What changed in 2025 and 2026.
+ The questionWhich results of 2025 and 2026 moved the field, measured by the yardsticks this guide has built?
Three yardsticks, not one headline
A two-qubit gate that fails about 8 times in 100,000, a protected memory that fails about 46 times in a million cycles, and a quantum computation matched by graphics processors in 37 minutes: the results of 2025 and 2026 moved in different directions at once. A scorecard kept by company would hide those differences, because each company reports the figures that show its own machine at its best. This chapter keeps the scorecard by metric instead, using the yardsticks of the earlier chapters. They are the error of a physical two-qubit gate, the error of a protected qubit and the slope Λ behind it, and claims of advantage together with the classical replies they drew. Each figure is labeled by where it was measured and in what kind of source, because a pair of qubits in a laboratory and the median of a whole chip are different measurements.
Physical gates
The plate below lists the best two-qubit gates of the period, from lowest error to highest. Each is labeled with what it was measured on and the kind of source that reported it. The first was measured on a single pair of ions; the rest are averages or medians across many qubits.
Two patterns stand out. First, ions and superconducting chips ran gates with errors below 0.2 % across whole machines, and a laboratory array of atoms matched them. The kind of qubit therefore no longer decides who has the best gates, as Chapter 19 argued. Second, the best single pair beat the best whole machine by about a factor of ten. That is the usual distance between what a method can do and what a processor achieves when every qubit runs at once.
The plate also leaves out two things that matter as much. One is speed: Helios's gates take about 70 microseconds and Willow's 42 nanoseconds, a factor of more than a thousand, which Chapter 19 turned into run time. The other is the kind of average. Companies quote medians or means over pairs of qubits. Some quote an error averaged over all inputs, while others quote the Pauli error, which for a two-qubit gate is five fourths as large, as Chapter 4 showed for Willow's 0.33 % and 0.41 %. Two figures that differ by a fifth may therefore describe the same gate.
Gate quality is often counted in nines: a fidelity of 99.9 % has three and 99.99 % has four. At an error of 1 in 1,000 per gate, the chance that a run of N gates has no error is 0.999 raised to the power N, which falls to one half at N = 693. At 1 in 10,000 it falls to one half at N = 6,931, and at the Oxford Ionics figure of 8.4 in 100,000, at about 8,250. A fourth nine therefore buys ten times longer circuits without error correction. Inside a surface code it buys more, because Λ is roughly the threshold divided by the physical error (Chapter 15). A tenfold lower error raises Λ about tenfold, so each protected qubit needs fewer physical qubits.
Protected qubits
Error correction produced the year's most important results and its most confusing headlines. The table sorts them by the rungs of Chapter 16, from memories corrected every cycle to codes that only detect errors and discard the runs that show them.
| Result | Code and scale | Figure | Rung |
|---|---|---|---|
| Google Willow, Dec 2024 | surface code, distance 7, 101 qubits | 0.143 % per cycle; Λ = 2.14 | corrected every cycle |
| Google Willow, learned calibration, 2026 | same code, on a Willow processor | 0.077 % per cycle | corrected every cycle |
| Zuchongzhi 3.2, Dec 2025 | surface code, distance 7 | Λ = 1.40 | corrected every cycle |
| Quantinuum Helios, Sep 2026 | distance-6 code, 2 logical qubits in 20 ions | 0.0046 % per cycle | corrected, preprint |
| Harvard, MIT and QuEra, Nov 2025 | surface code at distances 3 and 5, four rounds, on an array of up to 448 atoms | 0.62 % per round at distance 5 | corrected for a few rounds |
| Atom Computing, Jun 2026 | toric code at two sizes, up to 90 cycles | the larger code erred less over short runs | corrected, preprint |
| IBM and University of Chicago, Jul 2026 | 70 encoded qubits on 97 | errors ten times below physical, after discarding runs | detected, preprint |
| Infleqtion, Sep 2026 | 30 logical qubits on 80 atoms, distance 2 | no logical error rate published | detected, company release |
Judged by code distance and by errors shown to fall as the code grows, the leader on the top rung is still Google's distance-7 memory. With learned calibration it reached 7.7 errors in 10,000 cycles in 2026. On Google's own roadmap, the next milestone is one error in a million, about 770 times lower. Quantinuum's distance-6 code erred 4.6 times in 100,000 cycles, the lowest logical error per cycle in the table above. That figure is for two logical qubits in a small code, and like Google's memory it was reached without the T gates of Chapter 4. Both remain many factors of ten away from the 1 in 10¹⁵ of Chapter 13.
What moved the top rung was mostly control and design rather than new kinds of chip. Google's 2026 result came on a Willow processor tuned by a learning program that adjusted more than 1,000 settings, and the team credits the program with about 20 % lower logical error than expert calibration alone. The Chinese team's result rested on removing leakage, the escape to level 2 of Chapter 12, with microwave pulses alone. The Harvard team's decoders used the knowledge of which atoms had been lost, and Quantinuum's compact code held two protected qubits in 20 ions. Each gain came from treating the machine as a whole system, which is the instrument view of Part VI.
