19 — Other machines

Ions, atoms, photons and spins.

+ The questionTrapped ions, neutral atoms, photons and spins are all qubits. Do they hit the same limits?

The same definition, different instruments

Any two-level system that can be prepared, turned, entangled and read can serve as a qubit. The main alternatives to superconducting circuits meet that definition with different physics, and therefore with different instruments. Each trades the same quantities against each other: how accurately gates work, how fast they run, how long qubits hold their state, which qubits can interact, and how many can be built and controlled together. Through 2025 and 2026 the accuracy of the best two-qubit gates converged across the leading approaches, so the comparison now turns on speed, losses and scale.

51 — Five platforms on fidelity and speed
1 in 100 1 in 1,000 1 in 10,000 10 ns 100 ns 1 µs 10 µs 100 µs 1 ms 10 ms 100 ms TWO-QUBIT ERROR (LOG) Willow, superconducting: 0.33 %, 42 ns silicon spins: above 99 %, 212 ns neutral atoms (Harvard): 0.146 %, gates 0.25 µs moves: milliseconds Helios, ions: about 0.08 %, gate 70 µs average layer, with moves and cooling: 55 ms Oxford Ionics, one pair: 0.0084 %, 226 µs photons (PsiQuantum): fusion 0.78 % error, losses not counted; no time given, not plotted Willow, Helios, Oxford Ionics: company figures fidelities converge; clocks differ a millionfold TIME PER GATE, OR PER LAYER (LOG)
AmplitudeFocal detail
Plate 51 — By 2026 the best two-qubit gates on superconducting chips, ions and atoms all erred between about 1 in 10,000 and 1 in 300, but their operations take from tens of nanoseconds to tens of milliseconds, and that difference now separates them more than fidelity.

Trapped ions

A trapped-ion machine holds charged atoms in a vacuum above a chip, suspended by electric fields from electrodes on the chip's surface, and lasers or microwaves drive the ions. Every ion of a species is identical, so the qubits need none of the individual tuning that transmons do. Ions also hold their state for a long time: in a 2021 laboratory record, one ytterbium ion kept its phase for an estimated 5,500 seconds. Ions can be moved as well, so any qubit can be brought next to any other for a gate, which gives the machine full connectivity.

Quantinuum's Helios was announced in November 2025, and the company's staff described it in Nature in June 2026. Helios holds 98 barium-137 ions. Its two-qubit gates err about 8 times in 10,000, a fidelity of about 99.92 %. Its single-qubit gates err about 2.5 times in 100,000, and preparing and reading a qubit together err about 5 times in 10,000. A two-qubit gate takes about 70 microseconds, and because ions must be moved, cooled and gated in turn, an average layer of operations across the machine takes about 55 milliseconds.

In October 2025 a team at Oxford Ionics reported two-qubit gates above 99.99 % on one pair of ions. The gates were controlled electronically rather than with lasers, and each lasted about 226 microseconds. Oxford Ionics, a British company, was by then part of IonQ, a US company that builds trapped-ion machines. In September 2026 IonQ announced a 256-qubit system built on that electronic method, with deliveries planned for 2027. The announcement is a company claim, with no published fidelities for the full machine.

Neutral atoms

A neutral-atom machine holds uncharged atoms in tightly focused laser beams called optical tweezers, arranged in arrays that can be rearranged by moving the beams. Atoms interact when one is excited to a very large, high-energy state, a Rydberg state, in which its outer electron orbits far from the nucleus. Arrays have grown fast. In 2025 a Caltech team reported an array of over 6,100 atoms that kept their phase for 12.6 seconds, though the team reported no two-qubit gates on it. A Harvard and MIT team kept more than 3,000 atoms running for over two hours by reloading 300,000 atoms a second as others were lost.

Gate accuracy followed. In 2023 a Harvard team reached 99.5 % for two-qubit gates run on 60 atoms in parallel. In an April 2026 preprint, the same group reported 99.854 %, close to the best superconducting chips. The limits lie elsewhere: atoms are lost from their traps, and moving them takes milliseconds, so a cycle of error correction on atoms is far slower than on a superconducting chip. A June 2026 preprint reported trapping 11,000 atoms with a single patterned optical element, which is a scale figure for trapping, not for computing.

Photons

Photons hold their state almost indefinitely, because they barely interact with anything, and for the same reason they are hard to make interact with each other. Photonic machines therefore build entanglement through carefully timed measurements on pairs of photons, an approach PsiQuantum calls fusion-based computation. Their dominant error is not decoherence but loss: a photon that never arrives. In a 2025 Nature paper, PsiQuantum's staff reported qubit preparation and measurement at 99.98 % and fusion operations at 99.22 %, on chips made in a commercial foundry on 300-millimeter wafers. Those figures do not count lost photons. The design PsiQuantum analyzed in 2023 tolerated about a 10 % chance of loss in each fusion.

Xanadu is a Canadian company, and its staff described its Aurora machine in Nature in January 2025. Aurora linked 35 chips in a modular photonic machine but lost more than 95 % of photons along some of its optical paths, against a budget of about 1 % for fault tolerance. The paper's authors called Aurora a scale model that does not yet perform. Photon loss is the single number that decides whether the photonic route reaches error correction.

