A thing with two levels.
+ The questionWhat is a qubit, physically, and what do you get when you read one?
An atom made of wire
Google's Willow chip carries 105 transmons, small superconducting circuits patterned in aluminum on a chip and cooled to about a hundredth of a degree above absolute zero, where their metal carries electric current with no resistance at all. At the heart of each transmon is a Josephson junction, two thin films of superconducting metal separated by a barrier of their own oxide, through which pairs of electrons can tunnel. Tunneling means crossing a barrier that would stop the electrons in everyday physics. A circuit built around such a junction behaves in one important way like an atom. Its energy can take only certain values, called levels, and it moves between them by absorbing or giving up a definite amount of energy.
A qubit uses two such levels. In a transmon, the lowest level is called 0 and the next one up is called 1, and the energy between them corresponds to a microwave frequency of around 5 GHz in a typical design and about 6 GHz on Willow, the range of a Wi-Fi radio. A microwave pulse at that frequency can lift the circuit from 0 to 1 or bring it back. The circuit has further levels above 1, and they stay unused. A practical guide to these devices describes why: the step from 1 to 2 is designed to be smaller than the step from 0 to 1, typically by 200 to 300 MHz, so a pulse tuned to the first step does not drive the second.
The uneven spacing matters. A weight on an ideal spring has evenly spaced levels, and so does an ordinary electrical resonator, a circuit that oscillates at one natural frequency. A pulse that lifts either of them one step would lift it the next step too, so it cannot be confined to two levels. The name transmon comes from a 2007 paper describing a design that made the circuit insensitive to stray electric charge, which had disturbed earlier versions. The price was that the levels became a little more evenly spaced. Both IBM and Google build their processors from transmons.
Many ways to make two levels
Any physical system with two levels that can be controlled and told apart can serve as a qubit. The main approaches differ in what those levels are, and the table lists five that appear in later chapters.
| Kind of qubit | What 0 and 1 are | Controlled with | Examples in this guide |
|---|---|---|---|
| Superconducting circuit (transmon) | the two lowest energy levels of the circuit | microwave pulses | Google Willow, IBM Heron |
| Trapped ion | two levels of an ion's outermost electron, split by the nucleus's magnetism | microwaves or lasers | ytterbium-171 (12.6 GHz apart); barium-137 in Quantinuum Helios |
| Neutral atom | two such levels of an uncharged atom held in a laser beam | lasers | rubidium-87 arrays |
| Photon | one photon in one of two waveguides | optical components on a chip | PsiQuantum's "dual-rail" qubits |
| Electron spin | an electron's spin pointing with or against a magnetic field | microwaves and voltages | silicon quantum dots |
The approaches differ in more than their parts list. Every ytterbium-171 ion is identical to every other, so ion and atom qubits start out alike and differ only through their surroundings. Transmons are manufactured, and no two come out exactly the same, so each one's frequency and pulses must be measured and tuned, a process called calibration that Chapter 18 describes. Photons need no refrigerator to hold their state but are hard to make interact. Electron spins in silicon borrow the methods of the chip industry, but they sit in material whose stray nuclei disturb them. Chapter 19 sets out what limits each approach.
Older superconducting designs used other pairs of states. The flux qubit stores 0 and 1 as electric currents circulating in opposite directions around a small loop interrupted by three or four junctions. It was described in 1999 and is still studied, but the superconducting processors in the error-correction experiments of Part V are built from transmons, whose 0 and 1 are energy levels, not currents.
Reading gives one bit
Reading a qubit, which physicists call measurement, always produces one of two answers, 0 or 1. A transmon is read by sending a weak microwave tone past a small resonator coupled to it. The resonator's response shifts slightly depending on whether the qubit is in 0 or 1, and Chapter 18 follows that faint signal to the decision between 0 and 1. A trapped ion is read by shining a laser that makes it glow in one of its two states and stay dark in the other. Either way, the output is a single classical bit.
