+ Part IV · Noise
What scrambles a qubit, and how errors add up.
Willow's qubits hold their state for about 68 microseconds on average, and about once an hour something disturbs many of them at once. Part IV measures the noise behind the objection Landauer raised in 1994. Chapter 12 sets out what scrambles a qubit's arrows and how fast, from defects in the chip's materials to particles from space. Chapter 13 shows why errors that are rare for one operation become certain over a long computation, and why a quantum computer cannot simply keep backup copies.
What scrambles a qubit.
+ The questionWhat does noise do to the arrows, and how fast?
Two ways to lose a qubit
A Willow qubit left in the state 1 decays to 0 after about 68 microseconds on average. Google's 2024 error-correction paper gives that average across the whole chip. A single cycle of Willow's error correction takes 1.1 microseconds. The loss of the 1 state is called energy relaxation, and its average time is written T1. In the picture of arrows, relaxation shrinks the arrow for 1 and lengthens the arrow for 0, as the circuit gives its energy to its surroundings.
The second kind of loss leaves the energy unchanged and affects only the directions of the arrows. Small random shifts in the qubit's frequency make the arrow for 1 turn slightly faster or slower than expected, so that after a while the relative direction of the two arrows is no longer known. This loss of direction is called dephasing, and the time over which the direction is lost is written T2. Relaxation also contributes to the loss of direction, so T2 can be at most twice T1. A qubit that has lost its phase still reads 0 or 1 with the right odds, but it no longer interferes as intended, and interference is all that a quantum algorithm uses. Google's paper gives a mean T2 of 89 microseconds for Willow. On Google's previous error-correction chip, of 2023, T1 and T2 were 20 and 30 microseconds.
T1 and T2 are together called the qubit's coherence times, and both are measured with the tools of Chapters 2 and 4. For T1, a qubit is prepared in 1, left alone for a chosen delay and then read. The fraction still found in 1 is plotted against the delay, and the fall of that curve gives T1. For T2, a Hadamard gate spreads the qubit over both levels, a delay follows, and a second Hadamard makes the arrows interfere, so the interference fringes fade as the delay grows and the directions drift apart. Refocusing pulses added in the middle of the delay undo slow drifts in frequency: each pulse flips the qubit, so the extra turn that a slow drift gives the arrows before the pulse is undone by the same drift after it. Google quotes the version with a train of such pulses, called CPMG after the initials of its inventors.
The calculation uses e, a constant of about 2.718 that describes any steady decay. The chance that a qubit with a T1 of 68 microseconds relaxes during a time t is 1 minus e to the power of minus t divided by 68 microseconds. During a 25-nanosecond single-qubit gate the chance is about 0.037 %. During a reading of 250 to 480 nanoseconds it is 0.37 to 0.70 %, close to Willow's measured readout error of 0.77 %. During one 1.1-microsecond cycle of error correction it is about 1.6 %. Reading is the longest step in each cycle: on Google's 2023 chip it took 500 of the 921 nanoseconds, and resetting took 160. A qubit reaches a 1 % chance of having relaxed after only about 0.68 microseconds, less than one cycle.
A coherence time stated alone may describe the best qubit on one chip on one day. Processors are limited by their worst qubits, because a computation uses all of them, and by drift, because defects change over hours. Ask for the mean or median across the chip, the spread, and how much it varies over time.
The surroundings take a reading
Every loss of this kind has the same root, the effect met in Chapter 3. The arrows of a qubit interfere only while nothing records which outcome it is in. Any interaction that leaves a trace of the qubit's state in its surroundings acts like a partial reading that nobody asked for. The trace may be an emitted photon, a jostled defect or a shifted charge, and once it exists the arrows lose their ability to interfere. The general name for this loss is decoherence, and fighting it is most of the engineering of a quantum computer.
In superconducting chips the leading causes are known. Atom-sized defects in the thin oxide layers and surfaces of the circuit behave as tiny two-level systems of their own, which act like small, unwanted qubits. When a defect's frequency sits near the qubit's, the defect absorbs the qubit's energy. These defects drift in frequency, so a qubit's T1 changes over time, and a 2018 Google study tracked those changes. Stray microwave photons, magnetic flux noise and unpaired electrons in the superconductor add their share. Every gate on a neighbor also risks a little crosstalk. Willow's team forecasts where the defects sit in frequency and moves each qubit's operating frequency away from them before a run.
