+ Part VIII · The bill
What one reliable answer costs.
Fewer than a million noisy qubits, running for less than a week: in a preprint of May 2025, that was the price Craig Gidney of Google Quantum AI put on factoring RSA-2048 with a machine whose qubits err about once in a thousand operations. Part VIII sets that price beside every earlier estimate and beside the machines and roadmaps of 2026, and from that comparison it answers the central question. Its single chapter adds up the bill, says what to watch, and closes the guide where it began, with Shor's weekend in April 1994.
What one reliable answer costs.
+ The questionWhat would it take to factor RSA-2048, and how far are the machines of 2026 from it?
Six estimates for one factorization
In August 2012, Austin Fowler, Matteo Mariantoni, John Martinis and Andrew Cleland put a number on the machine Shor's algorithm would need for a 2,000-bit number: about a billion physical qubits, running for about a day. Earlier counts had been of perfect qubits. Chapter 8 described a 2003 circuit by Stéphane Beauregard that needs only 4,099 of them for RSA-2048, and that figure is still quoted as if it were the size of a real machine. The 2012 estimate was an early and influential one. It included the cost of the surface code of Chapter 15, and most of its billion qubits went into factories for the magic states of Chapter 16. Every estimate since has reworked that design, and the table lists the main ones with what each assumes.
| Year | Estimate | Physical qubits | Run time | Main assumptions |
|---|---|---|---|---|
| 2003 | Beauregard | 4,099, all perfect | not estimated | no errors at all |
| 2012 | Fowler and colleagues | about 1 billion | about 27 hours | surface code; physical error about a tenth of threshold (0.06 to 0.1 %); 100 ns cycle |
| 2019 | Gidney and Ekerå | 20 million | 8 hours | surface code on a grid of neighbors; 0.1 %; 1 µs cycle; 10 µs to act on a decoded result |
| 2025 | Gidney | 897,864 | about 5 days | the same as 2019 |
| 2026 | Iceberg Quantum | about 94,000, or 381,000 | about a month, or one day | the same errors and cycle; codes needing long-range links |
| 2026 | Cain and colleagues | about 102,000 atoms | about 97 days | movable atoms; 0.1 %; 1 ms cycle |
From 2019 to 2025 the hardware assumptions did not change. The savings came from method. Gidney's 2025 design computes with approximate arithmetic, which tolerates small errors in intermediate results. It stores idle qubits in the yoked patches of Chapter 16, and it grows magic states by cultivation instead of distilling them. The design uses about 1,400 logical qubits at its peak. A factorization combines about nine runs of roughly half a day each, as the method's classical post-processing requires, and the nine runs together take about 6.5 billion Toffoli gates, about 7 × 10⁸ in each.
The two 2026 designs, both preprints, change the machine instead. Iceberg Quantum's design needs links between distant qubits within each processing block, and no superconducting chip yet offers such links at scale. The design by Cain and colleagues at Oratomic, Caltech and Berkeley moves atoms to make those links and pays with a clock a thousand times slower. The discrete logarithm of Chapter 7 came out cheaper still. In a March 2026 preprint, a Google-led team estimated what breaking the 256-bit elliptic-curve keys used by cryptocurrencies would need. It gave two versions, one with fewer than 1,200 logical qubits and 90 million Toffoli gates and one with fewer than 1,450 logical qubits and 70 million, each on fewer than half a million physical qubits running for under half an hour. The larger Toffoli count is about an eighth of the count in one run of Gidney's RSA-2048 design.
An estimate's headline number depends on the physical error rate, the cycle time, which qubits can interact and how quickly corrections arrive. A smaller count from a design that assumes long-range links or slower cycles is a different machine, not a cheaper version of the same one. A count of perfect qubits describes no machine at all.