Spins in silicon

A spin qubit is a single electron held in a quantum dot, a region tens of nanometers across that electrodes define on a silicon chip. The electron's spin makes it a tiny magnet, and the qubit's 0 and 1 are that magnet pointing with or against an applied magnetic field. The approach borrows the manufacturing of the chip industry, and Intel's 12-dot Tunnel Falls chip of 2023 was made on 300-millimeter wafers.

In a 2025 Nature paper, a team including staff of Diraq and imec reported four devices made in an industrial foundry, with every operation above 99 %. Diraq is an Australian company that builds spin qubits, and imec is a Belgian research center for chip technology. In the team's preprint, two-qubit gates took about 212 nanoseconds. The devices' main remaining error came from traces of silicon-29, an isotope of silicon whose magnetic nuclei disturb the electron. Like transmons, spin qubits run in dilution refrigerators. In a related 2025 paper, a team ran a control chip of about 100,000 transistors at millikelvin temperatures beside spin qubits, and the chip degraded the qubits' single-qubit fidelity by only 0.07 %.

Topological qubits and annealers

Microsoft has pursued topological qubits, which would store information in exotic states of special superconducting wires and resist errors by their nature. The exotic states are called Majorana zero modes. In February 2025 Microsoft announced Majorana 1, a chip it described as holding eight topological qubits, together with a companion Nature paper on a measurement in such a device. According to a report by the American Physical Society, the paper's peer-review file stated that "the results in this manuscript do not represent evidence for the presence of Majorana zero modes."

In June 2026 Microsoft reported a second device, Majorana 2. In the company's preprint, the device had a parity lifetime of about 20 seconds. Parity here means whether part of the device holds an even or an odd number of electrons, the property in which such qubits would store information, and the parity lifetime is the average time before a stray particle switches it. In the same month Nature published a critique by Henry Legg of the University of St Andrews, who argued that the 2025 signals could arise from ordinary mechanisms, together with Microsoft's reply standing by its results. No two-qubit gate on such qubits had been reported as of October 2026.

D-Wave's machines are of a different kind. They are quantum annealers, which settle a large network of qubits toward a low-energy state rather than running sequences of gates. D-Wave's Advantage2 was released in May 2025, and by the company's count it has more than 4,400 qubits. Chapter 11 described the debate over D-Wave's 2025 claim.

Solved example: the clock behind a billion operations

A billion cycles of error correction on Willow, at 1.1 microseconds each, take about 1,100 seconds, or about 18 minutes. A billion layers of operations on Helios, at 55 milliseconds each, take 5.5 × 10⁷ seconds, about 1.7 years. The ions' gates are more accurate, and their connectivity can make codes more efficient, but the factor of 50,000 in clock time does not disappear. Fewer, better operations can close part of the gap, and the rest becomes run time. Neutral atoms sit between the two: their gates take about a quarter of a microsecond, but moving atoms between cycles takes milliseconds.

52 — A billion operations, by clock
1 s 1 min 1 h 1 day 1 year RUN TIME (LOG) WILLOW HELIOS 10⁹ cycles × 1.1 µs ≈ 1,100 s, about 18 minutes 10⁹ layers × 55 ms ≈ 5.5 × 10⁷ s, about 1.7 years a factor of 50,000 in run time neutral atoms between: fast gates, millisecond moves
AmplitudeFocal detail
Plate 52 — A billion error-correction cycles take about 18 minutes on Willow and a billion layers of operations about 1.7 years on Helios. More accurate gates and better connectivity can close part of that factor of 50,000; the rest becomes run time.
Compare machines by clock speed as well as fidelity

Two-qubit fidelities near 99.9 % now appear on superconducting, ion and atom machines, so fidelity alone no longer ranks them. Ask how long one cycle of error correction takes on each, including movement, cooling and readout, and multiply by the cycles a useful computation needs. Ask also what is lost per cycle: atoms from traps, photons from paths.

Ask for the time per error-correction cycle

For any platform, request the duration of one full cycle of the error-correcting code intended for it, the logical error per cycle achieved, and the qubits per logical qubit at that error. Those three numbers, not the physical qubit count or the best gate fidelity, convert into the run time and machine size of Chapter 22's bill.

+ What this chapter established
  • Trapped ions are identical by nature, hold their state for very long times and can be moved to connect any pair, but Helios's layers of operations take about 55 milliseconds.
  • Neutral atoms scale to arrays of thousands and reached 99.85 % two-qubit gates in 2026, with atom loss and slow movement as their limits.
  • Photonic machines hold qubits easily but lose photons, with Aurora losing over 95 % on some paths against a 1 % budget, and spin qubits borrow chip manufacturing, with foundry devices above 99 % in 2025.
  • Topological qubits remain disputed and annealers do not run sequences of gates, and across platforms the clock time of an error-correction cycle now separates machines more than gate fidelity does.
Created with Claude (Anthropic).
Educational reference material, not engineering, regulatory or clinical advice. Product and company names referenced are the property of their respective owners.