrawn. State whom each criterion protects: a worker, the public or a group. Hold the sum of the hazards that reach one person to an individual limit, not each scenario on its own. Where a risk falls between the lines, list the further measures considered and why each was taken or judged grossly disproportionate. For a medical device such as the incubator, set the criteria in its ISO 14971 risk management and weigh the residual risk against the benefit to the patient (Chapter 25).
- HSE draws two lines for the risk to one person: an upper one at about 1 in 1,000 a year for workers and 1 in 10,000 a year for the public, and a lower one at 1 in a million a year. The figures come from the 1992 edition of its tolerability report, and HSE carried them into R2P2 in 2001.
- Between the lines a risk is tolerable only if it is as low as reasonably practicable: a measure may be left out only if the duty-holder can show that its cost is grossly disproportionate to the risk it removes, a test that comes from the courts.
- Societal risk relates the number killed in one accident to how often accidents of that size occur. The UK's criterion is one point, 50 or more deaths at 1 in 5,000 a year, and the Dutch line in use until 2024 lay 500 times below it at 50 deaths.
- Railways also judge risk against the system being replaced (GAMAB) or the lowest natural death rate (MEM), and medicine weighs a device's residual risk against its benefit to the patient who bears the risk (Chapter 25).