Qubits fell, qubit-hours barely moved
The physical qubit count dropped a thousandfold between 2012 and 2025, while the run time rose from about a day to about five. Part of the rise comes from the cycle, because later designs assume a cycle ten times slower than the 2012 one. Another part comes from the factories: fewer of them feed the arithmetic, so each Toffoli gate waits longer for its magic states. Multiplying qubits by hours gives the quantity that tracks the real work, qubit-hours, which measure how many qubits must be kept protected and for how long.
The 2012 design needed a billion qubits for 26.7 hours, about 2.7 × 10¹⁰ qubit-hours, at a cycle ten times faster than later designs assumed. The 2019 design needed 20 million qubits for 8 hours, or 1.6 × 10⁸. The 2025 design needed 897,864 qubits for 119 hours, about 1.1 × 10⁸, which is only about a third less than in 2019, although the qubits fell twenty-two-fold. The 2026 atom design, 102,000 qubits for 97 days, comes to about 2.4 × 10⁸. Only the design that assumes long-range links moves the figure: 94,000 qubits for a month is about 6.8 × 10⁷, and 381,000 for a day about 9.1 × 10⁶.
The hardware assumed since 2019 is a grid of neighboring qubits that err once in a thousand operations, with a microsecond cycle. On that hardware the bill for RSA-2048 has stayed near 10⁸ qubit-hours for seven years. What changed was how the bill is paid: in qubits, which are hard to build, or in time, which an operator can usually wait out. So far the only route to a much smaller bill is a different machine, with longer-range links or better physical qubits, and both are still to be shown at scale.
The chemistry bill
The same accounting applies to the other problem this guide found worth the cost. In 2021 a Google-led team priced the smaller of the two FeMoco models of Chapter 10 at about 2,100 logical qubits and 5.3 billion Toffoli gates, running on about four million physical qubits for under four days. The team assumed the same 0.1 % error and microsecond cycle as Gidney's designs. With physical errors ten times lower, its estimate fell to about a million qubits for under two days. That 2021 bill is the same order as RSA-2048 on every axis, up to about 4 × 10⁸ qubit-hours.
Methods have since cut the gate count for the larger model about thirty-twofold. In 2025 the same group priced that model, on the same hardware assumptions, at about 4.5 million physical qubits for 8.6 hours. That comes to about 4 × 10⁷ qubit-hours, a tenth of the 2021 bill for the smaller model. But in a January 2026 preprint, a Caltech-led team reported that classical methods had reached chemical accuracy for the larger model's lowest energy, as Chapter 10 described. The chemistry case for a first machine therefore rests on harder questions than one ground-state energy, such as how a reaction proceeds step by step.
Against the machines of 2026
The table compares the bill for RSA-2048 with the best results reported by October 2026.
| Quantity | What the bill needs | Best shown by October 2026 | Gap |
|---|---|---|---|
| Protected qubits | about 1,400 | 1 at distance 7 with errors shown to fall as the code grows (Willow); 2 in a distance-6 code (Quantinuum) | about 700 to 1,400 |
| Error per protected qubit per cycle | 1 in 10¹⁵ | 7.7 in 10,000 (Willow, distance 7); 4.6 in 100,000 (Quantinuum, distance 6, two logical qubits) | 10¹¹ to 10¹² |
| Physical qubits | about 900,000, each erring about 0.1 % | 156 on IBM's cloud; 105 on Willow; 98 on Helios | about 6,000 in number |
| Continuous correction | about 5 days, decoded in real time | about one second, a million cycles, in a 2024 Google experiment | about 400,000 in duration |
The roadmaps of Chapter 20 close parts of the gap on paper. IBM's Starling in 2029 would have 200 logical qubits and 100 million operations. Quantinuum's Apollo, also planned for 2029, would have hundreds of logical qubits and about 10 billion operations before an error. Apollo's 10 billion operations are more than one run's 7 × 10⁸ Toffoli gates, but a Toffoli costs more than a typical operation, so the two counts do not compare directly. Apollo would also run on ions whose layers of operations take milliseconds, so it would need a design built around that slower clock, as Cain's group drew one for atoms. IonQ's plan goes furthest. It lists 1,600 logical qubits in 2028 and, by 2030, 80,000 that err less than once in 10¹² operations, at 25 physical qubits for each, a ratio not yet shown for codes of that strength. All three are company plans, to be read as Chapter 20's solved example reads them.