Logical errors are quoted per cycle, per round, per operation or per logical qubit. They come from codes of different distances, decoded in real time or afterward, with or without discarded runs. A figure from one row of the table above cannot be set against another until all of these are converted. A count of logical qubits from the lower rungs says nothing about the slope Λ.
The slope Λ is the ratio of the logical errors at two code distances that differ by two, one step apart, so it says how fast a code improves as it grows. A thousandfold cut needs enough steps for Λ, multiplied by itself once per step, to reach 1,000. At 2.14 that takes ten steps, since nine give only about 940, and at 1.40 it takes twenty-one. Starting from distance 7, Willow's slope reaches the thousandfold cut at distance 27, a patch of 1,457 qubits. Zuchongzhi 3.2's slope needs distance 49, a patch of 4,801 qubits, more than three times as many for the same protection.
Scale, advantage and the classical side
Arrays of qubits grew faster than the machines that compute with them. In 2025 a Caltech team held more than 6,100 atoms, with long coherence but no two-qubit gates, and a June 2026 preprint reported trapping 11,000 atoms loaded at random (Chapter 19). As of October 2026 IBM's largest chip remained the 1,121-qubit Condor of 2023 (Chapter 20), and D-Wave's annealer has more than 4,400 qubits of a different kind, by the company's count (Chapter 19). The claims of advantage that Chapter 11 examined moved toward results that can be checked. They included certified randomness in March 2025, Google's Quantum Echoes in October 2025 and IBM's three claims of 30 July 2026, one of them backed by a certified bound on its fidelity.
The classical side answered quickly. About two weeks after IBM's claim, a team at the Singapore University of Technology and Design and NVIDIA reported in a preprint that it had simulated the 70-qubit circuit on 256 graphics processors in 37.3 minutes. The quantum machine had taken about 15 minutes. In September 2026 the classical factoring record moved twice in sixteen days, first to RSA-260 and then to RSA-896. Both factorizations ran on graphics processors using sieve software rewritten with AI coding tools, as Chapter 1 described. Neither record brings RSA-2048 within reach of classical machines, which would need tens of billions of times more work, but both show that the classical baseline in every comparison keeps moving.
Estimates, programs and honors
The estimates of what useful machines need also changed. In February and March 2026, three teams posted preprints with designs that cut the qubits needed to break public-key cryptography, the family of methods to which RSA belongs. Two of them reorganize the machine: Iceberg Quantum used codes that need long-range links, and a team from the start-up Oratomic, Caltech and Berkeley used reconfigurable neutral atoms. A Google-led team kept the hardware assumptions of the designs by Craig Gidney of Google Quantum AI and targeted the elliptic-curve systems used in cryptocurrencies. Chapter 22 sets these designs against the bill. The US government also tied funding to public tests of machines. Its Department of Energy announced the Quantum Genesis initiative in June 2026. In September it opened a competition for machines with at least 100 logical qubits able to run hundreds of millions of fault-tolerant operations, and applications are due on 19 October 2026.
The field's foundations were honored in the same period. The 2025 Nobel Prize in Physics went to John Clarke, Michel Devoret and John Martinis. It was announced on 7 October 2025 and honored the 1985 Berkeley experiments of Chapter 17, which showed a whole circuit behaving like an atom. In March 2026 the 2025 A.M. Turing Award went to Charles Bennett of IBM and Gilles Brassard of the University of Montreal. Their work from the 1970s to the 1990s established much of quantum information science, including quantum teleportation, which moves a qubit's state from one place to another using an entangled pair and an ordinary message.
For each new result, record the metric, the value, the date, the kind of source and the scale at which it was measured, from one pair of qubits to a whole chip or one protected qubit. Compare it only with entries on the same row. Update the classical baseline beside every claim of advantage, and add a result to the protected-qubit rows only once its rung is clear.
- Two-qubit gates below 0.2 % now run across whole machines of ions and superconducting circuits, and on a laboratory array of atoms, and the best pair of ions reached 8.4 errors in 100,000, about ten times better than any whole machine.
- On the top rung of error correction, Google's distance-7 memory reached 7.7 errors in 10,000 cycles and a Chinese team reached Λ = 1.40, while many larger logical-qubit counts came from codes that only detect errors.
- Claims of advantage moved toward results that can be checked, and classical replies kept pace: IBM's July 2026 circuit was simulated on graphics processors about two weeks later, and the classical factoring record moved twice in September 2026.
- New 2026 designs cut the qubits needed to break public-key cryptography, the US Department of Energy set a public test of 100 logical qubits, and the Nobel and Turing prizes honored the field's foundations.
Let's Talk