18 — Control and readout

The signal chain of one qubit.

+ The questionHow does a pulse made at room temperature become a gate, and a qubit's state become a bit?

Reading without touching

A transmon cannot be wired to anything that would carry its energy away, yet its state must be read in under a microsecond. The answer is to read it indirectly. Alexandre Blais and colleagues proposed the method in 2004, and Robert Schoelkopf's group at Yale demonstrated it in 2004 and 2005. Each qubit is coupled to its own small microwave resonator, a circuit that rings at one frequency. That frequency shifts slightly depending on whether the qubit holds 0 or 1. A weak microwave tone sent past the resonator comes back carrying the shift, while the qubit itself absorbs almost nothing. Because the tone is tuned to the resonator and not to the qubit, the reading leaves the qubit in the state it reports, as Chapter 2 requires of a measurement.

The method, called dispersive readout, turns the reading of a qubit into a problem every radio engineer knows: detecting a faint signal against noise. On Willow, the readout resonators sit near 4.5 GHz, below the qubits at about 6 GHz, and each tone lasts 250 to 480 nanoseconds. The signal that comes back is extremely faint, and every stage after the chip exists to make it large enough to read before the qubit changes.

The chain, end to end

Seen as an instrument, a quantum computer runs the same chain as any measuring system: sense, condition, digitize, compute, connect and decide. For a qubit the chain runs in a loop, because what is decided in one cycle sets the pulses of the next.

StepWhat it does for a qubitTypical parts
Sensethe resonator shifts its frequency with the qubit's stateon-chip resonator, about 4.5 GHz on Willow
Conditionthe faint readout signal is amplified with little added noise, and the drive pulses are attenuated and filtered on the way downparametric amplifier near 10 millikelvin, transistor amplifier at about 3 K, isolators, attenuators and filters
Digitizefast converters sample the returning signal and generate the outgoing pulsesanalog-to-digital and digital-to-analog converters at room temperature
Computeeach shot is reduced to a point and classified as 0 or 1, and the checks of the code are decodedfield-programmable gate arrays, workstations, custom chips
Connectresults move between control units and to the decoder fast enough to keep uplow-latency links
Decidethe next pulses are chosen, including any correctionthe control system's sequencer
48 — The signal chain of one qubit, as a loop
ROOM 3 K 10 mK SENSE qubit resonator, about 4.5 GHz on Willow, at about 10 mK CONDITION parametric amplifier near 10 mK, transistor amplifier at about 3 K; attenuators and filters on the way down DIGITIZE converters at room temperature COMPUTE classify each shot as 0 or 1; decode the checks CONNECT low-latency links DECIDE choose the next pulses, including corrections drive pulses, attenuated what is decided in one cycle sets the next
Control pulseReadoutFocal detail
Plate 48 — Control and readout of a qubit follow the instrument chain of sense, condition, digitize, compute, connect and decide, run as a loop: what the decoder decides in one cycle sets the pulses of the next.

Control-system makers sell the room-temperature part of the chain as instruments. Quantum Machines describes generating pulses directly from digital waveforms at frequencies up to 10.5 GHz. Zurich Instruments quotes a feedback delay of 350 nanoseconds for a controller that drives and reads six qubits. Qblox sells racks of about 20 qubits each, and Keysight has installed a control system for more than 1,000 superconducting qubits in Japan. All are company figures, and they show how much ordinary instrument engineering a quantum computer contains.

Making a gate

A gate starts as numbers. Software computes the shape of a pulse, a converter turns that shape into a microwave waveform, and the waveform travels down the attenuated lines of Chapter 17. On Willow a single-qubit pulse lasts 25 nanoseconds, and its shape matters. In 2009 Felix Motzoi, Jay Gambetta and colleagues showed that adding a second component to the pulse keeps a short pulse from leaking the transmon into level 2. The second component is proportional to how fast the first is changing, and in their analysis it reduced the error by about a factor of ten. Pulses of this kind, called DRAG pulses, are now standard. Two-qubit gates on Willow are controlled-Z gates between neighbors, and each takes 42 nanoseconds.

