08 — Integrity levels

From the gap to a level.

+ The questionHow is the gap between the risk there is and the risk accepted turned into an integrity level?

The shortfall becomes a factor

A safety function that must cut a risk a hundredfold may fail on no more than one demand in 100. The reason lies in the rule of Chapter 7 that independent layers multiply: each layer multiplies the frequency of the consequence by its probability of failure on demand. A layer added to divide that frequency by 100 may therefore let through at most one demand in 100, and a layer added to divide it by 1,000 at most one in 1,000. The factor and the probability state a single requirement, since each is 1 divided by the other.

The factor is the risk reduction factor, or RRF: the frequency of the consequence with every credited layer in place, divided by the frequency judged tolerable. It is the shortfall that a LOPA leaves. In a worked example from a safety consultancy's training course, the pressure control of a distillation column fails about once in 10 years. A relief valve lets one demand in 100 pass, so the column overpressures about once in 1,000 years, against a target of once in 100,000 years. The shortfall is a factor of 100, and the instrumented function added to close it may fail on no more than one demand in 100.

The factor sets how rarely the function may fail, not why it would fail. Random failures of parts arrive at rates that can be estimated, so their share can be computed from failure rates and test intervals (Chapters 10 and 11). Systematic failures follow from how the function is specified, built, checked and kept: a wrong requirement, for example, or a fault that every copy of the software carries (Chapter 3). No failure rate counts them. The integrity of a safety function is how rarely it fails to do its job when called on, from either cause, and an integrity level states the required integrity as a band.

Four bands, each a tenfold step

A factor computed from values rounded to tenfold steps is no more exact than a tenfold step, and the requirement is set in bands of that width. IEC 61508:2010 is the general standard for safety functions carried out by electrical, electronic and programmable systems, and it defines four such bands, the safety integrity levels, SIL 1 to SIL 4. For a function that is seldom called on, each band is a range of the PFDavg of Chapter 11: the probability, averaged over time, that the function has failed and would not answer a demand. The higher the level, the rarer the failures it allows.

SIL 1 covers a PFDavg from 1 in 100 up to 1 in 10, SIL 2 from 1 in 1,000 up to 1 in 100, SIL 3 from 1 in 10,000 up to 1 in 1,000, and SIL 4 from 1 in 100,000 up to 1 in 10,000. Each band includes its lower limit and stops short of its upper one. As a risk reduction factor, SIL 1 means more than 10 and up to 100, and each level above it means 10 times more. Chapter 11 computes a function's PFDavg and compares it with these bands.

Because LOPA's values move in tenfold steps, the factor it yields usually falls on a boundary between two bands. A factor of 100 asks for a PFDavg of no more than 1 in 100, which is the boundary itself. A SIL 1 function meets that only at the best edge of its band, and a SIL 2 function meets it anywhere in its band. The consultancy's training course also gives a table of LOPA credits, which takes each level at the weak edge of its band. It puts a SIL 1 function at 1 in 10, the credit that Chapter 7's trip received, a SIL 2 function at 1 in 100 and a SIL 3 function at 1 in 1,000. So a factor of 10, 100 or 1,000 is met throughout the band by SIL 1, 2 or 3. A factor between two steps, such as 30, sets the function's own target, 1 in 30, inside the SIL 1 band.

The level belongs to the whole function

The whole function, from its sensor to its final element, must meet the target, and the PFDavg shares of its parts add up (Chapter 11). A sensor whose own figure falls in the SIL 3 band can therefore sit in a function that reaches only SIL 2, once the comparison and the cutout add their shares. A certificate that calls a part "SIL 3 Capable" states what the part can be used for, and the function built from it still has to meet its own target (Chapter 21).

How often the function is called

The PFDavg suits a function that waits. Between rare demands a hidden failure has months or years in which to arrive and stay hidden (Chapter 11). So what decides harm is whether the function has failed when the call comes, and the frequency of harm is the demand rate multiplied by that probability (Chapter 5). A function called on many times between its tests behaves differently. A dangerous failure in such a function meets a demand within days or hours, long before a test could reveal it, so nearly every dangerous failure is followed by harm. The frequency of harm then approaches the frequency of dangerous failures, and the demand rate drops out of the product.

