+ Part III · Which problems

Where the advantage is real, and how claims have fared.

In October 2019, Google's team published a paper reporting that its processor had finished in 200 seconds a task that, by the authors' estimate, would take the largest supercomputer 10,000 years. Days before their paper appeared, IBM's researchers put the classical figure at two and a half days. Part III answers the second half of the central question: for which problems is a reliable answer worth its price? Chapter 9 sets out what structure a problem needs. Chapter 10 follows the problem quantum computers were first proposed for, the simulation of molecules and materials. Chapter 11 weighs the claims of advantage made since 2019 against the classical replies they drew.

09 — Structure

What a speedup needs.

+ The questionWhy do period finding and simulation speed up while sorting and spreadsheets do not?

A speedup that disappeared

In 2018 a quantum algorithm lost its advantage to an ordinary one. The quantum algorithm recommended products to customers from a table of their past choices, and it had been presented as exponentially faster than any ordinary method. Iordanis Kerenidis and Anupam Prakash had published it in 2016. Ewin Tang found the ordinary algorithm. Tang was 18, had just graduated from the University of Texas at Austin, and had begun the work as an undergraduate thesis supervised by Scott Aaronson, as Quanta Magazine reported. Given the same kind of access to the data as the quantum method, Tang's method was only polynomially slower, so the exponential gap was gone.

Finding such an ordinary algorithm is now called dequantization, and it has been done for several other proposed quantum speedups in data analysis. The lesson of dequantization is that every claim of quantum advantage is a claim about the best known ordinary method, and that the best known ordinary method can improve. A speedup over a classical algorithm nobody has worked hard on is weak evidence. Factoring has resisted classical attack for decades, with no polynomial method found, and a speedup on a problem like that is far stronger evidence.

A speedup is only as strong as its classical baseline

Claims often compare a quantum method with a generic classical solver, an old algorithm or one processor core. The baseline that matters is the best classical method for that problem, on the best hardware, given the same access to the data. Several reported speedups have disappeared when that baseline was found, and Chapter 11 shows the pattern repeating in public.

Three conditions

A problem repays a quantum computer only when three conditions hold together. The first is a large gap in growth rate between the best quantum method and the best ordinary one, large enough to survive the slowness of error-corrected operations that Chapter 6 measured. In practice that means an exponential gap or a high-power one, and such gaps have come only from structure: a hidden period or symmetry, as in Shor's algorithm, or the quantum physics of the problem itself, as in the simulation of molecules. In the 2021 analysis of Chapter 6, a square-root gain took from hours to hundreds of thousands of years to break even, while a fourth-power gain broke even within minutes to hours.

The second condition is that the input be small. A quantum computer must have its input built into its circuit or loaded gate by gate, and its input and output channels are slow. In a 2023 analysis, Torsten Hoefler, Thomas Häner and Matthias Troyer estimated that a future machine with 10,000 protected qubits would move data at about 1 gigabit per second, against about 10,000 gigabits per second for a modern graphics processor. The authors included Microsoft staff, and they summarized the consequence as big compute on small data.

Solved example: loading a terabyte

A terabyte is 8 × 10¹² bits. At 1 gigabit per second, loading it into the quantum machine takes 8 × 10¹² ÷ 10⁹ = 8,000 seconds, about 2.2 hours, before any computation starts. A graphics processor at 10,000 gigabits per second reads the same terabyte in 0.8 seconds. A quantum algorithm that touches every entry of a large dataset has lost its advantage before it begins, whatever its growth rate on paper.

23 — Loading a terabyte
0.1 s 1 s 1 min 1 h 1 day TIME TO LOAD, LOG SCALE graphics processor, 10,000 Gbit/s: 0.8 s future quantum machine, 1 Gbit/s: 8,000 s ≈ 2.2 h 2.2 hours before any computation starts 1 terabyte = 8 × 10¹² bits; I/O rates from Hoefler, Häner and Troyer 2023
AmplitudeReadoutFocal detail
Plate 23 — At about 1 gigabit per second, a terabyte takes 2.2 hours to load into a quantum machine, against 0.8 seconds for a graphics processor. Problems with large inputs lose any quantum advantage before it starts.

The third condition is that the answer can be read out in a few samples. A reading returns one string, so an algorithm whose result is a long list of numbers must be run at least once for every number wanted. A short, checkable answer fits the machine: a yes or no, a pair of factors, or an energy to a stated precision. An answer that is a large table does not.

The fine print of linear algebra

A celebrated 2009 algorithm by Aram Harrow, Avinatan Hassidim and Seth Lloyd solves large systems of linear equations in a time that grows only with the logarithm of their size, roughly the number of digits in that size. On paper that is an exponential gain. In a 2015 commentary titled "Read the fine print," Aaronson listed what the gain assumes. The right-hand side of the equations must be loaded quickly. The matrix, the table of numbers that multiply the unknowns in the equations, must be sparse, with mostly zero entries, and well behaved. And the output is not the solution but a quantum state holding it. Reading any single entry from that state needs many repetitions, "which would once again kill the exponential speedup." The algorithm remains useful as a component when only a few summary numbers of the solution are wanted, but each of the conditions is a place where a claimed application can fail.

