§ Glossary
Glossary.
Terms are defined as they are used in this guide.
- Amplitude
- The arrow of this guide: a length and a direction attached to each possible outcome of a measurement, whose squared length gives that outcome's probability.
- Ancilla
- An extra qubit used to check other qubits, for example by collecting their parity, and then measured without measuring them.
- Attenuator
- A component that absorbs most of a signal and turns it into heat at its own temperature stage, removing the thermal noise that came down with it.
- Bell pair
- Two entangled qubits whose readings always agree, or always disagree, although each reading alone is random.
- Break-even
- The point at which a protected qubit holds its information longer, or errs less, than the best of the physical qubits it is made from.
- Cat qubit
- A qubit stored in an oscillator whose bit flips are suppressed by design, so that a simple code need correct mainly phase errors.
- Certified randomness
- Random bits produced by a quantum computer together with a classical test showing, under stated assumptions, that they could not have been generated in advance.
- Code distance
- The smallest number of physical errors that can change a protected qubit without being detected; written d.
- Coherence time
- How long a qubit keeps its state: T1 for loss of energy, T2 for loss of phase.
- Color code
- An error-correcting code related to the surface code in which more gates can be applied directly to the protected qubits.
- Controlled-NOT (CNOT)
- A two-qubit gate that flips the target qubit when the control qubit is 1, and entangles them when the control is in a superposition.
- Controlled-Z (CZ)
- A two-qubit gate that reverses the phase of the arrow for the outcome in which both qubits are 1; the native two-qubit gate of Willow.
- Coupler
- A circuit element that joins two qubits so that a two-qubit gate can act on them, often tunable so the interaction can be switched off.
- Cross-entropy benchmarking (XEB)
- A score that checks whether a machine's samples favor the outcomes a simulation says should be likely; used to estimate fidelity in random circuit sampling.
- Cultivation
- A method of growing a magic state gradually inside one code patch, checking it as it grows, instead of distilling many noisy copies.
- Cycle
- One round of an error-correcting code in which every check is measured once; about 1.1 microseconds on Willow.
- Decoder
- The classical computer and algorithm that turn a stream of check results into a judgment of which errors most likely occurred.
- Decoherence
- The loss of a qubit's state to its surroundings, through energy relaxation and dephasing.
- Dephasing
- Loss of the relative direction of a qubit's arrows, scrambling the phase without changing the odds of 0 and 1.
- Depth
- The number of time steps a circuit takes when gates on separate qubits run at the same time.
- Dequantization
- A classical algorithm that matches a claimed quantum speedup by using the same access to data the quantum algorithm assumed.
- Dilution refrigerator
- A refrigerator that cools to a few thousandths of a degree above absolute zero by letting helium-3 cross into a dilute mixture with helium-4.
- Discrete logarithm
- The power to which a number must be raised, in modular arithmetic, to give another; Shor's algorithm finds it as efficiently as it factors.
- Dispersive readout
- Reading a qubit through the small frequency shift it causes in a coupled resonator, without the qubit absorbing the probe.
- Distillation
- Producing a few high-quality magic states by consuming many noisy ones.
- DRAG pulse
- A shaped control pulse with an added component that keeps a transmon from leaking into its third level.
- Energy relaxation
- A qubit in 1 decaying to 0 by giving its energy to the surroundings; its time constant is T1.
- Entanglement
- A shared state of two or more qubits that cannot be described qubit by qubit, so their readings are correlated beyond anything separate objects allow.
- Error detection
- A code that flags errors without being able to correct them; runs with flagged errors are discarded.
- Fault tolerance
- Computing with protected qubits in such a way that errors during the checking itself do not spread uncontrollably.
- FeMoco
- The iron-molybdenum cofactor of the nitrogenase enzyme, a metal cluster whose electrons are a standard test case for quantum chemistry.
- Fidelity
- How close an operation or state comes to the ideal one; a two-qubit gate fidelity of 99.9 % means an error of about 1 in 1,000.
- Fusion
- A measurement on two photons that entangles the clusters they belong to; the basic operation of PsiQuantum's photonic design.
- Gate
- An operation that turns a qubit's arrows, or the arrows of two or three qubits together, by a set amount.
- General number field sieve
- The fastest known ordinary algorithm for factoring large numbers such as RSA keys; its cost grows faster than any polynomial and slower than any exponential.
- Grover's algorithm
- A quantum search that finds a marked item among N in about the square root of N steps, by repeated reflections that amplify the marked item's arrow.
- Hadamard gate
- A single-qubit gate that turns 0 into an equal superposition of 0 and 1, and back again when applied twice.
- Interference
- The adding of arrows for the different ways an outcome can happen, so that some outcomes reinforce and others cancel.
- Josephson junction
- A thin insulating barrier between two superconductors that gives a superconducting circuit unequally spaced energy levels.
- Lambda (Λ)
- The factor by which a code's logical error falls for each increase of two in code distance; above 1 means the code is below threshold.
- Lattice surgery
- Merging and splitting code patches to perform gates such as CNOT between the logical qubits they hold.
