+ Part II · Risk

How safe is safe enough.

No design removes risk; a design only lowers it, and every chapter of this part asks how far. A safety function makes harm rarer but never impossible, so how rare it must make the harm is decided before the function is designed. Chapter 5 turns a hazard into a frequency and a consequence that can be compared with another hazard's. Chapter 6 asks who draws the line between a risk that is tolerated and one that is not, and on what grounds. Chapter 7 counts the barriers already standing between a hazard and harm, and Chapter 8 turns the gap that remains into an integrity level. Chapter 9 asks when a person answering an alarm can count as one of the barriers.

05 — Hazard and risk

From a hazard to a number.

+ The questionHow does a hazard become a risk that can be compared with another?

A guide word for every line

A hazard is a potential source of harm, such as the petrol in a storage tank or the heater of Chapter 4's incubator. It harms no one while the process does what it was designed to do. A hazard study therefore looks for the departures from that design intent that would release the hazard. The study begins with a team, a drawing and a set of guide words applied to every line on the drawing. The team brings together people who designed the plant and people who will run it, and the drawing shows the plant's pipes, vessels, valves and instruments.

The method is the hazard and operability study, or HAZOP, and IEC 61882:2016 is its international application guide. The team first states the design intent of each line: the flow, pressure, temperature or level that the line should have. It then applies guide words to that intent: No, More, Less, As Well As, Part Of, Reverse and Other Than. Four more words cover timing and order: Early, Late, Before and After. "More" applied to the level in a tank gives a level higher than intended.

Each such departure from the intent is a deviation. The study asks of every deviation what could cause it, what would follow, and which safeguards already stand in the way. A team cannot picture every way a plant can go wrong, but it can ask the same questions of every line, so the drawing, not the team's memory, sets how complete the search is.

A what-if review asks open questions instead, such as what follows if a valve is left open, so it takes less time than a HAZOP, is less detailed, and depends more on the experience of the team. A failure modes and effects analysis, or FMEA, starts from the parts. It takes each part's failure modes, such as open, short, drift or stuck in Chapter 1's terms, and follows each effect up to the function. A HAZOP finds deviations that no single part explains, such as a tank filled from the wrong line, and an FMEA finds failures that no deviation names, such as a sensor drifting slowly within its range. Chapter 18 describes FMEA in full.

One line on Tank 912

A HAZOP records each deviation as a row of a table. The row below is an illustration written for this chapter. The line it studies is the pipeline that fills Tank 912 with petrol, and the design intent is to deliver a batch and stop below the tank's maximum working level.

Guide wordDeviationCausesConsequencesSafeguards
More (level)Level above the intended fillSpace left in the tank miscalculated; batch sent to the wrong tank; gauge stops reading; transfer not stoppedPetrol spills from the vents in the tank roof and forms a vapor cloud, which can igniteThe gauge's three level alarms; the independent high-level switch, which closes the valves on the incoming lines and sounds an alarm

The row already shows a safeguard that shares a part with a cause, the problem that Chapter 7 develops. The gauge appears in the row twice. It is a cause, since a gauge that stops reading lets a fill continue unseen, and it is the source of three of the four safeguards, since the three alarms are set on the gauge's own reading. When a cause disables a safeguard, that safeguard has nothing to act on, so against a stuck gauge only the switch stands in the way. The opening describes the night on which the gauge stuck and the switch could not act, and Chapter 11 explains why the switch could not.

How often, and how bad

A HAZOP row says nothing of how likely the deviation is or how bad its worst outcome would be, so a study of a whole depot ends with many rows and no order among them. The consequence is the harm a deviation can lead to, rated by its severity. A study of a process plant usually counts it as the number of people who could be killed, because an ignited cloud of vapor can reach people far beyond the tank. For the incubator the person exposed is one infant, and the severity runs from a burn to death, the outcome of the case told in Chapter 1.

The frequency is how often the deviation leads to that harm, counted per year. Incubators have overheated from several causes. In 2008 one maker recalled incubators whose heater power board might not regulate the temperature properly. Foil laid over the air vents let the air beneath it heat until an infant's fingers were burned. In skin mode an infant became febrile because the skin probe was not attached, as the maker reported (Chapter 25). The recall and the reports of adverse events name causes that makers and users have described. They do not say how often those causes occur, because they count reports and not the incubators in use. Each report of an adverse event is also an unverified allegation. The frequency comes instead from the failure rates of parts (Chapter 10), combined by the methods of Chapter 18.

