From physical to logical.
+ The questionHow many physical qubits make one logical qubit good enough for a billion operations?
What one logical qubit costs
A logical qubit is a qubit made of many physical ones by an error-correcting code, so that its error rate is set by the code and the quality of its parts rather than by any single part. It is the protected qubit of the earlier chapters. The surface code of Chapter 15 makes the cost of one easy to estimate, because only two numbers matter: the error rate the computation needs and the slope Λ the hardware achieves. The solved example works the arithmetic for four slopes, from about Willow's to the slope that physical errors at a tenth of the threshold would give.
The rule of Chapter 15 gives an error per cycle of 0.03 divided by Λ raised to a power equal to half of one more than d, and a patch size of 2d² − 1. For each target, the calculation finds the smallest distance that reaches it. For 1 error in 10⁹ per cycle, Λ = 2 needs distance 49 and 4,801 qubits, and Willow's 2.14 needs distance 45 and 4,049. Λ = 4 needs distance 25 and 1,249 qubits, and Λ = 10 needs distance 15 and 449. For 1 in 10¹², the same four slopes need 9,521, 7,937, 2,449 and 881 qubits. Doubling Λ from 2 to 4 cuts the cost of each logical qubit by about a factor of four. The calculation holds the 0.03 fixed and assumes no floor, so it is a guide to scale, not a design.
Published designs sit across that range. In 2012 Fowler and colleagues estimated about 14,500 physical qubits per logical qubit for their factoring machine. In a 2025 preprint, Craig Gidney of Google Quantum AI set out a design for RSA-2048. It uses 1,352 physical qubits per logical qubit for the qubits being worked on, at distance 25, a count that includes room for routing between patches and so exceeds the 1,249 that the rule of Chapter 15 gives. Qubits waiting in storage need only about 430 each, because the design adds a second layer of checks across groups of stored patches, a scheme called yoked surface codes. Averaged over the whole machine, including the factories described next, the design spends about 640 physical qubits per logical qubit.
The layout of Gidney's machine shows where the qubits go. About 1,280 logical qubits wait in yoked storage at about 430 physical qubits each, some 550,000 in all. About 131 are being worked on at any moment, at 1,352 each, some 177,000. The remaining 170,000 or so make up the working area where arithmetic happens and six factories prepare the ingredients for Toffoli gates. The total is 897,864 physical qubits, the figure behind the headline of fewer than a million.
The gate the code does not make easy
A surface code makes some operations cheap. Two patches can be merged and split again to perform a CNOT between their logical qubits, a technique called lattice surgery. A 2012 paper described such a CNOT between two distance-3 patches that uses 53 physical qubits. The Hadamard and S gates are similarly manageable. The T gate is not, as Chapter 4 warned. Neither are the Toffoli gates of Shor's arithmetic, which are built from T gates or performed directly with prepared ingredients.
In 2005 Sergey Bravyi and Alexei Kitaev found a way to perform such gates anyway. Their method prepares the special magic states of Chapter 4 separately, accepts that they come out noisy, and refines them. The refining is called distillation, and it consumes many noisy copies to produce fewer, better ones. A protected T gate then consumes one good magic state. The refining happens in magic state factories, regions of the chip that do nothing else, and in older designs the factories took up most of the machine.
In 2024 Gidney, Noah Shutty and Cody Jones of Google proposed cultivation, which grows a single magic state gradually inside one patch. In their simulations, cultivation reached errors of about 2 in 10⁹ at a physical noise of 1 in 1,000, with about a tenth of the space and time of earlier methods. In a December 2025 preprint, Google's team reported growing such states on a superconducting chip, keeping 8 % of the attempts, in the experiment described in Chapter 4.
The factories also set the pace of a computation. In Gidney's design, six of them feed the arithmetic. Over a whole factorization, the machine completes one Toffoli gate about every 66 microseconds on average. Fewer factories would mean fewer qubits and a longer run, which is the trade Chapter 22 follows through the estimates.
Codes with less overhead
The surface code's cost comes from its simplicity: each check involves four neighbors, and the code protects one logical qubit per patch. Codes whose checks reach further can pack many logical qubits into one block. In a 2024 Nature paper, a team at IBM described a code of this family, a quantum low-density parity-check code. The name says that each check involves only a few qubits and each qubit takes part in only a few checks. IBM's code would store 12 logical qubits in 288 physical qubits, 24 per logical qubit, with a threshold of 0.8 %, where a surface code with the same protection would need nearly 3,000. The cost is in the wiring: each qubit must be coupled to six others, some of them far away, which needs two layers of connections on the chip.