What to watch
The dates that will show whether those plans hold are public. The US Department of Energy's Quantum Genesis Q Competition asks for machines in 2028 with at least 100 logical qubits running hundreds of millions of fault-tolerant operations. It offers bonus pools at 150 and 200 logical qubits, and applications are due on 19 October 2026. DARPA's second-stage reviews of eleven companies run into late 2026 against its 2033 test. IBM plans Kookaburra, its first module with logical qubits, for 2026, and had not announced it as delivered by early October 2026. Quantinuum plans Sol, with about 100 logical qubits, for 2027, and QuEra plans Libra, with more than 256 at one error in a million operations, for 2028. Google's next milestone, a logical qubit erring once in a million cycles, was still unreached as of October 2026.
Four measurements will say more than any date. The first is a slope Λ above 2 sustained to distance 9 or beyond. The second is a logical error per operation for the T and Toffoli gates that algorithms need, not only for memory. The third is real-time decoding across many logical qubits at once. The fourth is a logical algorithm, corrected throughout, that ordinary computers cannot simulate. Cryptographers have not waited for any of these: new public-key methods designed to resist quantum attack already exist, and moving to them is a subject outside this guide.
For a resource estimate, write down the physical qubits, the run time, the physical error rate, the cycle time, the connectivity and the reaction time it assumes, and multiply qubits by hours. The reaction time is how quickly decoded results can steer the next operation. Compare two estimates only when their assumptions match. Set an estimate against a machine only once that machine has shown the error rate, cycle and connectivity the estimate takes for granted.
The rumor and the bill
In April 1994 Shor's result traveled from a seminar room to a telephone in a few days, and by the time the rumor arrived it was true. The machine it implied has taken longer, and in 2026 its price can be stated. On the best published design for the hardware assumed since 2019, one reliable answer to RSA-2048 costs about a million physical qubits, each erring no more than once in a thousand operations. On superconducting hardware that means chips held near 10 millikelvin and checked every microsecond for about five days, with a classical decoder keeping pace throughout. Designs that assume longer-range links or movable atoms need about a tenth of the qubits, and they pay in connectivity not yet built or in months of running.
That price is worth paying only for problems with hidden structure that ordinary computers cannot exploit. Factoring and discrete logarithms are such problems, and their answers can be checked at once. The simulation of molecules and materials whose electrons resist classical methods is another, with each benchmark rechecked as classical methods improve. For unstructured search, sorting and most problems dominated by data, a quantum computer does not pay for itself. As of October 2026 Google's best protected memory errs about 8 times in 10,000 cycles, and the largest RSA challenge number factored has 270 digits, factored by ordinary computers. The rumor ran ahead of the proof by days. The machine has run behind it for thirty-two years, and the distance is now a bill that can be itemized line by line.
- Estimates for factoring RSA-2048 fell from about a billion physical qubits in 2012 to 897,864 in 2025 and about 100,000 in 2026 designs that assume long-range links or movable atoms, each with different assumptions about the hardware.
- Measured in qubit-hours, the bill on the hardware assumed since 2019 stayed near 10⁸: qubits fell, and run time rose to about five days.
- Against the bill, the machines of 2026 are short by about 700 to 1,400 times in protected qubits, 10¹¹ to 10¹² in protected error and about 400,000 times in the duration of continuous correction, and four measurements, more than any date, will show whether that gap is closing.
- The cost is worth paying only for problems with hidden structure, such as factoring, discrete logarithms and hard problems in chemistry and materials, where each benchmark is rechecked as classical methods improve.
Let's Talk