Risk combines the two measures, and to compare hazards the combination must be a single number. The natural choice is the product of frequency and consequence. Averaged over a long time, a hazard expected to kill one person once in 10,000 years causes 1 in 10,000 deaths a year, and one expected to kill 10 people once in 100,000 years causes the same. That product is the expected harm, and it puts a frequent small harm and a rare large one on one scale. ISO 14971:2019, the standard for risk management of medical devices, defines risk as the combination of the probability of occurrence of harm and the severity of that harm. The product is one way of forming that combination, and Chapter 25 follows the standard through risk control and the weighing of benefits against residual risk.

10 — Risk as frequency times consequence
0 1 2 4 6 8 10 0 2 4 6 8 10 DEATHS IN ONE ACCIDENT TIMES IN 100,000 YEARS 1 DEATH, ONCE IN 10,000 YEARS 10 DEATHS, ONCE IN 100,000 YEARS same area: 1 in 10,000 deaths a year Schematic: two hypothetical hazards. Height × width = expected deaths.
Dangerous failureFocal detail
Plate 10 — Frequency times consequence is the area of each rectangle, the expected harm. A frequent small harm and a rare large one can have the same area, here 1 in 10,000 deaths a year, though the accidents behind them differ.
Equal products can stand for very different accidents

The product treats the two hazards above exactly alike, because it measures the average harm and not whether the harm comes in frequent small accidents or in rare large ones. An equal product therefore does not make two hazards equally acceptable. Regulators of major hazards in the UK judge accidents that kill many people at once by a separate test, and the Netherlands applied a line of its own until 2024. Chapter 6 sets out both.

A matrix sorts risks into cells

Instead of computing the product for each row, a study can place the row on a risk matrix, a tool used in process safety to rate and rank the risks of hazardous events. The matrix is a grid with bands of frequency down one side and bands of consequence along the other, and each cell carries a verdict, often shown as a color. Choosing a band for each measure takes little time and needs no exact frequency, which a team often lacks, so a matrix orders a long study quickly and the same way every time. Its weakness is the width of the bands, because a cell holds every risk that falls inside it, however far apart those risks are. In 2009 the Process Safety Leadership Group, or PSLG, issued guidance for fuel storage sites that sets out such a grid of risk criteria. The grid has frequency in tenfold bands and the number of deaths in groups of one, 2 to 10, and 11 to 50.

Solved example: three risks on one grid

The example uses the cell of that layout for frequencies from 1 in 100,000 to 1 in 10,000 a year and 2 to 10 deaths. Risk A kills 2 people a little more often than once in 100,000 years, just inside the cell's lower edge, so its expected harm is about 2 ÷ 100,000, or 2 in 100,000 deaths a year. Risk B kills 10 people once in 10,000 years, at the cell's upper corner, and 10 ÷ 10,000 is 1 in 1,000 deaths a year, or 100 in 100,000. B is therefore 50 times A: a factor of 10 across the frequency band times a factor of 5 across the group of deaths. Yet the two share one cell and one verdict. Risk C kills 10 people a little less often than once in 100,000 years, so it falls in the band below, at about 10 in 100,000 deaths a year, 5 times A. Wherever the two bands carry different verdicts, the grid rates C, the larger risk, below A.

In a mathematical analysis of risk matrices published in 2008, Cox found that typical matrices can correctly and unambiguously compare only a small fraction of randomly chosen pairs of hazards, for example fewer than one in 10. Cox also found that matrices can give the higher rating to the quantitatively smaller risk, as a grid would rate A above C wherever their two bands carried different verdicts. A matrix is weakest where frequency and severity run against each other, the frequent hazards minor and the rare ones severe, and for that case Cox called it "worse than useless". In a 2016 paper, Baybutt, the principal of a process safety consultancy, called the rating of a smaller risk above a larger one a ranking reversal error. The paper sets out how a matrix can be designed to avoid it.

