10 — Simulation

Molecules and materials.

+ The questionMolecules are quantum systems. How big a quantum computer does chemistry that matters need?

Feynman's proposal

In May 1981, at a conference on the physics of computation at MIT's Endicott House, Richard Feynman spoke about what computers could and could not imitate. He had not prepared a formal paper, and his talk was transcribed and published in 1982 as "Simulating physics with computers." The talk's closing remarks contain the phrase most often quoted from it, "nature isn't classical, dammit," followed by the conclusion that a simulation of nature had better be quantum mechanical itself. His argument was the second wall of Chapter 1. Describing many interacting quantum particles takes a number of values that doubles with each particle, so an ordinary computer falls behind exponentially, while a machine built from quantum parts would carry the description in its own state.

Chemistry is the clearest case. The electrons of a molecule set how it bonds, which reactions it speeds up and what color it absorbs, and electrons obey quantum mechanics. Chemists describe the electrons as occupying orbitals, the states an electron can take in the molecule. Each orbital can hold up to two electrons of opposite spin, so a simulation needs two qubits per orbital, one for each spin. A molecule described with 54 orbitals needs 108 qubits before any error correction, and its full description on an ordinary computer would need about 2¹⁰⁸ arrows.

Where approximations fail

Ordinary computers handle most chemistry well, because most molecules can be described by approximations that treat each electron as moving in the average field of the others. The approximations fail where electrons are strongly correlated, meaning that each one's behavior is tied closely to the others'. Strong correlation is common in compounds of transition metals such as iron, molybdenum and copper. Many of the most interesting catalysts in industry and biology are of this kind.

The standard example is the FeMo cofactor, or FeMoco, the cluster of iron, molybdenum, sulfur and carbon atoms at the center of nitrogenase. Nitrogenase is the enzyme that soil bacteria use to turn nitrogen from the air into ammonia at room temperature. Industry makes ammonia at high temperature and pressure. The International Energy Agency puts ammonia production at about 2 % of the world's final energy use, 8.6 exajoules a year, where an exajoule is 10¹⁸ joules. A better understanding of how the enzyme does the job cheaply has been a long-standing goal. Since 2017, FeMoco has been the benchmark molecule for estimates of what a quantum computer needs for chemistry.

The FeMoco bill, and how it fell

In 2017 Markus Reiher and colleagues at ETH Zurich and Microsoft published the first detailed estimate. They modeled FeMoco with 54 electrons in 54 orbitals. Of their designs, the serial one used the fewest qubits. For an accuracy chemists consider useful, it needed about 10¹⁵ T gates on about 111 protected qubits, and at an assumed 10 nanoseconds per T gate the run came to roughly 130 days. With physical qubits erring 1 time in 1,000, the authors estimated about 200 million physical qubits in all.

Later work changed both the model and the method. In 2019 Garnet Chan's group argued for a more representative model of 113 electrons in 76 orbitals, which needs 152 qubits. In 2021 a Google-led team brought the estimated machine for the 2017 model down to about four million physical qubits running for under four days. The 2021 team also counted 3.2 × 10¹⁰ Toffoli gates for the larger model. With a method that another Google-led team published in 2025, that count fell to about 10⁹, a factor of 32.

Solved example: run time from gate count and gate time

Reiher's serial design needs about 1.1 × 10¹⁵ T gates. At 10 nanoseconds each that is 1.1 × 10⁷ seconds, about 127 days. Chapter 6 assumed 170 microseconds per protected Toffoli gate. Taken as a rough time for each T gate, that figure makes the same count take 1.9 × 10¹¹ seconds, about 6,000 years. At 170 microseconds each, the 2025 count of about 10⁹ Toffoli gates for the larger model takes 1.7 × 10⁵ seconds, about two days. Between the two estimates the gate count fell about a millionfold, although they count different gates for different models, while the two assumed gate times differ by a factor of 17,000. Better algorithms cut the cost by more than faster hardware was ever expected to.

26 — How the FeMoco bill fell
10⁸ 10¹⁰ 10¹² 10¹⁴ 10¹⁶ 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 GATE COUNT (T OR TOFFOLI GATES), LOG 54-orbital model 76-orbital model (proposed 2019) algorithms cut the bill more than hardware could 2017 Reiher et al., 54 orbitals: about 10¹⁵ T gates about 200 million physical qubits 2021 Lee et al., same model: 5.3 × 10⁹ Toffolis, about 4 million physical qubits, under 4 days 76 orbitals: 3.2 × 10¹⁰ Toffolis 2025: about 10⁹, a factor of 32 Jan 2026 preprint: classical methods reach chemical accuracy for the 152-qubit model's ground state
AmplitudeReadoutFocal detail
Plate 26 — Estimates for simulating FeMoco fell from about 10¹⁵ T gates in 2017 to about 10⁹ Toffoli gates for a larger model in 2025, mostly through better algorithms. In a January 2026 preprint, a Caltech-led team reported that classical methods had reached the same benchmark energy.

Classical chemistry moved too

Classical methods improved as well. In a preprint posted in January 2026, a team led by Garnet Chan at Caltech reported that classical methods had reached chemical accuracy for the ground-state energy of the 152-qubit FeMoco model itself. The ground state is a system's lowest-energy state, and chemical accuracy is the precision chemists conventionally need to predict how reactions behave. The team worked with the Flatiron Institute, a research institute in New York. They used about 2.8 million processor-core hours of a method called the density matrix renormalization group, together with high-order coupled-cluster calculations, another standard method of quantum chemistry. They converted that cost into seconds to hours of idealized time on the Frontier supercomputer.