- Leakage
- A qubit escaping its two working levels into a higher one, an error that ordinary codes do not catch.
- Logical qubit
- A protected qubit made from many physical qubits by an error-correcting code.
- Magic state
- A specially prepared state consumed to perform a T gate or Toffoli gate on protected qubits.
- Magic state factory
- A region of a fault-tolerant machine that does nothing but prepare magic states.
- Mixing chamber
- The coldest plate of a dilution refrigerator, on which the quantum chip sits.
- Modular arithmetic
- Arithmetic on a clock: numbers wrap around after a fixed modulus, so 7 × 13 mod 15 is 1.
- Neutral atom
- An uncharged atom held in a laser trap and used as a qubit; atoms interact when excited to a Rydberg state.
- No-cloning theorem
- The result that an unknown quantum state cannot be copied, which rules out protecting qubits by keeping backup copies.
- Optical tweezers
- Tightly focused laser beams that hold single atoms and can move them.
- Oracle
- The part of a search circuit that marks the item sought; it must be built as a circuit, and its cost counts.
- Parametric amplifier
- A superconducting amplifier, pumped by a microwave tone, that adds close to the least noise quantum physics allows.
- Parity check
- A check that reports whether a group of qubits holds an even or odd number of 1s, without revealing the individual values.
- Pauli error
- An error measure for gates that counts bit flips, phase flips and both; for a two-qubit gate it is five fourths of the average error.
- Period finding
- Finding how often a sequence repeats; the step of Shor's algorithm that a quantum computer performs.
- Phase
- The direction of a qubit's arrow; it cannot be read directly but decides how arrows interfere.
- Physical qubit
- A qubit as built, a circuit, ion, atom, photon or spin, with its own error rate.
- Polynomial and exponential
- Two ways a cost can grow with the size of a problem: as a fixed power of the size, or by a fixed factor for each step up in size.
- Post-selection
- Discarding the runs in which an error was detected and keeping the rest; the share kept shrinks as computations grow longer.
- Quantum advantage
- A task performed by a quantum computer faster, or at all, beyond what the best ordinary computers can do; the claim depends on the classical method compared.
- Quantum annealer
- A machine that lets a network of qubits settle toward a low-energy state rather than running sequences of gates.
- Quantum dot
- A region of a semiconductor, defined by electrodes, that holds single electrons whose spins serve as qubits.
- Quantum Fourier transform
- The step of Shor's algorithm that turns a periodic pattern of arrows into peaks at multiples of the inverse period.
- Quantum LDPC code
- An error-correcting code whose checks reach beyond nearest neighbors, storing many logical qubits in one block with fewer physical qubits each.
- Qubit
- A physical system with two levels, 0 and 1, that can be prepared, turned, entangled and read.
- Qubit-hours
- The number of qubits kept protected multiplied by the hours they must be kept, a measure of the work in a computation.
- Random circuit sampling
- Running random sequences of gates and collecting samples, a task designed to be hard for ordinary computers to imitate.
- Reaction time
- The time from reading the checks of a code to applying a gate that depends on the decoded result.
- Resonator
- A circuit that rings at one frequency; coupled to a qubit, it is used to read the qubit's state.
- RSA-2048
- A 617-digit challenge number whose size matches the 2,048-bit keys of RSA encryption; one of the two cases this guide follows.
- Rydberg state
- A highly excited state of an atom in which the outer electron orbits far from the nucleus, letting nearby atoms interact.
- Shor's algorithm
- Peter Shor's 1994 method for factoring numbers and finding discrete logarithms on a quantum computer by period finding.
- Shot
- One run of a quantum program ending in one reading of each qubit.
- Spin qubit
- A qubit stored in the spin of a single electron, usually in a quantum dot in silicon.
- Surface code
- The error-correcting code on a square grid whose checks involve only neighboring qubits; the code most designs for superconducting quantum computers use.
- Syndrome
- The pattern of check results that points to which error occurred.
- T gate
- A single-qubit gate that turns the arrow by an eighth of a turn; needed for universal computation and the costliest gate to protect.
- Thermal photon
- A unit of energy that warm surroundings supply at a qubit's frequency; one absorbed by a qubit in 0 flips it to 1.
- Threshold
- The physical error rate below which making a code larger lowers the logical error instead of raising it.
- Toffoli gate
- A three-qubit gate that flips the target only when both controls are 1; the basic step of the arithmetic in Shor's algorithm.
- Topological qubit
- A proposed qubit that would store information in collective states of special superconducting wires, protected from local errors by their nature.
- Transmon
- The most common superconducting qubit, a small circuit with a Josephson junction whose two lowest energy levels serve as 0 and 1.
- Trapped ion
- A charged atom held by electric fields in a vacuum and used as a qubit, driven by lasers or microwaves.
- Variational quantum eigensolver
- A method that runs short quantum circuits whose settings an ordinary computer adjusts to lower an estimated energy.
- Yoked surface code
- Surface-code patches in storage joined by an extra layer of checks across groups of patches, so each needs fewer physical qubits.
Let's Talk