IEC 61508:2010 sorts functions by this difference into modes of operation, set by the demand rate. The boundary lies at one demand a year: a function called on no more than once a year is in low-demand mode, and its target is a PFDavg. A function called on more often is in high-demand mode, and one whose demand never stops, because it acts all the time, is in continuous mode. Functions in both modes are judged by the frequency of dangerous failures per hour, the PFH. SIL 1 asks for fewer than 1 dangerous failure in 100,000 hours, about once in 11 years. Each level above it asks for 10 times fewer, down to SIL 4's band of 1 in 100 million hours to 1 in a billion.

16 — The four safety integrity levels in both modes
LOW DEMAND: AT MOST ONE DEMAND A YEAR HIGH DEMAND OR CONTINUOUS: MORE THAN ONE A YEAR, OR NEVER-ENDING LEVEL PFDavg, PER DEMAND RISK REDUCTION FACTOR PFH, DANGEROUS FAILURES PER HOUR SIL 4 1 in 100,000 to 1 in 10,000 more than 10,000, up to 100,000 1 in a billion to 1 in 100 million SIL 3 1 in 10,000 to 1 in 1,000 more than 1,000, up to 10,000 1 in 100 million to 1 in 10 million SIL 2 1 in 1,000 to 1 in 100 more than 100, up to 1,000 1 in 10 million to 1 in a million SIL 1 1 in 100 to 1 in 10 more than 10, up to 100 1 in a million to 1 in 100,000 PFDavg 1 in 100,000 1 in 10,000 1 in 1,000 1 in 100 1 in 10 the incubator's cutout: no more than 1 in 1,000 (SIL 3) Each band includes its lower limit and stops short of the upper one. 1 in 100,000 hours is about once in 11 years. Bands of IEC 61508:2010.
Safety functionFocal detail
Plate 16 — Each level is one tenfold step, counted per demand for a function called on no more than once a year and per hour for one called on more often or all the time. On the chapter's stand-in inputs, the incubator's cutout, at no more than 1 in 1,000 per demand, needs a SIL 3 function.

The incubator's cutout is called on only when the control loop fails toward heating, and while the loop works the cutout waits (Chapter 5). As long as the loop fails no more than once a year, the cutout is in low-demand mode and its target is a PFDavg. The machinery standard of Chapter 23 is ISO 13849-1:2023. It applies to the high-demand and continuous modes and points to IEC 61508 for low demand, and the performance levels it sets are bands of dangerous failures per hour.

The incubator's cutout by LOPA and by risk graph

The protective channel of Chapter 4 gets its level from a LOPA of its own. The initiating events in that LOPA are the failures that Chapter 5 lists as demands on the channel: a control thermistor reading low and a heater driver stuck on. The alarm at the cot side shows what the controller sees (Chapter 4). It stays silent when the control thermistor reads low, so by Chapter 7's rule it earns no credit against that cause, and the example gives it none against the other. The consequence is air heated past the cutout's limit with an infant inside. The example counts it as able to kill, which the infant's death from heat stroke in Chapter 1 shows to be possible.

The rate of the initiating events is borrowed. The process tables of Chapter 7 put a control loop's failure at about once in 10 years, and the example uses that value for all the causes together, as a stand-in. The target is 1 in 10,000 a year for each incubator, the most that HSE's framework tolerates for a member of the public from all the hazards of the activity that reach that person (Chapter 6). That figure is a limit rather than a goal, since a risk above the broadly acceptable 1 in a million must still be reduced as far as is reasonably practicable.

The example gives the whole of the limit to overheating, as a second stand-in, whereas Chapter 6 sets the target for a single scenario below the limit. A frequency per incubator also overstates the risk to any one infant, who spends only part of a year inside. The level that follows is this book's reading of a device in IEC 61508's terms. The device standards themselves state their requirements in other terms and use no SIL (Chapter 25).

Solved example: the incubator's cutout given its level by LOPA

The causes of a demand together come about 0.1 times a year. The alarm at the cot side gets a factor of 1. The enabling condition, an infant inside, is taken as 1, and so is the conditional modifier, harm once the air overheats. Without the cutout the air overheats with an infant inside 0.1 × 1 × 1 × 1 = 0.1 times a year, against a target of 0.0001. The risk reduction factor is 0.1 ÷ 0.0001 = 1,000, so the protective channel may fail on no more than 1 demand in 1,000. A factor of exactly 1,000 is the top of the SIL 2 range. A SIL 2 function meets it only at the best edge of its band, and a SIL 3 function meets it throughout its band. As for any factor on a boundary, the cutout therefore needs SIL 3, in low-demand mode, on these stand-in inputs. If the alarm had a sensor of its own, and a nurse could answer it within the time the air's climb allows, the 0.1 that Chapter 7's tables give an operator answering an alarm would apply to every cause (Chapter 9). The frequency would fall to 0.01 a year, the factor to 100 and the level to SIL 2. The sensor the alarm reads is worth one integrity level.

