+ Before we start

Before we start.

Landauer's objection did not deny that the algorithm was correct. It said that a correct answer would cost something no one knew how to pay. That cost, and what it buys, is the subject here: what does it cost to get one reliable answer from a quantum computer, and for which problems is that answer worth the cost?

The answer has two halves, and the chapters take them in order. Some problems have a hidden structure, such as the period of a repeating sequence or the behavior of electrons in a molecule. For that small class, a quantum computer can arrange for wrong answers to cancel and the right one to reinforce, and so reach an answer in far fewer steps than any known ordinary method. For most problems, sorting a list or running a spreadsheet among them, it offers nothing.

The price is reliability. A quantum computer holds its information in qubits, physical systems with two levels that stand for 0 and 1, which Chapter 2 describes. The best physical qubits err about once in a thousand operations, so a useful computation must be protected by error correction. Error correction spends many physical qubits on each reliable one, and it needs a refrigerator, a microwave signal chain and a fast classical computer around them. Classical, here and throughout the guide, means ordinary rather than quantum. In a 2025 preprint, Craig Gidney of Google Quantum AI puts the factoring of the 617-digit number known as RSA-2048 at just under a million physical qubits running for about five days. Designs posted as preprints in 2026 need fewer qubits because they assume different hardware, with links between distant qubits or atoms that move, and they run for a day to about three months. The guide states this price in qubits, hours and error rates, not in money. The machines that ran error correction in 2026 hold hundreds of physical qubits, not hundreds of thousands. As of October 2026, no quantum computer has shown an advantage that is both useful and classically verifiable (Chapter 11).

A quantum computer never shows its state. Each run returns one sample, and every algorithm is a way of making that sample worth having. Reading a qubit gives a plain 0 or 1, drawn at random from odds the machine has prepared. The state the machine holds before that reading cannot be read without changing it. Every claim in the chapters ahead comes down to how good that one sample is and how many runs it took to get it, whether the claim is about speed, about errors or about a company's latest processor.

Two cases recur. The first is RSA-2048 and the machine needed to factor it, as estimated from 2003 to 2026. The estimates fell from about a billion qubits in 2012 to under a million in 2025, but on the same hardware assumptions the product of qubits and hours has fallen by only about a third since 2019. The second case is Willow, a 105-qubit chip from Google Quantum AI. In 2024 Willow kept a qubit's state under error correction, and the errors of that quantum memory fell by more than half each time it was made larger. The chapters build from one qubit to that chip, and from the chip to the bill.

How to read this guide

The 22 chapters form one sequence in eight parts. Readers who fund, buy or report on quantum computers can start from the Lessons at the back, the green In practice boxes and Chapter 22, which adds up the bill. Each chapter opens with the question left open by the chapter before it and contains at least one solved example worked with real numbers. Plates, the guide's illustrations, are numbered on their own, so any one can be cited by itself. Four kinds of box recur:

Insight or solved example

Blue edge. Carries the structural point of a section, or a calculation worked once with real values and stated assumptions.

Caution

Orange edge. Names a common misreading, a trap, or the limit of a claim.

In practice

Green edge. Maps the idea onto the reader's own work: specifying or evaluating hardware, reading a result or an announcement, or planning a project.

+ What this chapter established
  • Each chapter closes with what it established, in four lines.

The mathematics stays at arithmetic: powers, square roots, percentages and the remainder after a division. Quantum states appear as arrows, each with a length and a direction. Adding arrows is drawn rather than written as algebra, and the plates do the geometry. Large and small numbers are written with powers of ten, as in 10¹⁵ for a million billion, and a rate as "1 in 10¹⁵". Where a figure is a company's own claim, the text says so. The guide uses US spelling.

Inside the plates, color is a legend and never decoration. The quantum state, drawn as arrows, is violet; the pulses the machine sends in to control it are gold; noise and errors are magenta; information protected by error correction is teal. Classical bits, the readings and every number computed from them, are always blue, and one orange mark in each plate points at the detail that matters most. A key strip under every plate lists only the colors that plate uses.

The color key
THE THINGS THE PLATES TELL APART MEASUREMENT AND CONSTRUCTION AMPLITUDE the quantum state: arrows and their phases CONTROL PULSE what the machine sends in: microwave and laser pulses NOISE AND ERROR what scrambles the state: errors, heat and stray signals LOGICAL QUBIT information protected by error correction 0 1 1 0 READOUT measured bits, counts and classical results FOCAL DETAIL the one detail that matters: a single orange mark per plate GRAY hardware, construction, axes DASHED GRAY not measured, not yet built, company plans AMPLITUDE CONTROL PULSE READOUT FOCAL DETAIL each plate's key strip lists only the colors it uses
Key — The same color means the same thing in every plate: violet for the quantum state, gold for the pulses sent in, magenta for noise and error, teal for protected information, blue for what is read out, and one orange mark for the detail that matters.
The limits of this guide

This is a reference for understanding, not an engineering specification, investment advice or a security assessment. Machines, records, company positions and estimates are stated as of October 2026 and will date. Where a figure comes from a company about its own product, or from a paper whose authors work for that company, the text says so. Named companies and machines are examples of a principle, not recommendations.

Created with Claude (Anthropic).
Educational reference material, not engineering, regulatory or clinical advice. Product and company names referenced are the property of their respective owners.