Leakage out of the two levels
A transmon has levels above 1, and an imperfect pulse or a stray excitation can push it into level 2 or higher. A qubit in that state is said to have leaked. Leakage is worse than an ordinary error, because the error-correction schemes of Part V are built to catch flips and phase turns between 0 and 1, not escapes from the two levels. A leaked qubit can also spread errors to its neighbors for many cycles. In Willow's code, data qubits hold the information and measurement qubits check the data qubits. Willow resets its measurement qubits after each reading, which clears their leakage, and periodically moves any leakage from the data qubits into dedicated qubits that are reset in turn. Four of the 101 qubits in its largest code do nothing else.
Bursts from space
Some errors strike many qubits at once. In a 2022 study, a Google team watched a 26-qubit chip and saw a burst on average every ten seconds. In each burst, errors spread across the chip and faded over about 25 milliseconds, and in the largest events nearly every qubit erred. The cause was high-energy radiation from cosmic rays and from traces of radioactivity in the surroundings. The radiation deposited energy in the chip and broke up the electron pairs that carry the superconducting current. A Beijing group reported in 2025 that detectors inside its refrigerator had caught muons arriving at the same moments as correlated errors on its chip. Muons are particles produced by cosmic rays in the upper atmosphere.
A 2024 design trick called gap engineering made the qubits largely insensitive to such broken pairs, by making the superconductor on the two sides of each junction slightly different. In Willow, the remaining correlated bursts came about once an hour, roughly every 3 billion cycles, and their cause was uncertain.
Bursts matter more than their rarity suggests. Error correction assumes that errors strike qubits independently and rarely together, and a burst that hits dozens of neighbors at once breaks that assumption. Willow's simplest codes protect against only one kind of error and can therefore reach very low error rates, but because of these bursts they stopped improving near one error in 10¹⁰ cycles. A computation of billions of steps will meet such bursts, so the hardware must suppress them and the codes must survive the ones that remain.
Better materials, one qubit at a time
Coherence times have risen steadily. Willow's mean T1 is about three and a half times that of Google's 2023 chip. In 2025 a Princeton team reported transmons built from tantalum on silicon with a T1 of up to 1.68 milliseconds, about 25 times Willow's mean, together with single-qubit gate fidelities of 99.994 %. The 1.68 milliseconds was the best single device among those measured, not the average of a working processor, and bringing such materials into chips of hundreds of qubits, each wired, coupled and controlled, takes years.
Longer coherence helps with everything the later chapters describe, because each gate and each reading then uses a smaller fraction of the time a qubit can hold its state. Other kinds of qubit sit at very different points. In a 2021 laboratory record, a single trapped ytterbium ion held its phase for an estimated 5,500 seconds, about an hour and a half, and in 2025 an array of atoms at Caltech kept their phase for about 12.6 seconds. Chapter 19 shows why the slower gates of ions and atoms offset much of that advantage.
When evaluating a processor, ask how often it is recalibrated and how much its error rates drift between calibrations, how leakage is detected and removed, and how often correlated bursts of errors occur and what limits them. These three effects, not the average error rate, set the floor that error correction can reach. Chapter 15 shows that this floor decides how large a protected memory can usefully be.
- Energy relaxation shrinks a qubit's arrow for 1 and dephasing scrambles the relative direction of its arrows, and on Willow their times, T1 and T2, average 68 and 89 microseconds.
- With a T1 of 68 microseconds, about 1.6 % of qubits relax during one 1.1-microsecond cycle, and about 0.4 to 0.7 % during a single reading.
- Decoherence is an unintended reading by the surroundings, caused in superconducting chips by material defects, stray photons and crosstalk, and leakage above the two working levels adds a further kind of error.
- Bursts of errors strike many qubits at once, every ten seconds or so on a chip studied in 2022, where cosmic rays and radioactivity caused them, and about once an hour on Willow, built with gap engineering, where their cause was uncertain; they set a floor on what codes can reach.
Let's Talk