A risk graph reaches a level without a worksheet, through four questions about the hazard, each answered by choosing a class. The first two ask for the consequence C, in classes C1 to C4, and for the exposure F, in classes F1 and F2, which covers how often and how long someone is in the hazardous zone. The other two ask for P, the possibility of failing to avoid the hazardous event, in classes P1 and P2, and for W, the probability of the unwanted occurrence without the function, in classes W1 to W3. In each the higher class is the worse, and the answers lead along one path of a tree to a level. These are the parameters of the risk graph in Part 5 of IEC 61508.

The classes are words, and the graph gives a sound answer only when each stands for a number fixed against the tolerable frequency. De Salis, an engineer at the Milford Haven refinery, worked such a calibration in a 2014 conference paper. In his calibration C2 is one death, C1 a tenth of one, C3 is 10 deaths and C4 100. F1 counts as 0.1 and means a chance below 1 in 10 that someone is in the zone; F2 counts as 1. P1 counts as 0.1 and P2 as 1. With W as the demand rate a year, the four values multiplied along a path give the expected deaths a year without the function. Dividing the expected deaths by the tolerable frequency gives the risk reduction factor. A graph calibrated this way is a LOPA asked as four questions, each answered in tenfold steps.

For the incubator the path runs through C2, one death, as in the LOPA, and through F2, since an incubator in use holds an infant. The path then runs through P2, since an alarm that sees what the controller sees gives no warning when the control thermistor reads low, and through W at 0.1 a year. The product is 1 × 1 × 1 × 0.1 = 0.1 deaths a year, 1,000 times the target, so the graph asks for SIL 3. The graph and the LOPA agree because they multiply the same numbers. A nurse able to avoid the harm moves P to P1 and the level to SIL 2, as the alarm with its own sensor did in the LOPA: each answer moved by one class moves the level by one.

17 — A calibrated risk graph, traced for the incubator
RISK REDUCTION FACTOR = C × F × P × W / (1 IN 10,000 A YEAR) C1 0.1 death F1 0.1 P1 0.1 P2 1 F2 1 P1 0.1 P2 1 C2 1 death F1 0.1 P1 0.1 P2 1 F2 1 P1 0.1 P2 1 C3 10 deaths F1 0.1 P1 0.1 P2 1 F2 1 P1 0.1 P2 1 C4 100 deaths F1 0.1 P1 0.1 P2 1 F2 1 P1 0.1 P2 1 W1 0.01 A YEAR W2 0.1 A YEAR W3 1 A YEAR none none SIL 1 none SIL 1 SIL 2 none SIL 1 SIL 2 SIL 1 SIL 2 SIL 3 none SIL 1 SIL 2 SIL 1 SIL 2 SIL 3 SIL 1 SIL 2 SIL 3 SIL 2 SIL 3 SIL 4 SIL 1 SIL 2 SIL 3 SIL 2 SIL 3 SIL 4 SIL 2 SIL 3 SIL 4 SIL 3 SIL 4 beyond SIL 4 SIL 2 SIL 3 SIL 4 SIL 3 SIL 4 beyond SIL 4 SIL 3 SIL 4 beyond SIL 4 SIL 4 beyond SIL 4 beyond SIL 4 a nurse able to avoid the harm the incubator: one death, an infant always inside, no warning, 0.1 a year Schematic. C, F and P as de Salis calibrated them (2014 conference paper); W taken as the demand rate in tenfold steps; tolerable frequency 1 in 10,000 a year, as in the chapter's solved example. Computed, not measured.
Operator and alarmSafety functionFocal detail
Plate 17 — Calibrated in numbers, a risk graph multiplies consequence, exposure, avoidance and demand rate and divides by the tolerable frequency, as a LOPA does, so each class one step worse raises the level by one. The incubator's path ends at SIL 3, the level its LOPA gave, and at SIL 2 if a nurse can avoid the harm.

The same sensitivity makes the wording of the classes dangerous. A team that picks classes by their definitions, without the numbers behind them, can shift a level by one or two steps without noticing. Part 3 of IEC 61511 offers its risk graphs as illustrations of techniques and says that the graphs are not suitable for use as shown, as de Salis notes. He also found the standards' example graph mathematically wrong when its classes take conventional values. Working one path of a calibrated graph as a LOPA, as for the incubator, checks the calibration.

