Beating a supercomputer, and the reply.
+ The questionWhen a quantum computer is said to have beaten a supercomputer, what was the contest, and did the result hold?
A sample nobody can check
In September 2019 a paper by Google's quantum team appeared briefly on a NASA website and was taken down, and on 20 September the Financial Times reported its claim. Nature published the paper on 23 October. It described Sycamore, a processor with 53 working qubits, running random circuits of 20 cycles. In this kind of experiment, a cycle is one layer of single-qubit gates and one layer of two-qubit gates across the chip. Sycamore collected a million output strings in about 200 seconds. The authors estimated that the largest supercomputer would need about 10,000 years to produce the same samples. They called the result quantum supremacy, meaning that a quantum computer had done a task beyond the reach of any classical computer in a reasonable time. The field now mostly says quantum advantage.
The task, called random circuit sampling, was chosen because it is hard to imitate, not because anyone needs its output. A random sequence of gates spreads the register over all its strings with a pattern of odds no simple rule describes, and the machine is asked to produce strings with those odds. Whether the machine did so cannot be checked directly for 53 qubits.
The authors estimated the quality of their samples with a statistic called cross-entropy benchmarking, which scores the strings the machine produced against the odds that a simulation of the ideal circuit predicts. They computed it exactly on smaller and simplified versions of the circuits and extrapolated to the full one. They found a fidelity of about 0.2 %, which means that about one sample in 500 carried the intended pattern and the rest were noise.
The reply, and the replies to the reply
IBM's researchers answered days before the paper appeared. In a preprint and a blog post of 21 and 22 October 2019, they estimated that Summit could do the job in about two and a half days, and more exactly than the chip. Their method used Summit's disks to hold the full register, as Chapter 5 described. They never ran that computation.
Others did run classical methods. In 2022 a team at the Chinese Academy of Sciences produced a million samples of higher fidelity than Sycamore's in about 15 hours on 512 graphics processors. In 2024 a team including researchers from the University of Science and Technology of China produced three million samples in 86.4 seconds on 1,432 graphics processors. Sycamore had taken 600 seconds for that many samples, but the classical run used about three times as much energy as the chip. In a later analysis, Google's own researchers put the 2019 experiment at about 6 seconds on the Frontier supercomputer.
Ten thousand years is about 3.2 × 10¹¹ seconds, so the 2019 claim was a ratio of about 1.6 billion over Sycamore's 200 seconds. IBM's estimate of two and a half days is about 216,000 seconds, which cut the ratio to about 1,080. The 2024 GPU run took 86.4 seconds against Sycamore's 600 for three million samples, which turned the ratio below one: the classical machine was about seven times faster. Each figure was correct for the classical method it assumed. The ratio measured the methods known at the time, not the problem.
Later sampling experiments used larger circuits to stay ahead of the classical methods. In a 2024 Nature paper, Google's team used 67 qubits and 32 cycles and estimated about 10,000 years on Frontier using its memory alone, or about 12 years if its disks could be used as well, an assumption the team did not test. In December 2024 Google announced a run on 103 of Willow's qubits that it said would take Frontier 10²⁵ years. That estimate assumed unlimited fast disk storage, and it appeared in a company announcement and specification sheet rather than in a peer-reviewed paper. In March 2025, researchers at the University of Science and Technology of China published results from their Zuchongzhi 3.0 processor, which sampled 83-qubit circuits, and estimated about 5.9 billion years on Frontier. As far as the sources for this guide show, no practical classical reproduction of these larger runs had appeared by October 2026. None of them can be checked directly either.
Answers that can be checked, at a price
The claims since 2025 have moved toward outputs that can be checked in some way. In March 2025, a team from JPMorganChase, Quantinuum, US national laboratories and universities reported its results in Nature. The team used a 56-qubit trapped-ion machine, reached over the internet, to produce 71,313 bits of certified randomness: random numbers whose randomness is proved by checking samples against a classical computation. The proof holds under stated assumptions about what an adversary can compute. The check took a sustained 1.1 exaflops, or 1.1 × 10¹⁸ arithmetic operations per second, across four US supercomputers, Frontier and Summit among them, so the output was verifiable, but at the cost of some of the largest classical machines.
In October 2025 Google reported Quantum Echoes, a measurement of how a disturbance spreads through a quantum system and partly refocuses, made on 65 of Willow's qubits. Its output is a set of average values rather than random strings. Another quantum computer or a physical experiment could in principle reproduce those values, and that is the sense in which Google called the result verifiable. Google estimated about 3.2 years on Frontier for each data point against 2.1 hours on the chip, a ratio of about 13,000.
A 2026 study found that one leading class of tensor-network methods could not simulate Quantum Echoes, but several of the study's authors work at Google. Tensor-network methods are classical methods that store a quantum state as a network of many small, linked arrays of numbers. As of October 2026, an independent classical reproduction had not appeared.