Amplifying the answer

The returning readout signal is weaker than the noise any ordinary amplifier adds. The first amplifier therefore sits on the coldest plate and works near the limit that quantum physics sets for added noise. Such parametric amplifiers boost the signal with a superconducting circuit fed by a strong microwave tone, called the pump, which supplies the energy for the gain. A 2015 design from MIT Lincoln Laboratory and Berkeley spread the amplification along a line and could read 20 qubits at once. Willow's paper describes a newer compact parametric amplifier design that replaced the type used on earlier Google chips.

The second amplifier is a cooled transistor of the kind used in radio astronomy, and it sits at about 3 K. Components that let signals pass in one direction only, called isolators, keep the transistor's noise from flowing back to the chip. Several qubits share each readout line and amplifier: their resonators are built at slightly different frequencies, so one burst containing several tones reads them all at once, and the electronics separate the answers by frequency.

Solved example: why the first amplifier must be quantum-limited

An amplifier's added noise can be stated as a noise temperature, the temperature at which a resistor would produce the same noise, or as a number of photons. A phase-preserving amplifier amplifies a signal by the same factor whatever its phase. At 4.5 GHz, the least noise such an amplifier can add corresponds to about 0.11 K, or half a photon. A cooled transistor amplifier with a noise temperature of 1.5 K, a manufacturer's figure, adds about 7 photons. The signal arrives with half a photon of noise of its own, the least that quantum physics allows. With the transistor first, the total noise is therefore about 7.5 photons. With a quantum-limited amplifier in front, the total is about 1, half a photon from the signal and half from the amplifier, because the amplifier's gain makes the transistor's noise small by comparison. For the same signal-to-noise ratio, the reading must therefore last about 7.5 times longer without the parametric amplifier. Willow's readings of 250 to 480 nanoseconds would become about 1.9 to 3.6 microseconds, during which a qubit with a T1 of 68 microseconds decays 2.7 to 5.1 % of the time, against 0.37 to 0.70 % as built.

49 — Why the first amplifier must be quantum-limited
NOISE, PHOTONS READING TIME DECAY DURING READING TRANSISTOR AMPLIFIER FIRST QUANTUM-LIMITED AMPLIFIER FIRST 0 2 4 6 8 0 1 2 3 4 µs 0.5 about 7 from the transistor about 7.5 in all 1.9 to 3.6 µs 2.7 to 5.1 % 0.5 + 0.5: about 1 250 to 480 ns, as built 0.37 to 0.70 % decay during readout kept below 1 % at 4.5 GHz: half a photon (about 0.11 K) is the least an amplifier can add; transistor noise temperature 1.5 K same signal-to-noise ratio in both rows, so reading time grows with total noise; T1 = 68 µs
Noise and errorReadoutFocal detail
Plate 49 — A cooled transistor amplifier adds about 7 photons of noise at 4.5 GHz, so readings would last about 7.5 times longer and a qubit would decay during 2.7 to 5.1 % of them. A quantum-limited amplifier in front keeps readings at 250 to 480 ns and decay below 1 %.

From a voltage to a bit

At room temperature, the amplified tone is sampled, and its phase and amplitude are reduced to a single point on a plane. Readings of qubits in 0 cluster in one cloud, and readings of qubits in 1 cluster in another. A dividing line between the clouds turns each point into a bit. Errors come from noise, which makes the clouds overlap, and from qubits that decayed during the reading and landed between the clouds. Small laboratory devices have read quickly and accurately: a 2024 ETH Zurich study reached a readout error of 0.25 % in 100 nanoseconds, and a 2025 RIKEN study read four qubits at once in a little over 50 nanoseconds. Error correction needs every qubit of a large chip read at once. Reading them all together is harder, and Willow's readout error, measured with all its qubits read at once, is 0.77 %.