Reading takes time, and the time is part of the cost. The operations that change a qubit's state without reading it are called gates (Chapter 4). On Willow a single-qubit gate takes 25 nanoseconds and a two-qubit gate 42. The readout tone lasts between about 250 and 480 nanoseconds, so a reading is the slowest routine operation on the chip. Small laboratory devices have been read in 100 nanoseconds with errors of about 1 in 400, but reading all the qubits of a large chip at once, as error correction requires, is harder than reading one well.
The reading also changes the qubit. Whatever the qubit held before, afterward it is ideally in the level that was read, and a second reading straight after the first gives the same answer. Readings also err: Google's specification sheet for its Willow error-correction chip gives an average measurement error of 0.77 %. Quantinuum builds quantum computers from trapped ions. In a 2025 paper, its staff report that the company's Helios machine prepares a qubit in a known state and then measures it with a combined error of about 1 in 2,000.
Odds, estimated by repetition
A qubit can be prepared so that a reading gives 0 seventy times in a hundred and 1 thirty times. One reading reveals nothing about those odds: it is a single 0 or 1. The odds show up only when the same preparation is repeated and read many times, and each repetition is called a shot. Every probability a quantum computer reports is an estimate from shots, and its precision is paid for in shots.
Prepare a qubit with odds of 70 % for 0, and read it 1,000 times. The expected count of zeros is 700. The spread of such counts follows the rule for repeated coin tosses: the square root of 1,000 × 0.7 × 0.3, or about 14.5. About 95 % of runs of 1,000 shots fall within about two spreads of 700, between about 672 and 728 zeros, an estimate of 70 % give or take about 3 percentage points. The spread shrinks only with the square root of the shots: four times as many shots halve it, and a spread of a tenth of a percentage point needs about 210,000 shots.
The odds describe how the qubit was prepared, and the same odds can come from preparations that are physically different. Here a qubit stops resembling a biased coin. After one more operation, two qubits prepared with the same 70/30 odds can give quite different results, and the difference lies in something a single reading never shows. Chapter 3 introduces it.
A qubit read as 0 was not secretly 0 before the reading, waiting to be discovered, in the way a coin under a hand is already heads or tails. Experiments of the kind described in Chapter 3 rule out the simplest such picture. The odds are a property of the preparation, and only repeated preparations reveal them.
The cost already visible
Two parts of the price this guide adds up appear in this chapter. The first is shots: an answer read from one run is one sample, and an answer known to a given precision needs many runs. The second is error: on full processors in 2026, two-qubit gates and readouts still fail between about 1 time in 2,000 and 1 time in 100, depending on the machine and the operation. Chapter 12 shows where those errors come from, and Chapter 13 how they compound over a long computation.
How many shots an answer needs depends on the question. An algorithm whose answer can be checked needs only the few runs its method uses, and a pair of factors is such an answer, because the factors either multiply to the target or do not. In a design for Shor's algorithm posted as a preprint in 2025, Craig Gidney of Google Quantum AI combines about nine runs per factorization in the classical post-processing. An algorithm that estimates an average, such as the energy of a molecule, needs enough shots to bring the spread below the precision wanted. Chapter 10 shows how that requirement can dominate the cost.
A count of qubits says little by itself. Ask for the error of each kind of operation: preparation and readout, single-qubit gates and two-qubit gates, with how long each takes and how long the qubits hold their state. Ask whether figures are medians, means or best cases, and how widely they vary across the chip. Ask whether each ± value describes that spread or the uncertainty of a measurement, and how many shots stand behind each figure.
- A qubit is any physical system with two levels that can be controlled and told apart; IBM's and Google's are transmons, whose 0 and 1 are the two lowest energy levels of a superconducting circuit.
- A transmon's uneven level spacing lets a pulse at around 5 GHz drive the step from 0 to 1 without touching the levels above.
- Reading a qubit gives one bit, leaves the qubit in the state read, and itself errs: Helios's preparation and reading together err about 1 time in 2,000, and Willow's measurements about 1 time in 130.
- Odds are estimated only from many shots, and their precision improves with the square root of the number of shots.
Let's Talk