Sampling of a different kind was tried with light. In December 2020 the University of Science and Technology of China reported Jiuzhang, an optical machine that sent squeezed light through a network of 100 paths and counted the photons at its outputs. The task is called boson sampling, because photons belong to the family of particles called bosons. Squeezed light is light prepared so that its quantum noise is lower in one property and higher in another. Jiuzhang's authors estimated that the Sunway TaihuLight supercomputer would need about 2.5 billion years for the samples the machine produced in 200 seconds. With modest computing resources, a 2024 classical algorithm that exploits the loss of photons in such machines outperformed the experiments on the benchmarks used as their evidence.
The 2026 round
On 30 July 2026, IBM announced quantum advantage through three preprints written with partners. IBM wrote the first with the University of Chicago. It described a circuit on 70 encoded qubits that ran inside an error-detecting code, 97 physical qubits in all. An error-detecting code spreads the information of the encoded qubits over a larger number of physical qubits, so that errors can be noticed, though not corrected. Shots that showed a detected error were discarded. The run took about 15 minutes, and a statistical bound certified the fidelity of its result at 0.284 or better.
In the other two preprints, the case rested on different classical methods disagreeing with each other about the answer, not on any one of them being shown wrong. In its own announcement, IBM added that announcing advantage "does not close the case—it opens the results to a new level of scrutiny." The scrutiny came quickly. In mid-August 2026, about two weeks after IBM's announcement, researchers at the Singapore University of Technology and Design and the chipmaker NVIDIA reported a classical simulation of the first circuit in a preprint. Their simulation took 37.3 minutes on 256 graphics processors, at a fidelity consistent with IBM's bound. The chip had been faster, but a claim of advantage asserts that the task is beyond the reach of classical computers, and a task that 256 graphics processors finish in under an hour is not.
The pattern had appeared before: IBM's 2023 "utility" experiment drew a classical reproduction within 12 days. In a March 2025 Science paper on the dynamics of magnetic models, D-Wave claimed a classical cost of millions of years on Frontier. D-Wave builds quantum annealers, special-purpose machines described in Chapter 19. Five days before D-Wave's paper appeared, the Flatiron Institute had posted a classical preprint that matched or beat D-Wave's accuracy on most of the lattices tested, and that preprint was later published in Science as well.
| Claim | Year | Quantum time | Classical estimate when claimed | What followed |
|---|---|---|---|---|
| Sycamore, random sampling | 2019 | 200 s | 10,000 years | 86.4 s on 1,432 GPUs by 2024, against 600 s on the chip for 3 million samples |
| Jiuzhang, photon sampling | 2020 | 200 s | 2.5 billion years | 2024 classical method beat its benchmarks |
| IBM Eagle, magnetic dynamics | 2023 | (not compared) | beyond brute force | reproduced classically within 12 days |
| D-Wave, annealing dynamics | 2025 | minutes | millions of years | tensor networks matched most lattices |
| Google Quantum Echoes | 2025 | 2.1 h per point | 3.2 years per point | no independent reproduction yet |
| IBM and Chicago, encoded sampling | 2026 | about 15 min | far longer, by IBM's estimate | 37.3 min on 256 GPUs, in a preprint |
A ratio of times compares a quantum machine with one classical method on one classical machine, as estimated at one moment. The estimate can fall by orders of magnitude when someone improves the method, and it often does within months. Read the ratio as a statement about the state of classical algorithms as well as about the quantum computer.
The one check that settles a claim
Factoring sits at the far end of the scale of checkability: a claimed pair of factors is verified by one multiplication. That makes factoring the cleanest possible demonstration, and Chapter 8 showed why none has yet been made beyond 15. In a 2026 review, Dominik Hangleiter summarized the state of the field: quantum computers can now perform tasks that no classical computer can, but those tasks are close to useless, and the next milestone is a quantum advantage that ordinary computers can verify.
What was the task, and is its output useful to anyone? Which classical method and machine served as the baseline, and was the classical estimate run or extrapolated? Can the output be checked, and by whom: nobody, another quantum computer, or an ordinary computer? Has anyone outside the claiming team tried to reproduce it classically? And what happened in the months after the announcement?
- Random circuit sampling, used for the 2019 Sycamore claim and its successors, produces output that nobody can check directly and that has no use of its own.
- Sycamore's 10,000-year estimate fell to an estimated 2.5 days before the paper even appeared, and by 2024 a classical run was about seven times faster than the chip, because each ratio measured the classical methods known at the time.
- Claims since 2025 have moved toward checkable outputs, such as certified randomness, verified at the cost of four supercomputers, and Quantum Echoes, which another quantum machine could reproduce.
- The first of IBM's three July 2026 claims was answered by a 37-minute GPU simulation about two weeks later, and as of October 2026 no advantage has been shown that is both useful and classically verifiable.
Let's Talk