+ Guide · Functional safety
One fault away.
How one part fails and which way the failure falls, how a safety function still brings a system to a safe state, how rarely it may fail and how that figure is counted and earned, and how five sectors and the law in Europe, the UK, the US and India apply the method.
+ The central question
If any part of a system can fail, how can the system still bring itself to a safe state in time, and how rarely may that protection fail before the risk that remains is accepted?
Contents.
+ Start
—A reading that held still
—Before we start
+ Part I · Failure
01What fails, exactlyWhat has gone wrong when a part "fails", and why does the chain from a fault to harm matter?
02Which way it fallsWhy are failures sorted by what they do to the hazard, and which of them can a system see?
03Two kinds of causeWhy can a resistor be given a failure rate when a line of code cannot?
04One job, from sensing to actingWhat must happen, from the sensor to the final element, to protect against one hazard, and how fast?
+ Part II · Risk
05From a hazard to a numberHow does a hazard become a risk that can be compared with another?
06Where the line is drawnWho decides how much risk is acceptable, and on what grounds?
07Barriers in seriesWhen do separate barriers multiply, and what makes a barrier count as one?
08From the gap to a levelHow is the gap between the risk there is and the risk accepted turned into an integrity level?
09A person in the loopWhen can someone answering an alarm count as protection, and why so rarely above SIL 1?
+ Part III · Numbers
10Failures per hourWhat does a failure rate measure, and where do the numbers come from?
11Failures nobody seesWhy does a hidden failure make the test interval part of the design?
12A system that checks itselfHow does a system find its own failures, and what is diagnostic coverage worth?
13Two channels, three channelsHow do 1oo2 and 2oo3 trade a missed trip against a false one?
14One cause, both channelsWhy do two identical channels fail together far more often than chance allows?
+ Part IV · Systematic failure
15Earned by methodIf systematic failures have no rate, how does a standard ask for confidence in them?
16Code without a failure rateWhat does a standard ask of safety software, and what does each requirement prevent?
+ Part V · The lifecycle
17Owned from start to endWhy is functional safety organized as a lifecycle, and who owns each step?
18FMEA, FMEDA, fault treesHow do engineers find the single failure, or the pair, that leads to harm?
19Checked by someone elseHow does a project show the function was built as specified and is enough for the hazard, and how independent must the checker be?
20Integrity for a working lifeHow is a safety function kept at its integrity for its whole working life?
21What a certificate promisesWhat does a SIL certificate or a safety manual promise, and what is left to the buyer?
+ Part VI · Sectors
22Buncefield, barrier by barrierWith the whole method in hand, which barriers failed at Buncefield, and what does IEC 61511 now ask of an overfill function?
23Guards, stops and robot cellsHow do ISO 13849-1 and IEC 62061 apply the method to a guard, a stop and a robot cell?
24A function the driver also controlsHow is an integrity level set for a function a driver can override, and what about hazards with no fault at all?
25Single fault, risk and softwareWhere does a device's safety sit between IEC 60601-1, ISO 14971 and IEC 62304, and why do the device standards use no SIL?
26One sensor, one software functionHow do aviation and defense set integrity, and what did the 737 MAX show about a function fed by one sensor?
+ Part VII · The field in 2026
27Makers and assessors, India includedWho makes safety controllers, safety silicon and field devices, and who certifies them?
+ Part VIII · Quality and regulation, as of November 2026
28From directives to dutiesHow does European and UK law reach the standards, from machines to major hazard sites?
29Rules that point to good practiceHow do US agencies tie the standards to their rules, for plants, devices, vehicles and aircraft?
30Rules after JaipurHow do India's regulators tie the standards to their rules, and what changed after the Jaipur depot fire of 2009?
+ Back matter
§Lessons
§Glossary
§Sources
§ PDF edition
Take the PDF with you.
Reading online needs no sign-up. For the PDF edition, laid out for print and offline reading, tell us where to send it and we will email you.
Sent
Check your inbox.
The download link is on its way to your email. If it has not arrived in a few minutes, check your spam folder or write to info@unplex.tech.
Preview only — nothing was sent
Let's Talk