The bits then go to the decoder of Chapter 15. Willow's paper reports a real-time test on a second Willow processor, with 72 qubits. In that test the decoder ran on a 64-core workstation, linked to the control system over low-latency Ethernet, and returned answers in about 63 microseconds. In 2025 IBM reported a decoder on a programmable logic chip that processed twelve cycles of check results for its own codes in about 480 nanoseconds on average. That time was measured on recorded data, not on a running machine, and IBM's staff reported it in a preprint. The decoder performs the compute and decide steps of the chain, and its delay limits how fast a computation can proceed when it needs corrected results.

Read readout figures for the whole chip at once

A readout error quoted for one qubit read alone on a small device describes what the method can do, not what a processor achieves when all its qubits are read together and their tones pass through the same amplifier. Ask whether a figure was measured simultaneously across the chip, and with what reading time.

Keeping the chain calibrated

No two transmons are alike, as Chapter 2 noted, and their parameters drift as defects move. Every pulse must therefore be calibrated, and the calibrations depend on each other. A qubit's frequency must be known before its pulse can be tuned, and its pulse before a two-qubit gate. In 2018 a Google team organized calibration as a graph of such dependencies, each with its own time before it must be repeated. The team gave as an example a pulse that must turn the arrow to within one ten-thousandth of a radian.

For every qubit, a full calibration runs a chain of such experiments, from finding the qubit's frequency and the strength of a pulse that flips it to setting the dividing line between its readout clouds and tuning each two-qubit gate with each neighbor. On a chip of a hundred qubits the graph grows large. Until recently, recalibrating meant stopping the computation.

50 — Calibration as a graph of dependencies
QUBIT FREQUENCY FLIP-PULSE STRENGTH PULSE SHAPE (DRAG) READOUT DIVIDING LINE TWO-QUBIT GATE WITH EACH NEIGHBOR each step has its own time before it must be repeated (Google, 2018) CHECK RESULTS OF THE RUNNING CODE LEARNING PROGRAM adjusts more than 1,000 settings while the code runs (2026) calibrated pulses run the code calibration moves into the control loop stability under drift improved 3.5-fold; distance-7 memory: 7.72 errors in 10,000 cycles
Control pulseLogical qubitReadoutFocal detail
Plate 50 — Every pulse must be calibrated, and each calibration depends on others, from the qubit's frequency to each two-qubit gate. In 2026 Google used the check results of a running code to adjust more than 1,000 settings while it ran.

In July 2026 Google reported a way to calibrate without stopping. Google's team used the stream of check results from a running error-correction code as the input to a learning program, which adjusted more than 1,000 control settings while the code ran. Stability against drift that the team injected on purpose improved 3.5-fold, and the distance-7 memory reached 7.72 errors in 10,000 cycles. Google's method moves calibration from a maintenance task into the control loop itself, which is where an instrument engineer would expect it.

Map a qubit's signal chain like any instrument

For each qubit, list the parts from pulse generator to decoder with the gain, noise, delay and heat of each, as for any sensing system. Then check three budgets: noise at the first amplifier, which sets the reading time; delay around the loop, which sets how fast corrections arrive; and heat at each cold stage, which sets how many chains fit in one refrigerator. Instrument engineering decides how many qubits work, not only how many exist.

+ What this chapter established
  • A transmon is read through a resonator whose frequency shifts with the qubit's state, so the reading becomes the detection of a faint microwave tone lasting 250 to 480 nanoseconds on Willow.
  • The control and readout of a qubit follow the instrument chain of sense, condition, digitize, compute, connect and decide, run in a loop, and much of it is built from commercial instrument hardware.
  • A quantum-limited amplifier at the coldest stage lets readings be about seven and a half times shorter than with a cooled transistor amplifier alone, which keeps decay during readout below 1 %.
  • Calibration keeps every pulse matched to its drifting qubit, and in 2026 Google moved it into the running computation, adjusting over 1,000 settings while the code ran.
Created with Claude (Anthropic).