Machine learning on classical data is where these conditions are hardest to meet, because its datasets are large and its outputs are many numbers. Tang's recommendation result was one of several in which an exponential speedup in this area turned out to depend on the assumption that the data could be sampled quickly from a prepared structure, rather than on anything only a quantum computer can do. Given the same fast access, an ordinary algorithm closed the exponential gap. In a 2025 perspective, Google's quantum team made a related point about applications in general: the least developed step is not the algorithm but finding concrete problem instances that are hard for ordinary computers and tied to a real use.

24 — Three conditions a problem must pass
1 · LARGE GAP IN GROWTH FROM STRUCTURE 2 · SMALL INPUT 3 · SHORT, CHECKABLE OUTPUT EXAMPLE PROBLEM factoring RSA-2048 molecular energy unstructured search square root only machine learning on large data often dequantized linear systems (HHL), full solution wanted exponential on paper big compute on small data passes fails
ReadoutFocal detail
Plate 24 — A problem repays a quantum computer only if it has a large gap in growth rate, a small input and a short answer. Factoring and molecular energies pass all three; search, data-heavy machine learning and full solutions of linear systems each fail at least one.

Where no speedup exists

For some tasks a speedup is ruled out outright. Sorting a list by comparing its items needs a number of comparisons that grows like the list length times its logarithm. In 2001 Peter Høyer, Jan Neerbek and Yaoyun Shi proved that the same holds on a quantum computer, so at most a constant factor can be gained. No exponential quantum speedup is known for the large family of hard puzzles called NP-complete, which includes scheduling and many routing problems. For these puzzles, the result of Bennett and colleagues met in Chapter 6 shows that brute-force search can gain only a square root.

Optimization is often named as an early application, but any advantage there is hoped for rather than proved. The quantum approximate optimization algorithm was proposed in 2014. It is a heuristic, a method that often finds good answers without a guarantee, and evidence for its advantage is mixed. In a 2024 study, staff of the bank JPMorgan Chase and of Quantinuum simulated the algorithm without noise on up to 40 qubits, combined with a square-root search, on one hard problem. The algorithm's cost grew as 1.21 to the power of the problem size, against 1.34 for the best classical heuristic, but the square-root part brings the overheads of Chapter 6 with it.

In a study posted as a preprint in December 2024, researchers tested quantum-enhanced heuristics on another standard family of problems. A classical annealing program, which searches by random changes and accepts worse answers less often as it runs, solved instances of up to 128 variables in seconds on a smartphone. The quantum method would have needed weeks, and the authors concluded that current methods may show no quantum advantage at all. The same year, more than sixty authors from industry and universities published a review in Nature Reviews Physics that set out benchmarks and open questions rather than demonstrated advantages.

Kind of problemBest known quantum gainStatus as of October 2026
Factoring and discrete logarithmsexponentialneeds a large error-corrected machine (Chapter 22)
Simulating quantum physics and chemistryexponential for some problemsproblem by problem; classical methods keep improving (Chapter 10)
Unstructured searchsquare rooteaten by overheads on early machines (Chapter 6)
Optimization heuristicsunprovenno demonstrated advantage
Linear algebra and machine learning on large dataexponential only under strong assumptionsseveral cases dequantized
Sorting, databases, spreadsheets, everyday computingnoneno speedup possible or known

Factoring and simulation, the two rows whose exponential gains do not rest on assumptions about the data, share the profile that the three conditions describe. Factoring RSA-2048 takes in 617 digits and returns two numbers of about 309 digits each, which a multiplication checks. Simulating a molecule takes in a description of a few dozen electron orbitals and returns an energy, a single number. In between, both run long computations over registers far too large for any ordinary memory. The phrase big compute on small data describes both of them exactly.

25 — Where quantum gains are known
BEST KNOWN QUANTUM GAIN NONE SQUARE ROOT UNPROVEN EXPONENTIAL UNDER STRONG ASSUMPTIONS EXPONENTIAL sorting and everyday computing unstructured search optimization heuristics linear algebra and machine learning on large data simulating quantum physics and chemistry for some problems factoring and discrete logarithms several dequantized needs a large error-corrected machine the clearest case, and one the guide follows
AmplitudeFocal detail
Plate 25 — Known quantum gains range from none for sorting and everyday computing to exponential for factoring and some simulations of quantum matter. Between them sit square-root search, unproven heuristics and speedups that hold only under strong assumptions about the data.
Test a proposed application against the three conditions

Ask whether the problem has a known large gap in growth rate, and from what structure. Ask how big the input is and how it reaches the quantum computer. Ask how many numbers the answer contains and how many runs reading them takes. A proposal that cannot answer all three is a research question, not an application, and should be planned and funded as one.

+ What this chapter established
  • A claimed quantum speedup is a claim about the best known ordinary method, and Tang's 2018 dequantization of a recommendation algorithm showed that a better ordinary method can appear.
  • A problem repays a quantum computer only with a large gap in growth rate from structure, a small input, and an answer that a few samples can read.
  • Loading a terabyte at the 1 gigabit per second foreseen for a large machine takes over two hours, which rules out speedups on large datasets.
  • Sorting gains nothing, brute-force search gains a square root, optimization heuristics have no demonstrated advantage, and the large known speedups are factoring and the simulation of quantum systems.
Created with Claude (Anthropic).
Educational reference material, not engineering, regulatory or clinical advice. Product and company names referenced are the property of their respective owners.