+ Opening

Arrivals in the first three hours.

Each of the 786 patients had come to an emergency department with chest pain, or with another symptom that might have meant a heart attack, and each gave a tube of blood soon after arriving. The study that collected those tubes was coordinated from University Hospital Basel in Switzerland and enrolled patients between April 2006 and April 2008. The blood was not used to decide anyone's care. The plasma was frozen at minus 80 °C and measured later, in two batches in a core laboratory, by staff who did not know which patients had been ill.

The 718 samples that could be run on all five tests were measured for cardiac troponin, a protein of heart muscle that leaks into the blood when heart cells die. One test was the standard troponin T assay in routine use at the time. The other four were newer and more sensitive, made by three companies. Two cardiologists decided who had in fact had a heart attack. They worked independently through each patient's records from arrival to 60 days later, without seeing the results of the four new tests. They counted 123 patients, 17 percent of the 718.

The researchers then asked how well each test separated the patients who had had a heart attack from those who had not, using the single sample taken on arrival. They scored the separation as an area under a curve, a number that is 1.0 when a test separates two groups perfectly and 0.5 when it does no better than tossing a coin. Across all patients the standard assay scored 0.90 and the four sensitive assays 0.95 to 0.96. For patients who had arrived within three hours of the start of their pain, the gap opened: the standard assay scored 0.76, and the sensitive assays 0.92 to 0.94.

The sensitive assays had not found a new marker. They measured cardiac troponin, T or I, released by the same damaged muscle, at concentrations that the standard assay could not tell apart from none. The paper appeared in the New England Journal of Medicine on 27 August 2009, beside a German study of 1,818 patients at Mainz, Koblenz and Hamburg that reached the same conclusion with a sensitive troponin I assay.

What followed took years. The sensitive troponin T assay was launched in Britain and Ireland in late 2009. In 2015 the European Society of Cardiology recommended ruling a heart attack in or out from two samples taken an hour apart, with cut-offs set separately for each assay. In the United States the first such assay was cleared by the Food and Drug Administration on 18 January 2017, and the agency's review drew part of its clinical evidence from the same 718 patients of the Basel-coordinated study. The cleared test carried the name Troponin T Gen 5. A trade report stated that the agency had asked its maker to call it "next generation" rather than "high-sensitivity". Between the old assay and the new, the protein, the patients and even the antibodies' target stayed the same. What changed was how few molecules of troponin a test could tell apart from none.

Created with Claude (Anthropic).
Educational reference material, not engineering, regulatory or clinical advice. Product and company names referenced are the property of their respective owners.