IBM's result was a simulation, and hardware able to run such codes lags behind it. A team at Zhejiang University published the first superconducting demonstration of such codes in 2026. Its codes erred about 8 to 9 % per logical qubit per cycle, far above Willow's surface code. IBM's own roadmap is a company plan. It lists Kookaburra, a first chip storing information in such a code, for 2026, and Starling, a fault-tolerant machine with 200 logical qubits running 100 million gates, for 2029. IBM had not announced Kookaburra as delivered by early October 2026 (Chapter 20). In a February 2026 preprint, the start-up Iceberg Quantum proposed a design that uses such codes with the same error assumptions as Gidney's. By its estimate, fewer than 100,000 physical qubits could factor RSA-2048 in about a month, or about 381,000 in a single day, provided the hardware offers the longer-range links the codes need.
Other teams reduce overhead through the qubits themselves. Amazon's Ocelot chip of 2025 used cat qubits, oscillators whose bit flips are suppressed by design, which leaves mainly phase errors for a simple code to catch. The French company Alice & Bob, which builds the same kind of qubit, reported bit-flip times above ten seconds in 2024.
What "logical qubit" means in announcements
Counts of logical qubits have appeared in many announcements since 2023, and they are not counted the same way. In a careful 2025 review, John Preskill, who is not a vendor, distinguished error detection from error correction. He stressed that discarding runs with detected errors, called post-selection, does not scale to long computations, because the share of runs kept shrinks with their length. He noted that on atomic platforms "it has not been possible to perform more than a few rounds of error syndrome measurement," and that results there relied on detection and post-selection. That was the case when he wrote, and several 2025 results went further. The claims fall on three rungs. Atom Computing, named in the table, builds machines from neutral atoms, as QuEra does.
| Rung | What the code does | Examples |
|---|---|---|
| Detected, with post-selection | finds errors and discards the run; often distance 2 | 48 logical qubits on an array of up to 280 atoms (Harvard and QuEra, 2023); up to 96 distance-4 logical qubits with errors detected (Harvard and QuEra, 2025); 24 on 48 atoms (Microsoft and Atom Computing, 2024); 94 on Quantinuum's Helios (2025, company figure); 70 encoded qubits on 97 (IBM and the University of Chicago, 2026, preprint) |
| Corrected for a few rounds | corrects errors, often with some runs discarded | 8 logical qubits through five rounds of correction, with half the runs discarded (Microsoft and Quantinuum, 2024); a distance-5 surface code corrected over four rounds on an array of up to 448 atoms (Harvard and QuEra, 2025); 48 error-corrected on Helios (2025, company figure) |
| Repeated memory, Λ above 1 | corrects every cycle, errors fall as the code grows | one logical qubit at distance 7 on Willow, decoded after the run, and one at distance 5 decoded in real time on a second Willow processor (2024; improved in 2026) |
Every rung is real progress, and the lower rungs often run more logical qubits at once than the top one. None of them yet provides logical qubits at the 1 in 10¹⁵ that RSA-2048 needs. None yet reaches the 1 in a million per operation that Preskill takes as the mark of a first useful error-corrected machine. He calls it a megaquop machine, because it would run a million operations. In June 2026 Alice & Bob published five criteria for logical-qubit claims. The criteria are a vendor's framework, and among other things they ask whether performance holds across all runs rather than after heavy post-selection.
A headline count of logical qubits needs three qualifiers before it means anything: the code distance, whether errors were corrected or only detected, and what share of runs was kept. A distance-2 code with post-selection and a distance-7 memory checked in every cycle are both called logical qubits, and they are separated by orders of magnitude in what they can sustain.
For a claim of logical qubits, ask for the logical error per operation or per cycle, the number of cycles or operations sustained, the share of runs kept if any were discarded, and the physical qubits used per logical qubit. Then compare those figures with the budget of Chapter 13 for the computation in view. The ratio of physical to logical qubits matters less than whether the logical error rate falls as the code grows.
- A logical qubit's cost follows from the error rate needed and the slope Λ: for 1 error in 10⁹ per cycle, about 4,800 physical qubits at Λ = 2 and about 450 at Λ = 10.
- Cheap operations on surface codes include CNOTs by lattice surgery, while T and Toffoli gates need magic states, refined in factories or grown by cultivation.
- Codes with longer-range checks promise far less overhead, such as 12 logical qubits in 288 physical qubits on paper, but their first hardware runs erred 8 to 9 % per cycle.
- Logical-qubit counts in announcements span detected and post-selected codes, codes corrected for a few rounds, and memories corrected every cycle, and only the last has sustained correction cycle after cycle with errors falling as the code grows.
Let's Talk