§ Lessons
Lessons.
The chapters leave thirteen working rules for anyone who reads, funds, buys or reports on quantum computers. After each rule come the chapters that explain why it holds.
- Ask how the cost grows, not how many seconds it took. A ratio of run times measures the classical method of its day. Whether an advantage is real depends on how each cost grows with the size of the problem (Chapters 1, 9 and 11).
- Treat every quantum output as one sample. Each run returns a single 0 or 1 per qubit, drawn from odds the machine prepared. Any probability quoted from a machine was therefore estimated from many runs and carries their spread (Chapters 2 and 3).
- Look for hidden structure before choosing a quantum method. Large speedups come from interference that cancels wrong answers, and that interference needs structure such as a period. Unstructured search gains only a square-root speedup, which rarely survives the cost of error correction (Chapters 6, 7 and 9).
- Count the data as well as the arithmetic. A quantum computer loads and reads data slowly, so problems dominated by input and output gain little, however fast the arithmetic inside it is (Chapter 9).
- Set every claim against the best classical method on the best hardware. Sampling claims, chemistry benchmarks and the factoring record all moved when classical methods improved, sometimes within weeks of the claim (Chapters 1, 10, 11 and 21).
- Quote errors per operation, then multiply by the operations needed. A gate that errs once in a thousand is good hardware but useless for a computation of billions of steps. For RSA-2048, error correction must close a gap of about 10¹² between the physical and the protected error (Chapters 4 and 13).
- Read a threshold as a slope. Below threshold, each increase of two in code distance divides the error by Λ. The size of Λ, more than the crossing of the threshold itself, sets how many physical qubits each protected qubit costs (Chapters 14, 15 and 16).
- Ask how a logical qubit was counted. Code distance, real-time correction, discarded runs and the logical error per operation decide what a count means. Counts from codes that only detect errors measure something else (Chapters 16 and 21).
- Budget the instrument, not only the chip. Refrigerator stages, wiring, amplifiers, control electronics and the decoder each limit how many qubits can work together and how quickly corrections arrive (Chapters 17 and 18).
- Compare platforms by cycle time and losses as well as by fidelity. Two-qubit gates are now near 99.9 % on ions, atoms and superconducting chips. What separates the platforms is the time for one error-correction cycle and the qubits lost in it (Chapters 19 and 21).
- Restate every resource estimate as qubits, hours and assumptions. Error rate, cycle time, connectivity and reaction time decide the headline number. On the hardware assumed since 2019, the bill for RSA-2048 has stayed near 10⁸ qubit-hours (Chapter 22).
- Convert a roadmap into the units of the bill. Logical qubits, error per logical operation and operations sustained can be set against a known problem, while a date or a count of physical qubits cannot (Chapters 20 and 22).
- Label every figure by where it was measured and who reported it. A single pair of qubits and a whole-chip median are different kinds of evidence, and so are a peer-reviewed paper and a company release. This guide marks which is which (Chapters 20 and 21).
Let's Talk