As the quantum figure, the team took the 2025 Google-led estimate for the same model: about 4.5 million physical qubits running for 8.6 hours. The authors of that estimate expected newer error-correction methods to shorten it. In its summary, Chan's team wrote that the ground state "can be characterized as one of ranking many competing, but largely simple, states."

The classical result does not settle chemistry: it answers one question, the lowest energy of one model of one cluster. The questions that matter for the enzyme remain open, such as how the reaction proceeds step by step and how the cluster behaves in larger models. But the result fits a broader assessment. In a 2023 study in Nature Communications, authors from universities and from Google and Amazon found no evidence yet of an exponential quantum advantage for generic ground-state chemistry, and they concluded that "it may be prudent to assume exponential speedups are not generically available for this problem." Where an advantage exists, it will come problem by problem, and the classical answer for each benchmark molecule keeps improving.

A 2022 study of cytochrome P450 gives numbers for what problem by problem means. Cytochrome P450 is an enzyme central to how the body breaks down drugs. A team from Google, the drug company Boehringer Ingelheim and the software firm QSimulate placed the limit of reliable classical methods at an active space of about 40 to 43 orbitals. The active space is the set of orbitals that a calculation treats in full detail. For a 58-orbital model just beyond that limit, the team estimated about 4.6 million physical qubits running for 73 hours at a physical error of 1 in 1,000, or about 500,000 qubits for 25 hours if errors fell to 1 in 100,000. Both figures assume the error-correction machinery that Part V describes.

27 — Where classical chemistry stops, for one enzyme
reliable classical methods (cytochrome P450, 2022) 20 30 40 50 60 70 ACTIVE SPACE, ORBITALS reliable classical methods stop here, for this molecule 58-ORBITAL MODEL 4.6 million physical qubits, 73 hours at 1 in 1,000 about 500,000 qubits, 25 hours at 1 in 100,000
AmplitudeReadoutFocal detail
Plate 27 — For cytochrome P450, a 2022 study placed the limit of reliable classical methods at about 40 to 43 orbitals. A 58-orbital model just beyond it would need about 4.6 million physical qubits for 73 hours, or about 500,000 for 25 hours with better qubits.

What has run on hardware so far

Chemistry run on quantum hardware has so far been small or partial. In 2020, Google ran a calculation on 12 qubits that was deliberately chosen to be easy to check classically. The variational quantum eigensolver is a near-term method, meant for machines without error correction. It estimates an energy from many shots, so it runs into the precision cost of Chapter 2. In a 2022 analysis, staff of the software company Zapata Computing and the energy company BP made generous assumptions. Even so, they estimated about two days of measurement for a single energy of methane and about 71 days for ethanol, with dozens to hundreds of such energies needed per calculation.

The largest calculations of 2025 and 2026 split the work. In a May 2026 preprint, researchers from the US medical center Cleveland Clinic, the Japanese research institute RIKEN and IBM treated two protein-ligand complexes of over 11,000 and 12,635 atoms. A protein-ligand complex is a protein bound to a smaller molecule, such as a drug. The quantum processors handled only small fragments, of up to 94 qubits on two IBM Heron processors, while supercomputers handled the rest. The quantum part took 9,200 circuits, 1.3 billion shots and more than 100 hours. The authors wrote that they did "not regard the results reported here as basis of a quantum advantage claim." The work shows how a quantum computer could sit inside a larger simulation, and how many shots even a partial answer costs.

28 — Most of a 12,635-atom calculation ran classically
PROTEIN-LIGAND COMPLEX, 12,635 ATOMS: SUPERCOMPUTERS quantum processors: fragments of up to 94 qubits on two IBM Heron processors THE QUANTUM PART TOOK 9,200 circuits 1.3 billion shots more than 100 hours the authors: "not ... a quantum advantage claim" the quantum part: up to 94 qubits
AmplitudeReadoutFocal detail
Plate 28 — In a 2026 study of protein-ligand complexes of up to 12,635 atoms, quantum processors treated only fragments of up to 94 qubits, at a cost of 1.3 billion shots, while supercomputers did the rest. The size of the whole system is not the size of the quantum part.
Count which part ran on the quantum computer

Announcements of large simulations often give the size of the whole system, such as 12,635 atoms. Ask how many qubits the quantum processor used, which part of the problem they handled, what classical method checked the result, and whether that method could have done the quantum part as well. IBM itself wrote of the 2026 protein study that the method did not yet outperform the best classical approaches.

Ask for the active space and the classical reference

For a chemistry proposal or result, ask how many orbitals and electrons the quantum part treats, because that sets the qubit count. Ask which classical method gives the reference answer, and at what cost, and what accuracy the application needs. A chemistry problem worth a quantum computer is one where the best classical method fails at the needed accuracy within the time allowed, and that failure has to be shown for the specific molecule.

+ What this chapter established
  • Feynman proposed in 1981 that quantum systems be simulated by quantum machines, because their description doubles with each particle; a molecule needs two qubits per orbital.
  • FeMoco, the nitrogen-fixing cluster of nitrogenase, has been the benchmark since 2017, and its estimated quantum cost fell from about 200 million physical qubits to about four million for the same model, while the gate count for a larger model fell by a further factor of 32 by 2025.
  • A 2026 preprint reported that classical methods reached chemical accuracy on the 152-qubit FeMoco model, and a 2023 study advised against assuming exponential speedups for generic ground-state chemistry.
  • Hardware results so far are small or partial, such as fragments of up to 94 qubits inside a 12,635-atom protein simulation, and their authors make no claim of advantage.
Created with Claude (Anthropic).
Educational reference material, not engineering, regulatory or clinical advice. Product and company names referenced are the property of their respective owners.