Why the top band is rare

At SIL 4 a function in low-demand mode may fail on fewer than one demand in 10,000. The random share of that probability can in principle be driven down with channels that back each other up and are tested often. The level sets how much such redundancy the architecture must have and how strictly the function must be developed (Chapters 13 and 15). A cause in the hardware that reaches all channels at once is counted in the random share only through an estimate, Chapter 14's β factor, a fraction of each channel's failure rate. The systematic share is harder to drive down. It comes from a requirement written wrong, or from a design fault that every channel carries, such as a software fault that every channel runs (Chapter 14). No failure rate counts such failures, so their rarity at that level rests on how the function was made, not on a number.

A regulator draws the consequence in plain terms. In its internal technical guidance on instrumented protection for offshore pipeline risers, dated 2022, HSE says that a proposal for SIL 4 "should be resisted strongly as there is no precedent", that levels above SIL 3 cannot be assured in practice, and that HSE prefers inherent safety. In the process sector, the first edition of IEC 61511 already asked that functions of high integrity be avoided where reasonably practicable. Its 2016 edition, IEC 61511-1:2016, gives guidance on techniques for avoiding them.

The levels asked for in practice are low. In a 2019 conference paper, Keswick, a principal of a consultancy, drew on the functional safety assessments he had carried out. He reported that most non-nuclear process functions need SIL 1 or SIL 2 and very few need SIL 3, and that a SIL 4 requirement typically points to a problem in setting the tolerable risk. In the incubator's case, a target 10 times stricter, 1 in 100,000 a year, would have asked the cutout for SIL 4. The alarm on its own sensor would remove that need by taking one level off. For tanks such as Tank 912, the guidance written after Buncefield asks for overfill prevention of at least SIL 1, its level set by a risk assessment (Chapter 22).

One scale in many standards

The idea of a band set from a gap recurs in other sectors under other names. Road vehicles grade their requirements as automotive safety integrity levels, ASIL A to ASIL D, set from the severity of the harm, the exposure to the situation in which it can occur and its controllability (Chapter 24). Machinery grades them as performance levels, PL a to PL e, set from severity, the frequency or duration of exposure and the possibility of avoiding the harm (Chapter 23). Both, like the SIL, are bands that a risk assessment sets and the design must then meet.

One of the objectives that IEC 61508 states for itself is to help such sector standards to be written, and IEC 61511 describes itself as a process sector implementation of IEC 61508:2010. IEC 61508 is in revision. The 2025 annual report of the Swiss national committee, published in 2026, records the final draft of the standard's third edition, the FDIS, as available for all seven parts. A standards reseller's catalog shows the formal vote on the European version of Part 1 circulated on 2 October 2026. The bands in this chapter are those of the 2010 edition, which is in force.

Set the level from the shortfall

For each safety function, record the frequency of its consequence with the credited layers, the tolerable frequency and where each number comes from, and divide the first frequency by the second. Choose the mode from the demand rate, and state the target as a PFDavg or a PFH to match. Where the factor falls on a boundary, take the level that meets it throughout its band. Calibrate any risk graph in numbers against the same tolerable frequency, and check one of its paths against a LOPA. Treat a SIL 4 result as a reason to revisit the target, the credits and the design. For a device such as the incubator, give the alarm its own sensor before raising the cutout's level. Write the level, the mode and the target into the safety requirements specification (Chapter 17).

+ What this chapter established
  • The risk reduction factor is the frequency of the consequence with the credited layers divided by the tolerable frequency, and the new function may fail on no more than one demand in that many.
  • IEC 61508:2010 sets four tenfold bands, SIL 1 to SIL 4: a PFDavg from below 1 in 10 down to 1 in 100,000 in low-demand mode, and a PFH from below 1 in 100,000 hours down to 1 in a billion in high-demand and continuous modes.
  • On the chapter's stand-in demand rate and target, the incubator's cutout needs SIL 3 by a LOPA and by a calibrated risk graph while the alarm at the cot side reads the control thermistor. It needs SIL 2 once the alarm has its own sensor and a nurse able to answer it in time. The device standards state their requirements in other terms and use no SIL (Chapter 25).
  • SIL 4 is rare because no failure rate shows the systematic share to be that rare, and HSE's internal guidance for offshore pipeline risers holds that levels above SIL 3 cannot be assured in practice. The same banded idea appears as ASIL in road vehicles and as performance levels in machinery.