11 — One cell can hold risks 50 times apart
DEATHS IN ONE ACCIDENT 1 DEATH 2 TO 10 DEATHS 11 TO 50 DEATHS FREQUENCY 1 IN 10,000 TO 1 IN 100,000 A YEAR 1 IN 100,000 TO 1 IN 1,000,000 1 IN 1,000,000 TO 1 IN 10,000,000 1 IN 10,000,000 TO 1 IN 100,000,000 A: 2 IN 100,000 A YEAR B: 100 IN 100,000 C: 10 IN 100,000 C IS 5 TIMES A, ONE BAND LOWER same cell: B is 50 times A Grid layout of the risk criteria in PSLG 2009, Appendix 2, Table 8: bands and groups only, cells without verdicts. A, B and C hypothetical; beside each, its risk in expected deaths a year.
Dangerous failureFocal detail
Plate 11 — One cell holds every risk inside its bands. B is 50 times A and shares its cell, and C, five times A, falls in the band below, so a matrix that gives the lower band a milder verdict rates the larger risk below the smaller.

A matrix therefore sorts risks without measuring them. It suits a study that must order many deviations quickly, but it misleads where a decision depends on a factor of 10. The choice of an integrity level is such a decision, since each level of Chapter 8 spans one tenfold step. For a hazard that needs a safety function, the study carries both measures forward as numbers, starting with how often the hazard will call on the function.

The initiating event and the demand rate

The chain from a hazard to harm starts with an initiating event, the smallest combination of failures or errors that sets an accident sequence going, such as a gauge that stops reading during a fill. Some sequences also need an enabling condition, a state that is neither a failure nor a protection but must be present, such as a batch large enough to overflow the tank. An initiating event that the process does not correct by itself makes a demand in Chapter 1's sense: an occasion on which a safety function must act.

The demand rate is how often such demands reach a safety function, counted per year. It is the frequency of the initiating events, multiplied by the share of them that meet their enabling conditions and by the share that pass every barrier acting earlier. For the incubator's cutout, a demand comes when the air reaches the cutout's limit because the control loop has failed to stop the rise in air temperature, whether from a control sensor reading low or from a heater driver stuck on. While the loop works, the cutout is never called on. It stays idle, the condition in which the hidden failures of Chapter 11 accumulate.

The demand rate depends on how a process is run as well as on how it is built. At Buncefield the level sometimes passed the 'high' alarm, less often rose to 'high-high', and on occasions went beyond even that, as the regulators who investigated the explosion found. The supervisors used the alarms to control the filling, the practice that the opening describes. The alarms were meant for the rare fill that continues past its intended level, but they were answering demands as part of routine work. Each fill taken beyond 'high-high' came nearer to the level at which only the switch stood in the way.

The demand rate carries the hazard's frequency into the design of the function. A basic control loop in a process plant is typically taken to fail about once in 10 years, a value from the tables that Chapter 7 uses. A function that stands behind such a loop can be called on about that often. If that function fails on one demand in 100, the event it exists to prevent occurs about once in 1,000 years: the frequency of that event is the demand rate multiplied by the probability that the function fails on a demand. How often harm follows the event depends on what comes after it, such as ignition and the presence of people, and Chapter 7 counts those factors.

The demand rate also decides which number describes the function. For a function called on rarely, what matters is the chance that it has failed when the call comes, the average of Chapter 11. For one called on often, every dangerous failure soon meets a demand, so what matters is how often such failures occur. Chapter 8 sorts functions by their demand rate into modes of operation.

Carry numbers, not cells, from the hazard study to the function

Search from both sides: apply guide words to the process or to the device's functions, and follow each part's failure modes (Chapter 18). For every deviation that a safety function will answer, record its initiating events, enabling conditions and consequence, and an estimate of each frequency with its source. Mark every safeguard that shares a part with a cause, as the gauge's alarms shared the gauge. Use a matrix to order the study, then carry a number into each safety function's demand rate and its requirements specification (Chapter 17). For a device such as the incubator, the same record belongs in the risk management file that Chapter 25 describes.

+ What this chapter established
  • A hazard study finds hazards by applying guide words to every line of a design, or by following each part's failure modes, and records each deviation with its causes, consequences and safeguards.
  • Risk combines how often a hazard leads to harm with how severe the harm is, and their product, the expected harm, puts frequent small harms and rare large ones on one scale.
  • A risk matrix sorts risks quickly, but one cell can hold risks 50 times apart, and where two bands carry different verdicts the larger of two risks can be rated below the smaller.
  • The demand rate is how often demands reach a safety function. Multiplied by the probability that the function fails on a demand, it gives the frequency of the event the function exists to prevent, and it decides which number describes the function.